sewerin COMBIPHON CG 150 Manuel utilisateur

12.12.2023 a – 108797 – en
COMBIPHON®
CG 150 generator
Striker and stopper
Operating instructions

CG 150 generator
Fig. 1: CG 150 generator with an opened case
Fig. 2: Control panel
Control panel
Charging socket
Port for accessories
Display
ON/OFF key
Frequency keys
Pulse button
Arrow keys
●Up key
●Down key

CG 150 generator
Hz
Fig. 3: Display (here: during energising with striker)
Frequency
Striker
Signal strength
Charge
Signal behaviour

Illustration of warnings in this document
NOTICE!
Risk of damage to property.

Contents│ I
1 Introduction .............................................................................1
1.1 Information about this document...............................................1
1.2 Purpose.....................................................................................1
1.3 Intended use .............................................................................2
1.4 Safety information .....................................................................2
2 Product description ................................................................4
2.1 General .....................................................................................4
2.2 CG 150 generator .....................................................................4
2.2.1 Ports.......................................................................................4
2.2.2 Power supply..........................................................................4
2.2.3 Remote control.......................................................................5
2.3 Optional accessories.................................................................5
2.3.1 Striker.....................................................................................5
2.3.2 Stopper...................................................................................5
2.4 Settings for energising ..............................................................5
2.4.1 Frequencies ...........................................................................6
2.4.2 Signal strength .......................................................................6
2.4.3 Signal behaviour ....................................................................6
3 Energising pipes .....................................................................8
3.1 Switchingthegeneratoronando............................................8
3.2 Selecting a frequency................................................................8
3.3 Setting the signal strength.........................................................8
3.3.1 Signal strength of the striker ..................................................8
3.3.2 Signal strength of the stopper ................................................9
3.4 Selecting the signal behaviour of the striker .............................9
3.5 Energising using a striker..........................................................9
3.6 Energising using a stopper......................................................10
3.7 Using the remote control .........................................................12
3.7.1 Usingtheremotecontrolforthersttime ............................12
3.7.2 Pause function .....................................................................12
3.7.3 Setting the signal strength (striker only)...............................13
4 Maintenance ..........................................................................14
4.1 Charging the rechargeable battery..........................................14
4.2 Care ........................................................................................15
4.2.1 Cleaning the generator and striker.......................................15
4.2.2 Cleaning the stopper ............................................................15

II │Contents
4.2.3 Water in the case .................................................................17
4.2.4 Storage.................................................................................17
4.3 Servicing .................................................................................17
4.4 Troubleshooting.......................................................................17
4.4.1 Generator .............................................................................17
4.4.2 Striker...................................................................................18
4.4.3 Stopper.................................................................................18
5 Appendix................................................................................20
5.1 Technical data .........................................................................20
5.2 Symbols on the display ...........................................................21
5.3 Accessories.............................................................................22
5.4 Declaration of conformity ........................................................22
5.5 Advice on disposal ..................................................................22
6 Index.......................................................................................23

1 Introduction│ 1
1 Introduction
1.1 Information about this document
This document is a component part of the product.
●Read the document before putting the product into operation.
●Keep the document within easy reach.
●Pass this document on to any subsequent owners.
● Unlessotherwisespecied,theinformationinthisdocument
refers to the product as delivered (factory settings) and applies
to all product variants.
Translations
Translations are produced to the best of our knowledge. The
original German version is authoritative.
Right of reproduction
Nopartofthisdocumentmaybeedited,duplicatedorcirculated
in any form without the express consent of Hermann Sewerin
GmbH.
Registered trademarks
Registered trademarks are generally not indicated in this
document.
1.2 Purpose
The portable CG 150 generator is part of the COMBIPHON
system.
The generator is suitable for the acoustic energising of pipes laid
outdoors.

2 │1Introduction
1.3 Intended use
The product is suitable for the following uses:
●Professional
●Industrial
●Commercial
Theproductmustonlybeusedfortheapplicationsspeciedin
section 1.2.
The product may only be used by the following persons1:
●Technicians
●Trained persons
1.4 Safety information
This product was manufactured in accordance with all binding
legal and safety regulations.
The product is safe to operate when used in accordance with the
instructionsprovided.However,whenhandlingtheproduct,there
mayberiskstopersonsandproperty.Forthisreason,observe
the following safety information without fail.
●
Observe all the applicable safety standards and accident
prevention regulations.
●Use the product only as intended.
●
Donotmakeany changes or modications totheproduct
unless these have been expressly approved by Hermann
Sewerin GmbH.
●Only use accessories approved by Hermann Sewerin GmbH.
●
Always observe the permitted operating and storage
temperatures.
● Handletheproductcarefullyandsafely,bothduringtransport
and when working. For example:
−Do not drop the generator.
−Always set the generator down carefully.
−Secure the generator against slipping when transporting it
in the vehicle.
1asdenedinEN62368-1

1 Introduction│ 3
● Alwaysadequatelycordonotheworkarea.
●
When you are wearing headphones, you are not fully
awareofambientnoise.Beespeciallyvigilant,especiallyin
environmentswithanincreasedriskofaccident(e.g.trac).
●Do not use the product if it is damaged or faulty.
● Protecttheportsandsocketsagainstdirt,andelectricalports
in particular against moisture.
●Proceed with extreme caution in the vicinity of electrical lines.

4 │2Productdescription
2 Product description
2.1 General
The CG 150 generator is used to energise pipes for acoustic
location. The generator is therefore also often referred to as the
transmitter.
Pipes that are not electrically conductive can be made to vibrate
by the generator with a connected striker or stopper. The acoustic
signals generated in this way can be located acoustically using a
suitable system (e.g. AQUAPHON system).
A remote control is included in the generator delivery
Energising requires a striker or a stopper. A striker and stopper
can be purchased as accessories.
2.2 CG 150 generator
The generator is permanently installed in a case. An overview
with the names of the generator parts can be found on the front
cover(g.1andg.2).
2.2.1 Ports
The generator has the following ports:
●Charging socket
for connecting AC/DC adapter L or vehicle cable L
●Port for accessories
for connecting a striker or stopper
The CG 150 generator recognises the intended use based on
the connected accessory.
2.2.2 Power supply
Thegeneratorispoweredbyaspecial,permanentlyinstalled
Pb rechargeable battery. Information about charging the
rechargeable battery can be found in section 4.1.
Table des matières
Autres manuels sewerin Générateur portable