Inial Set Up
A few seconds aer powering the unit up for the rst me, or aer re-inialising it, the screen below will be displayed.
The only valid key which can be pressed is the ENTER key and the only way of stopping this screen from appearing is to com-
plete the setup roune.
Please note that, if you make a mistake and enter the wrong value in one of the steps, the ESC key can be used to go back a
step. You can go back as many steps as you like even right to the start of the setup roune if necessary.
The sengs that you enter are only saved aer you complete the last step so, providing you haven’t completed the nal step,
you can always start setup again by turning o the power and then powering up again.
The controller can also be re-inialised. See the ’Changing Parameters’ secon for instrucons on how to do this.
There are 21 steps in the setup roune and they are as follows:-
1. SELECT THE TYPE OF SHED: use the up and down arrows to cycle through the available opons, press the
ENTER key to accept.
2. ENTER THE NUMBER OF SETS OF CLAWS: Use the arrow keys to alter the value. Hint: When enter-
ing numbers use the le and right arrow keys to move the cursor and the up and down arrow keys to change the number
above the cursor.
3. SELECT THE TYPE OF PUMP: use the up and down arrows to cycle through the available opons, press the
ENTER key to accept.
4. SELECT THE TYPE OF TRANSDUCER: The default seng of “Sema Type 1” will almost always be correct
but the unit can also use other types of transducer including the Delaval/John Brooks transducer. Contact Sema for advice if
you are using something other than a Sema type 1 transducer.
5. ENTER THE MOTORS NAMEPLATE VOLTAGE: Use the arrow keys to alter the value.
6. ENTER THE MOTORS NAMEPLATE CURRENT: Use the arrow keys to alter the value.
7. ENTER THE MOTORS NAMEPLATE RPM: Use the arrow keys to alter the value. (Hint: If this is a belt