SIGLENT SPA1010 Series Manuel utilisateur

SPA1010
Power Amplifier
User Manual
UM60010-E01B

SPA1010 Power Amplifier User Manual
2 / 16 WWW.SI GLENT.CO M
Contents
CONTENTS ..............................................................................................................................................2
1GENERAL SAFETY SUMMARY.......................................................................................................3
1.1 SAFETY TERMS AND SYMBOLS........................................................................................................3
1.2 WORKING ENVIRONMENT ...............................................................................................................3
1.3 COOLING REQUIREMENTS ..............................................................................................................4
1.4 USE THE PROPER POWER ADAPTER ...............................................................................................5
1.5 CLEANING.....................................................................................................................................5
1.6 ABNORMAL CONDITIONS.................................................................................................................5
2SPA1010 POWER AMPLIFIER INTRODUCTION ............................................................................7
3QUICK START ..................................................................................................................................8
3.1 GENERAL INSPECTION....................................................................................................................8
3.2 THE FRONT PANEL ........................................................................................................................9
3.3 THE REAR PANEL ..........................................................................................................................9
4OPERATION ...................................................................................................................................10
5APPLICATION EXAMPLES............................................................................................................11
6TROUBLESHOOTING ....................................................................................................................12
7SPECIFICATIONS...........................................................................................................................13
8CONTACT SIGLENT.......................................................................................................................15

SPA1010 Power Amplifier User Manual
3 / 16 WWW.SI GLENT.CO M
1General Safety Summary
This chapter contains information and warnings that must be followed to keep
the instrument operating under the appropriate safety conditions. In addition to
the safety precautions specified in this section, you must also follow
recognized safety procedures.
1.1 Safety Terms and Symbols
When the following symbols or terms appear on the front or rear panel of the
instrument or in this manual, they indicate special care in terms of safety.
This symbol is used where caution is required. Refer to the
accompanying information or documents in order to protect against
personal injury or damage to the instrument.
This symbol warns of a potential risk of shock hazard.
This symbol is used to denote the measurement ground connection.
This symbol is used to denote a safety ground connection.
This symbol is used to represent alternating current, or "AC".
CAUTION
The "CAUTION" symbol indicates a potential hazard. It calls
attention to a procedure, practice or condition which may be
dangerous if not followed. Do not proceed until its conditions are fully
understood and met.
WARNING
The "WARNING" symbol indicates a potential hazard. It calls
attention to a procedure, practice or condition which, if not followed,
could possibly cause bodily injury or death. If aWARNING is
indicated, do not proceed until the safety conditions are fully
understood and met.
1.2 Working Environment
This instrument is intended for indoor use and should be operated in a clean,

SPA1010 Power Amplifier User Manual
4 / 16 WWW.SI GLENT.CO M
dry environment with an ambient temperature range of 0 °C -40 °C.
Note:Direct sunlight, radiators, and other heat sources should be taken into
account when assessing the ambient temperature.
WARNING: Do not operate the instrument in an explosive atmosphere
or wet and damp conditions.
CAUTION: Do not connect the output to a signal source or power
source.
CAUTION: The input impedance of the instrument (Zi) is 15 kΩ, and
the range of voltage is -6.5 V ~ +6.5 V (1X voltage gain) or -1.3 V ~
+1.3 V (10X voltage gain setting).
Input exceeds these ranges may cause damages to the instrument or
other hazards.
1.3 Cooling Requirements
This instrument relies on the forced air cooling with internal fans and
ventilation openings. Care must be taken to avoid restricting the airflow
around the apertures (fan holes). To ensure adequate ventilation, it is required
to leave enough gap around the sides of the instrument.
CAUTION: Do not block the ventilation holes located on both sides of
the instrument.
CAUTION: Do not allow any foreign matter to enter the instrument
through the ventilation holes, etc.

SPA1010 Power Amplifier User Manual
5 / 16 WWW.SI GLENT.CO M
1.4 Use The Proper Power Adapter
Use only the power adapter provided in the accessories. Use only the power
cord specified for this adapter and certified for the country of use.
CAUTION: Do not use any other adapters to supply power for the
instrument, or it may cause degradation or perpetual damage.
1.5 Cleaning
Clean only the exterior of the instrument, using a damp, soft cloth. Do not use
chemicals or abrasive elements. Under no circumstances allow moisture to
penetrate the instrument. To avoid electrical shock, unplug the power cord
from the AC outlet before cleaning.
WARNING: Electrical Shock Hazard!
No operator serviceable parts inside. Do not remove covers.
Refer servicing to qualified personnel
1.6 Abnormal Conditions
Only operate the instrument for the purposes specified by the manufacturer.
Do not operate the instrument if there is any visible sign of damage or has
been subjected to severe transport stresses.
If you suspect the instrument’s protection has been impaired, disconnect the
power cord and secure the instrument against any unintended operation.

SPA1010 Power Amplifier User Manual
6 / 16 WWW.SI GLENT.CO M
Proper use of the instrument depends on careful reading of all instruction and
labels.
WARNING: Any use of the instrument in a manner not specified by the
manufacturer may impair the instrument’s safety protection. This
instrument should not be directly connected to human subjects or used
for patient monitoring.

SPA1010 Power Amplifier User Manual
7 / 16 WWW.SI GLENT.CO M
2SPA1010 Power Amplifier Introduction
The SPA1010 is a power amplifier designed to source up-to 1 MHz full power
bandwidth at 90 V/us slew rate. It is ideal for increasing the power output for
any SIGLENT Function/Arbitrary Waveform Generators but can also be used
with other manufacturers’ products.
Features
10 W output power
Two gain settings (x1 or x10)
Over current protection and over temperature protection
Compact size, easy to carry and use.

SPA1010 Power Amplifier User Manual
8 / 16 WWW.SI GLENT.CO M
3Quick start
This chapter shows you how to operate the front/rear panel and steps for your
first use of the instrument.
3.1 General Inspection
1. Inspect the shipping container.
Keep the damaged shipping container or cushioning material until the
contents of the shipment have been completelychecked and the instrument
has passed both electrical and mechanical tests.
The consigner or carrier will be responsible for damages to the instrument
resulting from shipment. SIGLENT would not provide free maintenance or
replacement.
2. Inspect the instrument.
If there are instruments found damaged, defective or failure in electrical and
mechanical tests, please contact SIGLENT.
3. Check the accessories.
Please check the accessories according to the packing list. If the
accessories are incomplete or damaged, please contact your SIGLENT
sales representative.

SPA1010 Power Amplifier User Manual
9 / 16 WWW.SI GLENT.CO M
3.2 The Front Panel
Figure 1 SPA1010 Front Panel
Status Indicators
Power: On Green, indicates that the power supply is operating and the
instrument is on.
Short: On Red, indicates that the over current protection is enabled.
X10: On Green, indicates that the voltage gain select is set to X10.
3.3 The Rear Panel
Figure 2 SPA1010 Rear Panel
Output Terminal
Output Switch
Switch
Status Indicators
Gain Switch
Input Terminal
Power In
Air Vents

SPA1010 Power Amplifier User Manual
10 / 16 WWW.SIGLENT.COM
4Operation
For the details of each selection on thefront panel of SPA1010, seetablebelow:
Function
Setup
Explanation
Gain
X1, X10
Sets the gain. The input ranges of signals
are different with different gain settings.
Output
Switch
ON, OFF
Enables or disables the output.
Autres manuels pour SPA1010 Series
1
Table des matières
Autres manuels SIGLENT Amplificateur