Securam BSL-0601A-D66 Manuel utilisateur

1
Document No.: BSL0601AD66
Version No.:V9.93140529 (E)
Model: BSL-0601A-D66
Biometric Controller
User’s manual
SecuRam Systems, Inc.

2
Contents
1. Enroll the first fingerprint for quick start (Level 3)………
2. Enroll the second fingerprint (Level 3)………………
3. Enroll additional fingerprints (Level 3)……………………
4. Set/Change User Code (Level 3).………………………..….
5. Enable User Code (Level 3)………………………………
6. Disable User Code (Level 3) …………………………………
7. Disable User (Level 3) ……………………………………...…
8. Enable User (Level 3) ……………………………………...….
9. Set time delay (Level 3) …………………………………..….
10. Duress Time Delay (Level 3) ………………………………
11. Unlock with an enrolled fingerprint or code (Level 3) …
12. Set number of locks (Level 3) ………………………….…...
13. Authorize access to locks (Level 3) ………………..….
14. Enable Sequence (Level 3) …………………………….…...
15. Delete one user (Level 3) ……………………………….......
16. Delete all users (Level 3) ………………………………..…..
17. Dual Mode (Level 3) ……………………………….…….
18. Set Time Lock (Level 3) ……………………………………
18..1 Set Timer…………………………………………………
18.2 Set Time Table……………………………………………
18..3 Set Holidays………………………………………………
19. See Timer (Level 3) ………………………………………
20. Wrong entry penalty (Level 3) …………………………….
21. Daylight savings (Level 3) ……………………………...
22.Max. door open time (Level 3) …………………………….
23.Audit trail (Level 3) …………………………….….….
24.System Info (Level 3) ………………………….…....
25.Set Security Level .………………………..…………….…..
26.Enroll the first fingerprint and its bound code for quick start (Level
2) …………………………………………….….
27.Enroll the second or additional fingerprints and its bound code for quick start (Level
2) …………………….…...
28.Set/Change the first code for quick start (Level 1) ……..
29.Enroll the second or additional codes (Level 1) .....
30Disable / Enable User (Level 1 & 2) ……………………....
31.Set time delay (Level 1 & 2) ……………………………..….
32.Unlock with an enrolled code (Level 1 & 2) ……….….….
33.Set number of locks (Level 1 & 2) …………………….…...
34.Authorize access to locks (Level 1 & 2) ………………
35.Enable Sequence (Level 1 & 2) ……………………….…...

3
36.Delete one user / all users (Level 1 & 2) ………….………
37.Dual Mode (Level 1 & 2) ………………………….…….
38.Set Time Lock (Level 1 & 2) ……………………………………
39.See Timer (Level 1 & 2) ………………………………………
40.Wrong entry penalty (Level 1 & 2) …………………….
41.Day light savings (Level 1 & 2) …………………………...
42.Max. door open time (Level 1 & 2) …………………….
43.Audit trail (Level 1 & 2) ………………………….….….
44.System Info (Level 1 & 2) …………………………….…..
Biometric EntryPad Electronic Actuator
1. Fingerprint Reader Window
2. LCD Screen
3. Digital Pad
4. “Reset” Button
ATTENTIONS:
● For indoor use only.
● Use one 9V alkaline battery. Always use an alkaline battery for high quality
performance; otherwise, controller might not work as well.
● LOW BATTERY ALERT: The display will alert low battery when battery voltage
reaches 5.4±0.2V PLEASE REPLACE THE BATTERY IMMEDIATELY.
● When the display alerts low battery, Biometric Controller can only be operated to
lock or unlock. Operations, such as enrolling, deleting or time-delay setting, are
not permitted.

4
Security Level Classification
Level 1: Entrypad can be operated by a code only.
Level 2: Entrypad must be operated by a fingerprint and its bound code. It is a
higher security level.
Level 3: Entrypad can be operated by a fingerprint or a code.
All enrolled users will be deleted when security level is changed. The first code
(ID No. 01) will be set to default 123456.
Note: Factory default security level is Level 3.
Battery Replacement Instructions
1) In the back of EntryPad you will see one 9V alkaline battery. Take the battery out
of the battery compartment.
2) Gently remove the connector by unsnapping it from the two terminals on the top
of the battery.
Never Pull on the Battery Leads.
3) Connect a new 9V alkaline battery to the battery clip.
4) Put the battery and the leads completely back into the battery compartment.
For mounting and wiring information refer to the installation instructions.
1.Enroll the first fingerprint for quick start (level 3)
In the back of entry pad, you’ll find a battery case. Install a brand new 9V alkaline battery.
Place your finger on the fingerprint reader window , the LCD screen will show” Start Enrolling
First User”. After the screen shows ”Place Finger”, place your finger on the fingerprint reader
window and hold.
The first fingerprint with an ID No. 01 is enrolled successfully.
The default code 123456 will be deleted when you unlock once with the finger of ID
01 successfully .
2.Enroll the second fingerprint (Level 3)
Press “Menu/OK”. The screen will show “Select Menu”. Press “▲” or “▼” to select “System
Menu”. Press “Menu/OK” again. Place the first enrolled finger on the reader window and
hold . After the fingerprint is verified successfully, press “▲” or “▼” to select “ Enroll New
User”.

5
Press “Menu/OK” again.
press “▲” or “▼” to select the ID NO. to be enrolled. For example: select ID No. 02. Press
“Menu/OK”.
Place your finger (different from the first one) on the fingerprint reader window and hold.
The second fingerprint, with an ID No. 02, is enrolled successfully.
Note: ID No. 01 and ID No. 02 are administrators .
3.Enroll additional fingerprints (Level 3)
Press “Menu/OK”. The screen will show “Select Menu”. Press “▲” or “▼” to select “System
Menu”. Press “Menu/OK” again
Place an enrolled administrator’s finger (ID No. 01 or 02) on the reader window and hold. After
the fingerprint is verified successfully, the LCD screen shows: “Select Menu”. press “▲” or “▼”
to select “ Enroll New User”.
Follow the above steps to enroll additional fingerprints.
4.Set/Change User Code (Level 3)
Press “Menu/OK”. The screen will show “Select Menu”. Press “▲” or “▼” to select “System
Menu”. Press “Menu/OK” again. Put the user’s finger (For example ID03) on the fingerprint
reader window and hold on, after the fingerprint was verified, press “▲” or “▼” to select
“Set/Change User code”, press “Menu/Ok”.
Enter a code (6 digits).
Enter the same code again.
When LCD screen shows :ID:03 code saved.
Now the new code is set or changed successfully .
Note:
● Administrators’ code can be set or changed directly.
● Non-administrators’ code should be enabled by the administrator first, then, the user can set or
change their code.
● If consecutive four digits of a new code (for example 512341)is same with one of the enrolled
codes(612345) , LCD screen will show : Code is similar .

6
5.Enable User Code (Level 3)
Press “Menu/OK”. The screen will show “Select Menu”. Press “▲” or “▼” to select “System
Menu”. Press “Menu/OK” again. Place an enrolled administrator’s finger (ID No. 01 or 02) on the
reader window and hold or enter the code of an administrator . After the fingerprint or code is
verified successfully, press “▲” or “▼” to select “Enable User Code”, press “Menu/Ok”.
press “▲” or “▼” to select the ID No. need to be enabled.
Press “Menu/Ok”
Now the code of ID No.3 user is enabled. Then set the code of ID No.3.
Press “Menu/Ok”, press “▲” or “▼” to select “System Menu”, get into the system menu with the
fingerprint of ID No.3 . Press “▲” or “▼” to select “Set/Chang User Code”.
Enter a new code(6 digits).
Enter the same code again.
When the LCD screen shows :ID:03 Code Saved , the code of ID:03 has been set successfully .
Note: If consecutive four digits of a new code (for example 512341)is same with one of the
enrolled codes(612345) , LCD screen will show : Code is similar .
6.Disable User Code (Level 3)
Press “Menu/OK”. The screen will show “Select Menu”. Press “▲” or “▼” to select “System
Menu”. Press “Menu/OK” again. Place an enrolled administrator’s finger (ID No. 01 or 02) on the
reader window and hold or enter the code of an administrator . After the fingerprint or code is
verified successfully, press “▲” or “▼” to select “Disable User Code”, press “Menu/OK”
Press “Menu/Ok”
ID No.3’s code disabled.
Note: This function can only disable the user’s code, not the user, the user can unlock the door by
fingerprint.
7.Disable User (Level 3)
Press “Menu/OK”. The screen will show “Select Menu”. Press “▲” or “▼” to select “System
Menu”. Press “Menu/OK” again. Place an enrolled administrator’s finger (ID No. 01 or 02) on the

7
reader window and hold or enter the code of an administrator . After the fingerprint or code is
verified successfully, Press “▲” or “▼” to select “Disable User”. Press “▲” or “▼” to select
the ID No. to disable (e.g. ID 03).
Press “Menu/OK”.
When the LCD screen shows :ID:03 disabled , The ID 03 is disabled successfully.
Note: Administrators cannot be disabled.
8. Enable User (Level 3)
Press “Menu/OK”. The screen will show “Select Menu”. Press “▲” or “▼” to select “System
Menu”. Press “Menu/OK” again, Place an enrolled administrator’s finger (ID No. 01 or 02) on the
reader window and hold or enter the code of an administrator . After the fingerprint or code is
verified successfully, press “▲” or “▼” to select “Enable User”.
Press “Menu/OK”.
Press “▲” or “▼” to select the ID No. to enable (e.g. ID 03).
Press “Menu/OK”.
Now the No. 03 user is enabled.
9. Set time delay (Level 3)
Press “Menu/OK”. The screen will show “Select Menu”. Press “▲” or “▼” to select “System
Menu”. Press “Menu/OK” again, Place an enrolled administrator’s finger (ID No. 01 or 02) on the
reader window and hold or enter the code of an administrator . After the fingerprint or code is
verified successfully, press “▲” or “▼” to select Set/Cancel Time Delay.
Press “Menu/OK”.
Press “▲” or “▼” to set time delay (00 to 99 min). Press “Menu/OK”.
Press “▲” or “▼” to select Time Window (01 to 15 min).

8
Press “Menu/OK”. Now the time delay is set successfully.
Attentions on Time Delay operations:
● Time Delay Override: At anytime ,TDO (time delay override) user can unlock the actuator
without time delay.
During Time Delay period, after ID No. 01 is verified successfully, the actuator will be
unlocked without delay.
● During Time Delay period, user can operate the entrypad, such as enrolling, deleting etc.,
but the actuator will not be unlocked.
● After the original time delay has been changed successfully, the time delay for the first time
unlocking the entrypad by an enrolled fingerprint is the same as the original one. The
new time delay will be effective afterwards.
● When changing Time Delay, if the period is longer than the previous one, the new time
delay will be effective during the next unlocking.
Note: When ID 01 is set to master ,time delay cannot be set.
10. Duress Time Delay (Level 3)
Press “Menu/OK”. The screen will show “Select Menu”. Press “▲” or “▼” to select “System
Menu”. Press “Menu/OK” again. Place an enrolled administrator’s finger (ID No. 01 or 02) on the
reader window and hold or enter the code of an administrator . After the fingerprint or code is
verified successfully, the LCD shows “Select Menu”, press “▲” or “▼” to select “Set Duress
Time Delay”. Press “Menu/OK”. Set the time between 0~99 minutes, press “Menu/OK”.
TM window :Press “▲” or “▼” to set the time between 01~15 minutes, press “Menu/OK”.
11.Unlock with an enrolled fingerprint or code
(
with Time Delay
)
(Level 3)
Verify an enrolled fingerprint or code . The LCD shows the ID No. followed by Time Delay.
For example:
Time Delay is set 10 minutes and Time Window 5 minutes.
Place an enrolled finger (ID: 03) on the fingerprint reader window and hold or enter an enrolled
code (ID: 03) until the LCD shows:
The entrypad will start counting up. The LCD screen flashes with the past time every 15 seconds.
When Time Delay finishes counting, two beeps will sound and the LCD screen will show:
The entrypad will start counting down again. The LCD screen flashes with remaining time every
15 seconds.
In the following 5 minutes, user can verify an enrolled fingerprint again to unlock the entrypad

9
with the LCD showing:
When the door is closed ,LCD screen will show “Door closed”.
Note:
TDO user can unlock the actuator without time delay. When the entrypad starts its Time Delay
process, user can operate the entrypad normally, but the actuator will not be unlocked even if the
verification is successful.
If no valid code or enrolled fingerprint are verified successfully during Time Window period, the
actuator will be locked until the end ,and then , the LCD will show:
12. Set number of locks (Level 3)
Press “Menu/OK”. The screen will show “Select Menu”. Press “▲” or “▼” to select “System
Menu”. Press “Menu/OK” again, Place an enrolled administrator’s finger (ID No. 01 or 02) on the
reader window and hold or enter the code of an administrator .
After the fingerprint or code is verified successfully, press “▲” or “▼” to select “Set number
of locks”.
Press “Menu/OK”.
Enter Mfc. code.
Press “▲” or “▼” to set number of locks.
Note: The default number of locks is 01. The maximum number of locks is 04. If the number of
locks is more than one, press the numbered button that corresponds with the lock to be opened.
Then, the lock will be unlocked automatically if verification is successful.
13. Authorize access to locks (Level 3)
Press “Menu/OK”. The screen will show “Select Menu”. Press “▲” or “▼” to select “System
Menu”. Press “Menu/OK” again, Place an enrolled administrator’s finger (ID No. 01 or 02) on the
reader window and hold or enter the code of an administrator . After the fingerprint or code is
verified successfully, press “▲” or “▼” to select “Authorize Locks”.

10
Press “Menu/OK”.
Press “▲” or “▼” to set the first ID in the group of users to be authorized. For example, to
authorize users with ID No. from 03 to 05.
Press “Menu/OK”.
Press “▲” or “▼” to set the last ID in the group of users to be authorized.
press “Menu/OK”.
“Lock 1234” means the number for each lock. “Auth. oxxx” shows whether the group has
authorization for each specified lock. Letter “o” means the group has authorization. Letter “x”
means the group does not.
For example: To authorize users with ID No. 03, 04 and 05 to open Lock 2, when the LCD screen
shows:
Press “1” to change “o” to “x”.
Press “2” to change “x” to “o”. Press “Menu/OK”.
Now the authorization is completed.
Note: Administrators can open all locks without authorization.
14.Enable sequence (Level 3)
Press “Menu/OK”. The screen will show “Select Menu”. Press “▲” or “▼” to select “System
Menu”. Press “Menu/OK” again. Place an enrolled administrator’s finger (ID No. 01 or 02) on the
reader window and hold or enter the code of an administrator . After the fingerprint or code is
verified successfully, the LCD screen shows “Select Menu”. Press “▲” or “▼”to select “Enable
Sequence”. Press “Menu/OK”.
If the number of locks is more than one, when unlocking in sequence is enabled.
Table des matières