Sibata DAS-100 Manuel utilisateur

OPERATIONMANUAL
CODE 090150-70
Read this operation manual before using the product.
Thank you for purchasing this product.
•This operation manual describes precautions that are important for preventing accidents
as well as procedures used to handle the product.
•To ensure safety, read this operation manual thoroughly before use and use the product
correctly.
•After reading this operation manual, keep it handy for future reference.
Semi-Active Sampler
DAS-100


- 3 -
Table of Contents
Before Use ............................................................................................ 4
Safety Precautions ............................................................................... 6
1Product Overview............................................................................ 9
2Features.......................................................................................... 9
3Type of Battery Used and Sampler Operation .............................. 10
4Names of Parts ............................................................................. 10
5User Instructions ........................................................................... 12
5-1 Preparation............................................................................................ 12
5-2 Sampling ............................................................................................... 12
5-3 After Sampling....................................................................................... 15
5-4 Storage.................................................................................................. 15
6Troubleshooting ............................................................................ 16
7Specifications................................................................................ 17
8Warranty and Repairs ................................................................... 18
9Product Disposal........................................................................... 18
10 Inquiries ........................................................................................ 18
Problem Report Form ......................................................................... 19

- 4 -
Before Use
•Read this operation manual thoroughly before use, and
use the product correctly.
•Keep this operation manual handy for future reference.
•Be sure to familiarize yourself with, and observe, the
safety precautions given in this operation manual.
•Observe usage procedures that are suitable for the
product and that are specified in this operation manual.
•This product is not designed to be explosion-proof. To
prevent explosion accidents, do not use it in
dangerous locations.
Be sure to observe the above instructions.
Not doing so may result in an accident or injury.
About This Operation Manual
•Information in this operation manual is subject to change without notice in the interest
of product improvement.
•Every effort has been made to ensure that the information in this operation manual is
correct. If you discover any errors or omissions, however, please contact your Sibata
representative.
•The copyright of this operation manual belongs to Sibata Scientific Technology Ltd.
This operation manual, or any part thereof, may not be reproduced, reprinted, or
altered in any form without prior written permission from Sibata Scientific Technology
Ltd.

- 5 -
Checking Packaging Contents
(Please verify contents before using the product.)
DAS-100 Semi-Active Sampler···················································· 1
Tube for installing activated carbon passive gas tube ······················· 1
(for installing 080150-066 tube)
Positioning stopper for activated carbon passive gas tube ················· 1
(for installing 080150-066 tube)
Plug A for installing DNPH passive gas tube ··································· 1
(for installing 080150-075 tube)
Note: Threaded hole included on one side.
Plug B for installing DNPH passive gas tube··································· 1
(for installing 080150-075 tube)
Note: 5 mm diameter hole included on one side.
Operation manual (this manual)··················································· 1
Note: The battery is not included. Please obtain it separately.

- 6 -
Safety Precautions
The precautionary information in this operation manual is for ensuring that the product
is used safely and for preventing injury to you and other people and damage to
equipment. It is all important for ensuring safety, so be sure to read it thoroughly before
using the product and observe it during use.
Graphical Symbols
This operation manual uses various graphical symbols to indicate warnings and
instructions. These consist of two categories, WARNING and CAUTION, which are
indicated based on the severity of consequences if the corresponding warning or
instruction is ignored and the product is operated improperly. Always observe these
warnings and instructions, as they include important information about safety.
Labels Indicating Degrees of Damage or Injury
Indicates a potentially hazardous situation which,
if not avoided, will result in serious injury or death.
Indicates a potentially hazardous situation which,
if not avoided, may result in injury or equipment
damage.

- 7 -
•Do not apply chemicals to the product. Doing so could cause a malfunction or fire.
•This product is not designed to be explosion-proof. Do not operate the product near
highly flammable or combustible items. Doing so could cause explosion or fire.
•Keep the product away from open flames. Do not burn the product in a fire. Doing so
could cause explosion or fire.
•This product is not designed to be water-proof. Do not get water or other liquids on the
product. Doing so could cause a malfunction or fire.
•Do not subject the product to strong impacts or drops. Doing so could cause a
malfunction or accident.
•Never attempt to disassemble or modify the product. Doing so could cause a
malfunction or accident.
•If a problem occurs during operation, immediately stop operating the product, and
remove the cause. If it is determined that the product caused the problem, remove the
battery and then contact your Sibata representative or the store where you purchased
the product. Never operate the product if it is not functioning normally. Also, never allow
anyone other than a qualified service engineer to disassemble or modify the product.
Doing so could cause a malfunction or accident.
•Use a new AA alkaline battery. Using any other battery not only could prevent the
product from functioning properly, it could also cause an accident, malfunction, electric
shock, or fire.
•Do not touch the product with wet hands. Doing so could cause a malfunction.

- 8 -
•The product is a sampling device that uses a passive sampler. Do not use it for any
purpose not indicated in this manual. Doing so could cause a malfunction.
•Do not wash the product directly in water. Doing so could result in malfunction.
•Do not place anything on top of the product. Doing so could cause the product falling
down, deformation, malfunction or accident.
•Remove the battery before cleaning or inspecting the product. Not doing so could cause
an injury or malfunction.
•Remove the battery when the product is not in use. Not doing so could cause a
malfunction.
•If not using the product for an extended period, remove the battery and store it at normal
room temperature in a dry location away from direct sunlight. Not doing so could cause
a malfunction or other problems.
•Never attempt to connect to the battery case with wire or other metal objects, or any
other method not specified in this manual. Doing so could cause a malfunction.
•Do not permit water, other liquids, or non-atmospheric gases to enter the product. Also,
do not permit salt air or other corrosive gases or chemicals to enter the product, either.
Doing so could cause a malfunction or fire.
•Do not insert screws or other foreign objects into product gaps. Doing so could cause a
malfunction. If a foreign object accidentally enters the product, immediately stop the
measurement, remove the battery, and contact your Sibata representative or the store
where you purchased the product.
•The normal operating temperature range of this product is 5 to 35 °C, with humidity
between 20 and 75 % RH (and no condensation). Operating the product outside these
temperature and humidity ranges could reduce performance, shorten the service life, or
cause a malfunction.
•Keep the product away from sources of noise. Also, do not place it in areas with strong
magnetic fields, high dust levels, or high humidity. Doing so could cause product
damage or other problems.
•Be sure to operate the product using a new AA alkaline battery. The fan and LED
functions may not be coordinated properly if the battery is depleted.
•Hold the battery case when removing the battery cap to remove or install the battery.
Removing the battery cap while holding other areas of the main unit could cause the
removal of parts unnecessary for battery replacement.

- 9 -
1 Product Overview
The DAS-100 semi-active sampler is a peripheral device that assists sampling with
passive samplers. The product generates a constant air flow near the passive sampler
to help prevent any wind speed fluctuations from affecting the sampling rate. One new
AA alkaline battery enables over 30 hours of sampling.
With quiet operation during sampling and a compact easily portable design, the DAS-
100 enables a wide variety of on-site measurement applications, such as measuring
personal exposure levels.
2 Features
•Can install a passive sampler to minimize wind speed effects during sampling.
•Can install the following Sibata passive samplers.
080150-066: Passive gas tube (for organic solvents)
080150-075: DNPH passive gas tube
•Using an extension enables two types of passive samplers to be used simultaneously
for sampling (example: passive gas tube plus DNPH passive gas tube).
•Because the sampler can be operated for over 30 hours using one new AA alkaline
battery, it can be used for personal exposure sampling 24 hours a day.
•The included hanger rings can be used to wear the sampler around the neck, such as
by hanging it from a lanyard strap. (Be careful not to get the strap caught on objects.)
•The threaded mounting hole on the bottom allows the sampler to be mounted to any
commercial tripod for sampling.

- 10 -
3 Type of Battery Used and Sampler
Operation
To ensure the product functions properly, use a new AA alkaline battery each time the
product is used. The fan and LED functions may not be properly coordinated if the
battery is depleted.
The product's LED indicator is for confirming the product function when a new alkaline
battery is installed. It may not be possible to properly confirm sampler functionality if a
partially used battery is installed or after the sampler has been operated for 24 hours.
Confirm both that the fan rotates and that the LED illuminates when the product is
operating.
Hold the battery case when removing the battery cap to remove or install the battery.
Removing the battery cap while holding areas other than the battery case could cause
the removal of parts unnecessary for battery replacement.
4 Names of Parts
Exterior of Semi-Active Sampler
Sample intake port cap Holder
Extension
Fan motor
(and exhaust port) Battery cap
Tripod mount
Battery case
LED indicator
Hanger rings
Table des matières
Autres manuels Sibata Échantillonneur
Manuels Échantillonneur populaires d'autres marques

Akai
Akai MPCX Manuel utilisateur

KAM
KAM Simple Precision IAS Manuel utilisateur

YZ Systems
YZ Systems DynaPak DP-2010FU Manuel de la liste des pièces

YZ Systems
YZ Systems DynaPak 2010N Series Manuel utilisateur

YZ Systems
YZ Systems DynaPak DP-2010UX Manuel de la liste des pièces

Novation
Novation Circuit Rhythm Manuel utilisateur

















