General Specifications
Sensitivity: 0.1 PPM / meter CH4 at 25 MPH
Measurement Range: 1.0 to 1000 PPM / meter
Display Ranges: Automatic
System test: Automatic during turn on
Response Check: Operator initiated; pass/fail determined by preset software limits
Calibration Adjustment: Field performed with calibration cell and on-board operator selection
via PC.
Data connection: Bluetooth
Operator Interface and Display: Backlit 7” touchscreen weatherproof notebook.
Alarms: Audible with adjustable set point
Error indications: Low Light Detection failure, Communication failure, Zero Fail, Test Fail, Cal Fail
System Power: 60 watts @ 12 VDC
System Voltage: 10-16 VDC
Mechanical Mounting: bracket mount
Installation Time: <2 hours (typical)
External Housing Rating: IP 54
Display Housing Rating: Waterproof tablet style PC
External Sub-System Materials: Aluminum and plastic
Operating Temperature Range: -22 o F to 122 o F
Operating Humidity Range: 5 to 100% RH
Warnings
Clean the lenses prior to each days use for best results.
Use extreme caution when monitoring the computer when driving. Any adjustments should be
made only when the vehicle is safely stopped away from traffic.
When not in use refer to transport position recommendation to prevent potential damage.
5