Siedle EC 602-02 Manuel d'installation

Programming Instructions
Entry Controller
EC 602-02

2
Contents
General remarks 3
Input units 4
Programming/Operator interface 5
Circuit diagram relating to
the programming examples 6
Programming example
with 1 COM 611-... 7
Programming example
with 1 ELM 611-... 9
Programmable menu points 11
Programming overview 12
Inputs 14
Code request 14
System 15
• Language 15
• Relay function 16
• Gateway function 18
• Changing the code 20
• Disable time 20
Code 22
• Code input 22
• Relay selection 23
• Gateway selection 24
• Time control 24
Key card 25
• Card input 25
• Relay selection 26
• Gateway selection 26
• Time control 27
• Subsequent read-in 28
Key button 29
• Relay selection 29
• Gateway selection 30
• Time control 30
Time 32
Deletion 34
Information 36
Reset 39

3
General Remarks
Application
The Easikey Controller EC 602-... is
used as an evaluating unit for a
maximum of 8 code lock modules
COM 611-... and/or max. 8
Electronic-Key-reading modules
ELM 611-... and/or a
Programming
The EC 602-... / ECE 602-... is
programmed at the keypad directly
at the EC 602-...
Code
The programming menu of the
EC 602-... can be protected against
unauthorized access by means of a
code. No default code is entered in
the unit.
For code input, see page 14.
Continuous display
Display after switching on the
EC 602-...
After appr. 7 secs.
Remark:
The system is only operational if
a continuous display is visible.
Note
If no input is made for longer than
10 minutes in a programming menu,
the EC 602-... automatically switches
back to the continuous display.
maximum of 8 fingerprint modules
FPM 611-... and/or 8 display call
modules DRM 611-...
The EC 602-... comprises 2 relays
(switching outputs), the extension
unit ECE 602-... offers a further
6 relays, making available a max.
of 8 relays.
It is possible to program codes even
if there are no COM 611-... units
connected.
It is not possible to program
!the FPM 611-... via the
EC 602-...
Display
Continuous display
SSS Siedle
EC 602-02 V2.xx
EKC/EK 601-... can only be
programmed if ELM 611-... units are
connected.

4
Input Units
Address setting
COM 611-...
ELM 611-...
FPM 611-...
DRM 611-...
All COM 611-..., ELM 611-...,
FPM 611-... and DRM 611-... units
connected to the EC 602-.../
ECE 602-... must be given an
address between 1 and 8.
Under the lid at the back next to the
outlet for the ribbon cable, is the
respective BCD switch for address
setting. COM 611-... and/or
ELM 611-... and/or FPM 611-...
and/or DRM 611-... units combined
in a door station are each given the
same address. The default address 1
is always set as standard at all units.
Addresses 0 and 9 and double
address allocations (at different door
stations) lead to a system
malfunction.
LED displays at the ELM 611-...
Red LED flashing: For 3 seconds if an unauthorized
EKC 601-... or EK 601-... is presented.
Green LED flashing, red For 1 second as confirmation when
LED alight: reading in EKC 601-... or EK 601-...
Green LED flashing: For 3 seconds as confirmation of
executed switching function.
Green LED alight: Continuously when unit is operational.
Red and green LED For 10 seconds when switching on the
flashing alternately: unit.
Red and green LED In the programming mode when reading in
both alight: EKC 601-... / EK 601-...
Red LED flashing, green When all 999 EKC/EK 601-...
LED alight: have been read in.

Button functions
Scroll buttons For scrolling forward and back between
and in the programming menus, and for
selecting functions and digits.
Cursor buttons Used for scrolling to the next function or
digit input.
Programming Used to enter the programming level
button and to confirm (save) your inputs.
Cancel button Used to quit the individual programming
menus and to terminate the
programming session.
The scrolling and cursor buttons are
fitted with a repeat function.
If the buttons are held down, the
digits automatically count upwards
or the cursor changes continuously
between the individual positions.
5
Programming/Operator Interface
Explanation of Symbols and Button Functions
Access to the keypad and the
display
The lid of the housing can be
opened by pulling at the upper
edge. The display and keypad are
located under the housing lid.
OK
ESC

6
Circuit Diagram relating to the
Programming Examples

7
Programming Example
with 1 COM 611- ...
System with EC 602-... and
1 COM 611-... to actuate e.g. 1
door release via relay 1. The door
release is to remain switched on
Use the programming button to
access the main menu.
Use the scroll button to access the
Code menu.
Using the programming button
access the programming point
„Enter code“.
Use the programming button to
access the programming level.
Now enter the 1-8 digit code
number, for example 132.
Use the scroll button to select the
number „1“ in our example. Each
time the button is pressed, the
number is indexed upwards.
Use the cursor button to scroll to the
next position.
Continuous display
Press the programming button
Display
Press the scroll button
Display
Press the programming button
Display
Press the programming button
Display
Press the scroll button several times
until you reach the number „1“.
Display
Press the cursor button
Display
SSS Siedle
EC 602-02 V2.xx
OK
OK
OK
for 3 seconds.
Switching contact at relay 1:
Terminals W0 and W2 (n.o.
contacts)
SYSTEM
= Next OK = Prog
CODE
= Next OK = Prog
Enter code
= Next OK = Prog
= New OK = Save
Code 01 _
= New OK = Save
Code 01 1
= New OK = Save
Code 01 1

8
For the remaining positions of the
code number, repeat the last two
steps.
Once you have entered all the
numbers, press the programming
button to save your entry.
Use the scroll button to assign code
01 to relay 1.
Using the programming button, save
your entry.
Using the cancel button, return to
the Code menu.
Using the cancel button, quit the
programming level.
The programming sequence is
now completed.
Display
Press the programming button
Display
Press the scroll button
Display
Press the programming button
Display
Press the cancel button
Display
Press the cancel button
Continuous display
Relay 12
Code 01 _
Relay 12
Code 01 L
Disable with Inp.1
Code 01 NO
SSS Siedle
EC 602-02 V2.xx
OK
OK
ESC
ESC
CODE
= Next OK = Prog
= New OK = Save
Code 01 132_

Switching contact of relay 1:
Terminals W0 and W2
(n.o. contacts)
• Please number through the
EKC 601-... and/or EK 601-... you
wish to read in starting with no.
001.
9
System with EC 602-... and
1 ELM 611-... to actuate for example
1 door release via relay 1. The door
release is to stay switched on for 3
secs.
Use the programming button to
access the main menu.
Press the scroll button to enter the
Key card menu.
Use the programming button to
access the programming point
„Card input“.
Use the programming button to
enter the programming level.
Holding the EKC/EK 601-... you
wish to read in, approach the
reading module ELM 611-... at
which both LEDs are alight. Hold the
EKC/EK 601-... with the number 001
in front of the ELM 611-...
Once the card has been read in, the
green LED 1 flashes for one second
as a confirmation.
Read in further EKC/EK 601-... units
in ascending numerical sequence in
the same way.
After reading in the 999th EKC/
EK 601-..., the red LED flashes while
the green LED is continuously alight.
Continuous display
Press the programming button
Display
Press the scroll button twice
Display
Press the programming button
Display
Press the programming button
Display
Programming Example
with 1 ELM 611- ...
OK
OK
OK
It is not possible to read in any
further EKC/EK 601-... units.
If, for example, you have read in 10
EKC/EK 601-.. units you will see the
following display at the EC 602-...
(illustrated on page 10):
SSS Siedle
EC 602-02 V2.xx
SYSTEM
= Next OK = Prog
Key card
= Next OK = Prog
Card input
ESC = Cancel OK = Prog
= New OK = Save
Card 001 NEW

10
Using the programming button,
confirm read-in of the EKC/
EK 601-...
Using the scroll button, assign the
card 001 to relay 1.
Use the programming button to
store your input.
Using the programming button,
index to the next number.
For additional EKC/EK 601-... units ,
repeat the previously described
steps.
Once all the EKC/EK 601-... units
have been programmed, switch back
to the Key Card menu using the
cancel button.
Use the cancel button to quit the
programming level.
The programming sequence is
now completed.
Display
Press the programming button
Display
Press the scroll button
Display
Press the programming button
Display
Press the programming button
Display
Press the cancel button
Display
Press the cancel button
Continuous display
Relay 12
Card001 _
Relay 12
Card001 L
Disable with input 1
Card 001 NO
Relay 12
Card002 _
SSS Siedle
EC 602-02 V2.xx
OK
OK
OK
ESC
ESC
= New OK = Save
Card 011 NEW
Key card
= Next OK = Prog
Table des matières