CONNECTION-WIRE DIAGRAM
Fig 4
Fig 3
Note: When testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor could not work!
CALIBRATION
1) Time setting
The light can be set to stay ON anywhere between approximately 10 seconds (turn fully
anticlockwise) and a maximum of 12 minutes (turn fully clockwise). In case any movement
is detected before the time elapses, it will automatically reset the timer. To adjust the
detection zone and perform the walk test, it is advisable to select the shortest time.
2) Light control setting
The chosen light response threshold is adjustable from approximately <3-2000 LUX.
To select the dusk-to-dawn operation at about 2 LUX, turn it fully anti-clockwise
and turn it fully clockwise to select continuous daylight operation. The knob must be
turned fully clockwise when adjusting the detection zone and performing the walk
test in daylight, then adjust the setting as per the site requirement.
Turn the LUX knob clockwise to the maximum (sun),
and then turn the TIME knob anti-clockwise to
the minimum (10s).
After the power switches on, the sensor and its connected
lamp will have no signal at the beginning. After a warmup
of 30 seconds, the sensor can start working, and the lamp
will turn on if the sensor receives the induction signal. If there is no induction signal,
the load should stop working within 10sec ± 3sec, and the lamp would turn off.
Turn the LUX knob anti-clockwise on the minimum(3). The sensor will work if the
ambient light is less than 3 LUX (darkness). Under no induction signal condition, the
sensor should stop working within 10sec ± 3sec
TEST
APPLICATION
Daylight Function
The daylight threshold is set to or 2000 disable
The light switches on when it detects movement, and when people leave, it switches off after
the hold time is lapsed (30 seconds).
Applications: dim places such as basement parking, underpass
No Daylight Function
The hold time is set to 30 seconds, and LUX is set to 300
The light switches on when it detects movement, and it switches off after people leave at night
Applications: corridor, staircase
When the motion is detected with
sufficient daylight (>300LUX),
the light remains OFF.
When the motion is detected with
insufficient daylight (<300LUX),
the light switches ON.
After the last detection and the
present hold time (30 seconds)
elapsed, the light switches OFF.
When the motion is detected,
the sensor will switch on the light
to 100% brightness.
After the people leave the detection
area, the light remains at 100%
brightness within the hold time.
After the last detection and the
present hold time (30 seconds) is
elapsed, the light switches OFF.