Skipper CD401 LR Fiche technique

CD401 LR Speed Log Repeater
Operation and Installation Manual
EML224 Compact
Document no: DM-R004-SB
Edition: 2013-11-05
Rev: 1.13
for SW version 1.12 to 1.15
SKIPPER Electronics AS Telephone:+47 23 30 22 70
Enebakkveien 150 Telefax: +47 23 30 22 71
P. O. Box 151, Manglerud E-mail: support@skipper.no
0612 Oslo, Norway Co. reg. no: NO-965378847-MVA
www.skipper.no

Operation and Installation CD401LR
Edition: 2013-11-05 Rev: 1.13Page 2 of 28
OPERATION AND
INSTALLATION MANUAL
November 2013
Edition 2013-11-05 Sw. 1.12 - 1.15

Operation and Installation CD401LR
Edition: 2013-11-05 Rev: 1.13 Page 3 of 28
LRSpeed Log
Repeater
COMPACT VERSION
Weitergabe sowie vervielfältigung dieser
unterlage, verwertung und mitteilung ihres
inhaltes nicht gestattet, soweit nicht ausdrücklich
zugestanden. Zuwiderhandlungen verpichten zu
schadenersatz.
Toute communication ou reproduction de ce docu-
ment, toute Exploitation ou communication de ou
son contenu sont interdites, sauf
Autorisation expresse. Tout manquement à
cette règle est illicite et Expose son auteur au
versement de dommeges et intèrèts.
Copying of this document, and giving it
to others and the use or communication
of contents thereof, are forbidden without
express authority. Offenders are liable to the
payment of damages.
Sin nuestra expresa autorización, queda
terminantemente prohibida la Reproducción
total o parcial de este documento, asì
como su uso Indebido y/o su exhibición o
comunicación a terceros. De los infractores
Se exigirá el correspondiente resarcimiento
de daños y perjuicios.
Electronics AS

Operation and Installation CD401LR
Edition: 2013-11-05 Rev: 1.13Page 4 of 28
Communicating with us
If you need more information, support or other assistance from us, do not
hesitate to contact us:
SKIPPER Electronics AS
Enebakkveien 150
P. O Box 151
NO-0612 Manglerud, Norway
Phone: + 47 23302270, Fax: + 47 23302271
E-mail Support@skipper.no
Software updates and technical support
Find us on the world wide web: www.skipper.no
Your Feedback is appreciated
If you nd errors, misspellings or poorly explained sections in this document,
please do not hesitate to contact us at:
support@skipper.no
Electronics AS

Operation and Installation CD401LR
Edition: 2013-11-05 Rev: 1.13 Page 5 of 28
OVERVIEW
Content of the manual
___________________________________________________________________________
Terminology
Terms, units and abbreviations used in this manual.
Introduction
This part introduces you to the elements of the electromagnetic speed log
(EML) system.
Chapter 1 – Physical installation
Correct installation of the system will ensure problem free service for many
years. This section explains the main steps to get your system working.
Chapter 2 – Setting up the Compact Repeater
The Compact display is a exible, yet intuitive display allowing data to be
displayed in a user freindly way. It is also a primary system and can be integrated
into the navigation system as regulation stipulate. This chapter explains how
to set up the unit.
Chapter 3 – Routine operation
Once the system is installed and operational, the user can change the screen
to show the data of interest at any particular time. This section explains the
basic operation of the system.
Chapter 4 – checking your system
It is a good idea to verify your systems performance from time to time. This
chapter describes how to check interfaces and other issues. In the event of
mailfunction, this is a good place to start for trouble shooting.
Appendix 1 – Background information
Here you will nd more details of how the system works and which factors are
inportant to know when using it.
Appendix 2 – Formats
This section describes the inputs accepted byt the compact display in this
conguration
Appendix 3 - Sending the system for repair
In the unfortunate case of a failure that requires a factory repair, the described
return sequence should be followed.

Operation and Installation CD401LR
Edition: 2013-11-05 Rev: 1.13Page 6 of 28
Appendix 4 - Other options with the Speed log repeater
The Compact can be used in a number of different system both as a repeater
and a speed log. This section explains what is available and how to activate the
options. The compact also contains a diagnostics port, from which the user can
obtain diagnostic information using hyperterm.

Operation and Installation CD401LR
Edition: 2013-11-05 Rev: 1.13 Page 7 of 28
TABLE OF CONTENTS
Overview 5
Content of the manual 5
Terminology 9
Terms used in this manual 9
Introduction 10
The RL speed Log Repeater 10
Chapter 1 11
Physical installation 11
The Dimming Inputs 12
Chapter 2 13
Setting up the Compact Display 13
Principles 13
Run screens 13
Menu screens 14
Activating the Runtime Displays 14
Conguring of data screens 15
Menu Diagram 16
Changing of the baud rate 18
Demo mode 18
Chapter 3 19
Routine Operation 19
Run screens 19
Chapter 4 20
Maintenance 20
Routine maintenance 20
Checking your version 20
Firmware upgrade 20

Operation and Installation CD401LR
Edition: 2013-11-05 Rev: 1.13Page 8 of 28
Appendix 1 21
Spesication and mechanical drawings 21
System full specication 22
User denes inputs/outputs 22
Accepted NMEA (IEC61162-1) formats 22
Appendix 2 24
Accepted formats 24
Accepted NMEA0183 (IEC61162-1) messages 24
Appendix 3 25
Sending the system for repair 25
Appendix 4 26
Other options with the compact display 26
Compact options 26
Changing the system/ adding options 26

Operation and Installation CD401LR
Edition: 2013-11-05 Rev: 1.13 Page 9 of 28
TERMINOLOGY
terms used in this manual
______________________________________________________________
units
Unless otherwise stated, all values shown on the display are as follows:
Distance Nautical Miles (nm)
Speed Nautical Miles per hour (Kn)
Speed Pulses per Nautical Mile (P/nm)
Temperature Degrees Celsius (oC)
abbreviations
In addition, the following symbols are used on the Runtime screens
TPDaily Trip (in nm)
TLTotal measured distance travelled
oDegrees Centigrade
STW Speed Through Water
TRIP Text for Trip/Total
SOG Speed Over Ground
TEMP Text for TEMPerature
In Menu / Setup screens the following abbreviations are used:
STWWL Speed Through Water – Water track – Longitudinal value
STWWT Speed Through Water – Water track – Transversal value
SOGBL Speed Over Ground – Bottom track – Longitudinal value
SOGBT Speed Over Ground – Bottom track – Transversal value
SOGBA Speed Over Ground – Bottom track – Aft value

Operation and Installation CD401LR
Edition: 2013-11-05 Rev: 1.13Page 10 of 28
INTRODUCTION
the lr speed log repeater
______________________________________________________________
The SKIPPER Speed Log Repeater allow important speed values from log
systems to be displayed anywhere on the vessel in the format the user wants.
The Compact is unique in its simple, yet exible way to display vital data in
almost all conditions, from no light to bright sunlight. In addition, it is classed to
IP56 allowing it to be mounted outside and used in any conditions. The unit is
a standard 144 mm standard format allowing it to be mounted in tight spaces
or overhead.
2 m
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Skipper Répétiteur