SGM GB
Fogger 1000 - Fogger 1500
5
Adapte and Nut must be tightly connected
Assemble 2 washers in both inner sides o the
mounting bracket with ixation screws on the
outer sides
Note: A luid level sensor is installed on the unit. The machine will stop to og i the luid is lower than
usable level.
I you experience low output, pump noise or no output at all, unplug immediately. Check luid level, the
external use, remote control connection and power rom the wall. I all o the above appears to be O.K.,
plug the unit again. I og does not come out a ter holding the remote button down or 30 seconds, check
the hose attached to the tank to make sure there is luid going through the hose. I you are unable to
determine the cause o the problem, do not simply continue pushing the remote button, as this may
damage the unit. Return the machine to your SGM dealer.
6TECHNICAL SPECIFICATIONS
Model FOGGER 1500 FOGGER 1000
Power Supply AC100V - AC120V - AC230V - AC240V, 50Hz-60Hz
Power Co sumptio 1,500 W 1,000 W
Output Volume 600 m³/min. 300 m³/min.
Ta k Capacity 6 liters 2.4 liters
Fluid Co sumptio 8,5 min./ liter 13 min./ liter
Weight 15 kg 9.8 kg
Dime sio s (LxWxH) 552 x 230 x 155 mm 370 x 295 x 135 mm
Remote I cluded Z-10 Z-10
Optio al Remote Z-40, Z-50 Z-40, Z-50
Warm-up Time 8.5 min. 10 min.
7REMOTE CONTROL OPERATION
Z-10: 10 meter wired remote controller with 6,3 mm jack plug o SGM og machine models Fogger
1000 and Fogger 1500. The red lamp indicates that the unit is receiving power. When the og
machine has reached operating temperature the green light on this remote control will light up,
indicating that the operator may begin og emission by pressing the red button. The green light
lashes during og machine warm-up and re-heating cycles (approx. 1-2 minutes), and stays ON
when the machine becomes operational. The Z-10 eatures the “toggle switch’’ unction: press once
or continuous “on”, press again to release continuous “on” unction
Z-40: 10 meter wired remote controller with 6,3 mm jack plug or SGM og machine models Fogger
1000 and Fogger 1500. Its two knobs allow the operator to customize og machine unctions by
adjusting output duration and interval. Press the yellow TIMER-button to activate the timer unction.
Adjust the interval between each og emission (within the range o 1 second to 250 seconds) by
means o the INTERVAL control knob. Adjust the duration o each og emission (within the range o 1
to 15 seconds) by means o the DURATION control knob. When pressed, the green FOG button