7
SKOPE SCS Connect Electronic Controller
Application Procedures
Technicians’ Manual
Note: Only inputs connected to, or components directly controlled by, the SCS Connect
controller will be displayed upon the Home Screen. For example, if the condenser fan is
directly driven from the compressor then the condenser fan icon will not be displayed on the
home screen.
Events (Alarms or Faults) can be accessed directly from
the home screen. This allows you to view details about
the fault, as well as the history of the recorded faults.
Tap on any component showing the small yellow triangle
symbol to view the current event.
From the details screen you can see the possible cause,
along with a current reading and any parameters that may
be related to the fault.
You can view the event history for that component by
tapping the yellow triangle beside Event History.
App Menu The menu (three horizontal bars on the top right hand side) provides access to the first level
of the app’s functions.
Table 2: App menu items
Menu item Description
Home Returns to the home screen
Output control Output control screen
Edit parameters Access the parameters for editing
Load parameter file Select a parameters file from local or cloud storage
Statistics Review the controller’s statistics
SCS info Details of the SCS controller
SCS setup Set up and change asset information
Disconnect Disconnect the app from the controller
Settings App settings
IMPORTANT
After connecting to or modifying any controller, always disconnect
your device from the controller to confirm all changes.
IMPORTANT
Always power cycle the cabinet if:
• changing time-based parameters.
• updating a significant number of parameters.
• updating the firmware.
App menu