4/5
Note : All parameters or functions listed in the following tables are only accessible if the sensor is in adjustment session.
The red LED is then slowly flashing.
During an adjustment session each parameter may be checked or changed at any time in the following way :
PARAMETERS OPERATIONS
CHECK VALUES
Press the key corresponding to the parameter to be checked and then press the CHECK VALUES key
Count the number of times the LED flashes, which corresponds to the value of the checked parameter. No LED flash corresponds to the
value 0. Repeat this operation to check the value of the other parameters if required.
Example : SENSITIVITY key– 4 flashes of the LED: the sensitivity is set to the value 4.
CHECK VALUES :
PLUS / MINUS
Press the key corresponding to the parameter to be modified (SENSITIVITY or HOLD TIME) and then press the PLUS key (2) or MINUS
key (4) to increase/reduce the value by 1 unit.
PLUS / MINUS : or
Note about LED signal : The LED flashes quickly waiting for the value. Once this has been entered, it flashes slowly again.
PARAMETERS OPERATIONS Definitions - Advices
SENSITIVITY
Press the SENSITIVITY key (20). Use the NUMBER keys 1-4 to enter the
required sensitivity (motion and safety)
SENSITIVITY:
HOLDTIME
Press the HOLD TIME key (6). Use the NUMBER keys 0-9 to enter the
required hold time (0.5s to 9 s)
HOLD TIME:
The hold time allows extended output activation time after
detection has stopped. It is recommended to use this
parameter instead of the operator’s with the same function
(interferences with the sensor)
DETECTION
FIELD
Press the DETECTION FIELD key (11). Use the NUMBER keys 1-9 to
select the desired detection field according to the table on the next page.
DETECTION FIELD:
The detection pattern is made of 15 independent spots
organized in 3 ranges of 5 spots parallel to the door.
Each spot can be individually switched “on” or “off”, set to
detect either motion or presence. See next page
“detection fields”
PULSE
FREQUENCY
Press the PULSE FREQUENCY key (13). Use the NUMBER keys 1-3 to
select the desired frequency:
1 : Low
2 : Medium
3 : High
PULSE FREQUENCY:
The pulse frequency is used to avoid interferences
between sensors if their respective sensing fields are
overlapping. In that case choose different frequencies for
the sensors.
OUTPUT
CONFIGURATION
Press the OUTPUT CONFIGURATION key (17). Use the NUMBER keys 1-
2to select the required output configuration :
Active
Passive
Detection
No Detection
DOOR CONTROL
Press the DOOR CONTROL key (14). Use the NUMBER keys 1-3 to select
the required door operating mode:
1 : door automatic mode
2 : door permanently open
3 : door permanently closed
DOOR CONTROL:
In “door permanently open” mode, the sensor is
continuously detecting. The red LED is continuously ON.
In “door permanently closed” mode, the sensor is in
standby. It detects nothing anymore and the LED is
continuously OFF.
MAXIMUM
DURATION OF
PRESENCE
DETECTION
Press the MAXIMUM DURATION OF PRESENCE DETECTION key (18).
Use the NUMBER keys 0-9 to select the required duration:
0 : 20 seconds 5 : 7 minutes
1 : 1 minute 6 : 10 minutes
2 : 2 minutes 7 : 15 minutes
3 : 3 minutes 8 : 20 minutes
4 : 5 minutes 9 : 25 minutes
MAXIMUM DURATION:
The sensor will integrate the new environment and return
to no-detection state if detection has exceeded the
selected time.
SETUP
0
Press the SETUP key (19) followed by the NUMBER key 0to launch a
setup of the sensor.
SETUP: