7
SPECIFICATIONS:
9
TROUBLESHOOTING:
STATUS CAUSE REMEDY
Sync LED does not light
( Transmitter )
Sync LED does not stop
( Transmitter )
Alarm LED does not stop
( Receiver )
Alarm LED does not light even if
the infrared beam is obstructed.
( Receiver).
Weak Signal LED continues
to be blink.
( Receiver )
Alarm Ons and Offs
( Receiver )
No response on Alignment
Operation
1. Power is not on.
2. Poor wiring or breaking of wire, short.
1. Poor wiring on SYNC Signal, or breaking of wire, short.
2. Sync signal connected with wrong polarity.
3. Wrong Channel setting.
4. Two(2) Transmitters both setting as Master.
1. Alignment is not aligned correctly.
1. Alignment is not aligned correctly.
2. Transmitter and Receiver Installation distance exceed
required spec.
3. Infrared power on Transmitter set with Low Power.
4. Power source on Transmitter is too low to support
infrared signal.
1. The units setting on same Channel, however not facing
the same direction.
2. Alignment is not aligned correctly.
3. Transmitter and Receiver cover is dirty.
4. Power is too low to activate the relay.
1. Wrong Master Slave Switch setting.
2. Wrong Channel setting.
/
1. Connect the power source.
2. Check the wiring
1. Check the wiring of “ SYNC Signal “.
2. Check the polarity on Sync signal.
3. Check DIP-SW, Channel settings on Receiver.
4. Check DIP-SW, one Transmitter only allow one master.
1. Re-align Transmitter and Receiver.
1. Re-align Transmitter and Receiver.
2. Check the installation distance meet required spec.
3. Refer to the instruction for Infrared Power setting.
4. Check the power source on Transmitter.
1. Re-set the channel properly
2. Re-align Transmitter and Receiver.
3. Clean using a soft cloth.
4. Check the power source.
.
1. Wrong Channel (A-B) setting.
2. The Master Slave-1, 2, 3 setting on TX is different
from RX.
/
1. Check if the Channel (A-B) / DIP-SW setting is identical on
both TX and RX.
2. The order of Master Slave-1, 2, 3 should be identical on both
TX and RX.
/
1. Channel (A-B) setting should be identical on both TX and RX.
2. Master Slave 1, 2, 3 setting on TX and RX should be identical. /
Model No. Model No.
Items Items
Detection Range Response Time
Beam Adjustment
Mounting Positions
Functions
Ambient Temperature
Wiring
Environment Humidity
Weight
Optional Accessory
Standard
Accessories
Dimension (mm )
Max. Arrival Distance
Min. Arrival Distance
Supply Voltage
Current Consumption
( Transmitter )
Current Consumption
( Receiver )
Infrared Beam
Infrared Signal
Detection System
Alarm Output
Tamper Output
Attenuation
Indicator
Alarm LED
T/T Sync LED
Environmental
Output
5 (m)0
50 0 (m)
1 0 (m)
14 mA (max.) 16 mA (max.) 18 mA (max.)
a. Norm : 36mA (Max.)
b. When Environmental Relay operating : 55mA (Max.)
1. Two(2) channels ( CH_A / CH_B) is selectable.
2. Master / Slave-1, -2, -3 function is selectable.
3. Transmitter power ( H / L ) is selectable.
4. When the cover attached, all the LED would be off
for power saving.
7. ʺ Attenuation ʺ LED lights : when Environment
diagnostic function is initiated.
5. The Auto Gain Lock function only operates when the
front cover attached on the sensor body properly.
6. It's selectable to stack four(4) sensors on the same
pole and same direction facing.
4 Infrared Photoelectric Beams.
10 0 (m)
100 0 (m)
25 (m)
20 0 (m)
200 0 (m)
5 0 (m)
Infrared beam interruption system
Dry contact relay NC / NO. 0.2A / 28VDC
Interuption Time : 1.5 seconds
When the infrared signal dropping caused by
snow or fog.
heavy
Dry contact relay NC / NO A / 28VDC. 0.2
Micro SW Dry contact relay NC A / 28VDC
Action : When cover is detached.
. 0.2
When Beam Channel and Master / Slave setting
properly, Red LED would ON-OFF orderly.
Outdoor
Horizontal ,Vertical ±10°±90°
-25°C ~ +55°C
95%
Terminals
W3.94" x H15.35" x D3.93"
(W )100.0 x H390.0 x D99.8 mm
Red LED ( Receiver ) lights : when beam is alarm is initiated.
U-Shaped Brackets x 4、Attenuation Sheet x 2
x 8
Screws ( M4 x 30 mm ) x 8
Screws ( 4 x 20 Self tapping )
Heating Unit : HT-200
50 msec – 500 msec ( adjustable )
DC12V~30V ( Non-Polarity )
.
FDM ,TDM, 890m ( Pulsed Wave-length )
Yellow LED keeps ON and OFF, when the signal get
weaker, the ON-OFF get faster.
4PH-50TA
4PH-50TAI
4PH-50TA
4PH-50TAI
4PH-100TA
4PH-100TAI
4PH-100TA
4PH-100TAI
4PH-200TA
4PH-200TAI
4PH-200TA
4PH-200TAI
4PH-XXXTA : 4PH-XXXTAI : 1190 grams 2870 grams /