4-4-24,NISHINAKAJIMA,YODOGAWA-KU,
OSAKA 532-0011 JAPAN
Tel.06(6304)8858 Fax.06(6302)0700
URL http://www.sentec.co.jp/
OUTPUT
(%)
φB/φA
100
80
60
40
20
1 2
Shield
Non-shield
φBφA
SENSOR
φB/φA
100
80
60
40
20
12 3 4 5 6 7
φB
φA
SENSOR
OUTPUT
(%)
MEASUREMENT(mm)
2
1
1(F.S) 2
Al
Cu
Fe
sus304
OUTPUT
Zero adjustment and Span
adjustment are the graph
set up similarly to an
iron state.
Zero-ADJ Range
Measure(mm)
Standard
Span-ADJ Range
10
0
-3dB
Frequency(kHz)
52
(2)In case a subject is a pillar
A specification value will be satisfield,
if the diameter of the piller of a subject
is by the thing which has 5 or more times
of the diameter of a sensor head.
(1)For the area of subject
A specification value will be satisfied,
if a subject is a thing which has more
than the diameter of the following graph
when a subject is used as a disk.
(4)Response For Frequency
CONTROLLER-TYPE Zero-ADJ
Range(V)
Span-ADJ
Range
LS-700-08
LS-700-1
LS-700-2
LS-700-4A
LS-700-4B
LS-700-10
-0.4~+0.4
-0.4~+0.4
-0.8~+0.4
-2.0~+0.5
-1.5~+0.8
-4.0~+1.0
0.8~1.2
times
(5)ZERO-Adjustment・Span-Adjustment Range
S y m p t o m C a u s e Countermeasure
●Power indicator does not
light after power supply
is turned on.
●Output voltage does not
reach volume described
in specifications.
●ZERO-adjust and/or SPAN-
adjust not possible.
●Power line is unplugged, or power supply
terminal plug is defective.
●Sensor cord is of inappropriate length.
●Sensor wire is laid too close to other wires. ●Lay sensor wire separately from other wires.
●Controller is not compatible with sensor
other than that specified.
Use appropriate sensor.
●Equipment is designed to sense iron.
Use only for iron.
●Plug in power line property, following
instruction display.
●Replace with cord of specified length.
●Object to be sensed is material other than iron.
●Volume of subject to be sensed is less than the
standard.
●Sensor is different from that specified.
●See reference data.
●The guarantee of the product is the one to mean the
guarantee of this machine unit.
●We will make the term of a guarantee of a product
into after-shipment one year.
●When failure arises by a manufacturer's responsibi-
lity during the above-mentioned term of a guarantee,
repair of the failure portion of a product or compo-
nent replacement is performed.
However, when it corresponds to below, We will carry
out the outside of the scope of a guarantee.
①When based on unsuitable condition, environment,
handing, and use of those other than the contents
checked by the specification value of a product,
the specifications exchaged separetely, etc.
②When the cause of failure is based on reasons other
than supplies.
③By remodeling or repairing the delivery goods that
depend besides our company.
④When based on the reason which was not able to be
foreseen with the technical level at the time of
the shipment.
⑤In addition, when it is not in the responsibility
by the side of a manufacturer with a natural disas-
ter, disaster, etc.
●We can do neither conformity in the particular appli-
cation of this machine, nor compensation of guarantee
loss of the secondary value generated with a product.
Moreover, they are not a design and the manufactured
product for the purpose of the use as which very high
reliability and safety are required, and the uses
(atomic power, aerospace, infrastructure, medical equ-
ipment, etc.) concerning a human life.
About the use under such a use and environment, we
will carry out the outside of the scope of a guaran-
tee.
LS-700-5 -2.4~+1.0
※Zero-ADJ Range:When 0-ADJ is used.
The following symptoms are often mistaken for product failure.
Check the following before bringing equipment in for repair.
LS-700LS-700LS-700LS-700
①LS-700 multiple connection (power supply package supply)
Four-set simultaneous connection is possible including what wired
the power supply.
The above-mentioned number is the number it will be whose power
supply voltage at DC12V.
Wiring of a power supply is possible by every controller.
POWER
②DLC-500 (digital linear converter) connection
It sees from the front and connects DLC-500 to the left-hand side
of LS-700.
It shall be one set which was combined with DLC-500, and two-set
simultaneous connection is possible.
The above-mentioned number of sets is the number of sets at power-
supply-voltage DC12V.
The input of DLC-500 turns into an output of LS-700.
Wiring of a power supply is connected to LS-700.
Since there is possibility of the power supply line damage by fire
on a substrate when it is connected with DLC-500, please be sure
to connect with LS-700.
LS-700
DLC-
500
POWER
③DLC-500 and CH-500 (comparator module) connection
It sees from the front, and DLC-500 is connected to the left-hand
side of LS-700, and also CH-500 is connected to left-hand side.
The combination of three sets shall be one set and two-set simul-
taneous connection is possible.
The above-mentioned number of sets is the number of sets at power-
supply-voltage DC12V.
The input of DLC-500 turns into an output of LS-700.
Wiring of a power supply is connected to LS-700.
Since the power supply line on a substrate may be damaged by fire
when it is connected with other controllers, please be sure to
connect with LS-700.
LS-700
DLC-
500
POWER
CH-
500
LS-700
DLC-
500
CH-
500
④VI-300 (signal converter) connection
It sees from the front and connects VI-300 to the left-hand side
of LS-700.
It shall be one set which was combined with VI-300, and three-set
simultaneous connection is possible.
The above-mentioned number of sets is the number of sets at power-
supply-voltage DC12V.
The input of VI-300 turns into an output of LS-700.
Wiring of a power supply is connected to LS-700.
Since there is possibility of the power supply line damage by fire
on a substrate when it is connected with VI-300, please be sure to
connect with LS-700.
⑤VI-500 (isolator) connection
It sees from the front and connects VI-500 to the left-hand side
of LS-700.
It shall be one set which was combined with VI-500, and three-set
simultaneous connection is possible.
The above-mentioned number of sets is the number of sets at power-
supply-voltage DC12 V:00.
The input of VI-500 turns into an output of LS-700.
Wiring of a power supply is connected to LS-700.
Since there is possibility of the power supply line damage by fire
on a substrate when it is connected with VI-500, please be sure to
connect with LS-700.
LS-700
POWER
LS-700LS-700
VI-
300
LS-700
POWER
VI-
500
LS-700
VI-
500
LS-700
VI-
500
VI-
300
VI-
300
An exclusive DIN rail bus connector (option) is used, and power supply package supply to two or more LS-700 and connection
of our option products can be made without wiring.
However, since there are notes when connecting, please refer to the following for each connection.
LS-700
DLC-
500
●Please do not make reconstruction and decomposition absolute.
●Be careful for there to be no faulty wiring in accordance with the wiring method
written in the instruction manual.
A product may be damaged with faulty wiring.
The breakage and failure by faulty wiring become the outside of the object of a
guarantee.
●In case you perform connection, since there is a possibility of receiving an ele-
ctric shock, please work turning off the power.
●Please do not add a big vibration and a shock to a product, or do not make it to
topple a product.
Moreover, please don't place a thing in piles on a product.
It may change and damage.
●When you check that it is a product of an order at the time of unpacking of pack-
ing and there are accessories, please be careful enough not to throw away.
●When there are accesories etc., please keep it not to be intermingled.
●When you carry a product, please give treatment carefully.
●Please do not use and keep it under existence of corrosive gas.
●Keep in mind that water will infiltrate into the inside of a product and it will
become the cause of breakage if water takes at the time of use and storage.
●When you incorporate and ship a product to apparatus, please protect a product in
consideration of the vibration at the time of transportation, or a shock using
shock absorbing material etc.
●Indicated data values are measured value under the test atmosphere of our speci-
fication, and may differ from the data value of a statement in an instruction ma-
nual according to an operating condition and other terms and conditions.
●Please use a suitable tool about attachment of a product and perform attachment
which applied to the attachment method correspondingly after attention.
●Please do not use it exceeding the range of the specification.
●Please carry out warming up 20 minutes or more from a power supply injection.
●Nothing should connect with the terminal which is not used.
●Please do not set it up near the device equipment(inverter, high-frequency gene-
rating equipment, and motor, etc.)that generates big surge.
●Please separate wiring from a high-tension wire or a power line as much as possi-
ble.
It becomes the cause of malfunction or failure by a noise.
●When the influence of thunder or serge can be considered, please install protec-
tion circuits, such as a surge arrester and a surge killer.
●When you connect loads, such as a relay lamp, please install a protection circuit.
●Please avoid use in the place where a rapid temperature change is caused and the
place where the vibration is intense.
●When it installs in a moist place, a product maybe damaged by dew condensation.
Please keep dew condensation from occurring in a moist place.
If cautions are neglected, a dangerous situation which is
connected with a serious disaster is shown.
If cautions are neglected, a dangerous situation which is
connected with damage on a product is shown.
(3)The characteristic over
metal other than iron
★A specification change may be made without a
preliminary announcement for the better imp-
rovement of a product.
Please give me consent and an understanding.