9
OPERATION METHOD
Cooling Mode
•When the A/C enters cooling mode automatically or cooling mode is
selected after power ON, the cooling indicator lamp lights up.
•Press Up/Down key to adjust setting temperature (16°C~30°C)(60°F~86°F).
•Press Speed key to choose High/Mid/Low speed.
Fan Mode
•When pressing mode key or choosing Fan mode by pressing the remote
controller, the wind indicator lamp lights up.
•Press Speed key to choose High/Mid/Low speed.
•Temperature can’t be set.
Dehumidication Mode
•When pressing mode key or choosing
dehumidication mode by pressing the
remote controller, the dehumidication
indicator lamp lights up.
•Remove the dehumidication water wedge,
insert water manifold, place the other end
of the water manifold into the water vessel
or drainage passage, as shown in the right
gure.
•After entering the dehumidication mode,
if room tempearture≥17°C (62°F), the compressor is ON. Then control as
follows: when room temperature ≤15°C (59°F), the compressor is OFF;
when temperature increases to room temperature≥17°C (62°F), the
compressor will start again (in order to protect the compressor, it will be
restarted 3min. later).
•In dehumidication mode, the fan is defaulted to run at low speed, and
wind speed can’t be adjusted.
•Temperature can’t be set.
Note : When use dehumidify function, should remove
exit pipe components, otherwise, it will cause worse dehumidify
performance, and appear “FL” water full alarm
www.SereneLifeHome.com