Parameter Size: 1 Byte
Available Settings: 0, 1.
Default Setting: 1.
6. Configure report by Current Changed
This parameter defines by how much current changed must change to be reported to
the Z‐Wave Controller or Z‐Wave Gateway, in percent. If the rate of current change ratio
is greater than this parameter, the plug will report the results, voltage, current, power
and energy, that plug measure to Z‐Wave Controller or Z‐Wave Gateway.
‘0’ – The Meter measuring values are not be reported to controller and ignores the load
current changed.
Function: Meter Reporting Setting
Parameter Number: 6.
Parameter Size: 1 Byte
Available Settings: 0 – 100 (%).
Default Setting: 5(%).
7. Remember Relay ON/OFF status
This parameter defines the relay status if remember or not. If remembered, the plug will
restore the relay status last power off when the plug supply power next time.
Function: Remember Relay Status
Parameter Number: 7.
Parameter Size: 1 Byte
Available Settings: 0 , 1
0 – Don’t Remember, the relay will keep OFF when Plug Supply Power.
1 – Remember the Relay Status.
Default Setting: 1.
8. Configure Plug Time switch Function
This parameter defines the timer function Enable/Disable. This parameter can be
configured with 0 or 1, where 0 means disable time switch function and 1 enable. The
period will be defined in parameter #9.
If this parameter is Set to 1, and when turn the plug relay on, the timer in plug start run
with time period defined in parameter #9 and the plug will turn the relay off.
Function: Time switch Configure
Parameter Number: 8.
Parameter Size: 1 Byte
Available Settings: 0, 1
0 – Time switch Disable.
1 – Time switch Enable.
Default Setting: 0
9. Configure Time switch Period
This parameter defines the period that plug time switch off. This parameter can be
configured 1 ~ 65535(in minutes). If Parameter #9 is set to ‘1’, and relay is turn‐on, the
relay will be turn‐off after delay this parameter.
Function: Time switch Configure
Parameter Number: 9.
Parameter Size: 2 Byte
Available Settings: 1 ~ 65535(minutes).
Default Setting: 150(min)
10. Button On/Off Enable
This parameter defines the button on/off function is enabled or not on the top of the
wall plug.
This parameter can be configured 0 and 1. If this parameter is set to ‘1’, users can turn
on and off the wall plug by pressing the button on the top of the wall plug. If this
parameter is set to ‘0’, the wall plug cannot be turned on and off by pressing the button.
Function: Enable Button On/Off