SEC Sentry 822 PS Manuel utilisateur

1
Model 822 PS Pump Sentry
Owner's Manual
SEC America Corp.
SEC
Model 1622 PS Pump Sentry
November 5, 2019

2
Index
Page
Quick Installation & Battery Essentials………………….. 3
Precautions and Sequencing During Initial Hookup…. 4
How Pump Sentry Works……………………………..…….. 5
Important Safety Instructions…………………………….... 6
Safety Warnings……………………………………………… 7
Battery Precautions………………………………………….. 8
Battery Box……………………………………………………. 10
Installation Location…………………………………………. 10
Making Connections…………………………………………. 11
Installation Test………………………………………………. 11
Changing the Battery………………………………………… 12
Charger Functions.…………………………………………… 13
Uninterruptible Power Indicator …………………………… 13
Fan Operation ………………………………………………… 13
How to Discern when Pump Sentry
is Operational in Back Up Mode …………………………… 15
How to Discern when Pump Sentry
is Operational in Standby Mode …………………………... 15
Fuses …………………………………………………………… 15
Audible Alarm …………………………………………………. 15
Warranty……………………………………………………….. 16

3
Pump Sentry™
Models 822 PS & 1622 PS
INSTALLATION INSTRUCTIONS
QUICK INSTALLATION & BATTERY ESSENTIALS
Pump Sentry™ is designed to operate with an external battery or battery bank
whose nominal operating voltage is 12V, and whose single or combined A-
Hr. rating does not exceed 250 A-hr. A full recharge will take 13 hours or 30
hours for batteries of 100 A-hr. and 250 A-hr. respectively. Pump Sentry™
will maintain batteries at full charge while electricity is available. See page 13
of this manual to learn more about the charger function indicators.
BATTERY TYPE
Only batteries conforming to Battery Council International (BCI) group size
27 or larger are recommended (up to size 31). Only deep cycle batteries are
designed for the type of service which Pump Sentry™ requires. INSTALL
ONLY deep cycle batteries. (wet cell or AGM type) The marine-variety is
acceptable. DO NOT use car batteries. (See page 8 for some suggested
sources.)
BATTERY BOX
Your selected battery(ies) should be installed in a high quality plastic or metal
battery box that comes with a lid that is designed for said box. It is available
at the point of battery purchase.
BATTERY CABLES
Use only the cables furnished with Pump Sentry™ that are packaged in its
carton. They are equipped with the terminations necessary for reliable and
solid connection.
The ends with the blade terminals mate with the RED and BLACK battery
cable connectors on the Pump Sentry, while the other ends are furnished with
Ring terminals designed to fit over the wing nut posts of most batteries.

4
PRECAUTIONS & SEQUENCING DURING INITIAL HOOKUP
a) Secure Pump Sentry™ in its designated spot. It is recommended that
the unit be placed on a shelf or mounted to a wall.
b) Make sure the ON/OFF switch is in the OFF position and that the Pump
Sentry™ power cord is not plugged into an AC outlet.
c) Connect the blade end of the red battery cable supplied with the unit
into the red terminal block located adjacent to the fan air intake port.
Tighten the set screw of the block till the cable is well secured.
d) Perform the sequence in see with the black cable into the black terminal
block located adjacent to the red one.
e) Slide the battery into its protective box and place into its designated
spot sufficiently close to the Pump Sentry™ to allow the battery cables
to reach. DO NOT USE LONGER CABLES THAN THOSE
SUPPLIED WITH PUMP SENTRY™ as this may adversely affect the
time available for backup operation.
f) Connect the ring terminal end of the BLACK battery cable to the
battery NEGATIVE terminal.
g) Connect the ring terminal end of the RED battery battery cable to the
battery POSITIVE terminal. WARNING: WHEN DOING THIS STEP
THERE WILL BE A PERCEPTIVE SPARK AT THE TERMINAL
AS SOME COMPONENTS IN THE PUMP SENTRY™ CHARGE
UP. THIS IS NORMAL.
h) Once (g) is completed cover your battery box and secure the lid.
i) Plug the sump pump into the Pump Sentry™.
j) Plug the Pump Sentry™ into a wall outlet which has a minimum
capacity of 20A.
k) Turn ON the ON/OFF switch located to the left of the fan air intake
port.
l) Installation is complete.
INSTALLATION TEST
To make sure the installation is good, it should be tested per the following:
a) Raise the water level float switch controlling the pump causing the
pump to go ON.
b) Disconnect the Pump Sentry’s plug, mentioned in (j), from the wall
outlet. After a slight pause your sump pump should continue to operate.
If it does not, review steps (a) though (l) above.

5
The Pump Sentry™ is an innovative power station designed to operate your
pump during a power outage. When properly installed, it will provide many
years of reliable service.
To ensure that the Pump Sentry™ is optimally used and properly connected,
we recommend its installation be made by a licensed electrician or fully
qualified professional. Read these instructions completely and follow
directions carefully.
AC Utility Power
12 Volt
Battery
Figure 1
1622PS/822 PS
Pump +-
How The Pump Sentry Works
When electricity is present, the Pump Sentry™ charges a 12-volt battery and
surveys the power line. At the instant that a power failure occurs, the Pump
Sentry converts the energy stored in the battery to AC power to operate your
pump. When AC utility power is restored, the Pump Sentry automatically
switches your pump back to AC utility power, recharges the battery, and
monitors the power line.
While the Pump Sentry is a sophisticated electronic device, it should not be
expected to perform beyond its limitations, and extreme care should be taken
to insure safe operation within specifications.

6
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS – THIS MANUAL
CONTAINS IMPORTANT INSTRUCTIONS
FAILURE TO FOLLOW SAFETY INSTRUCTIONS AND
WARNINGS COULD RESULT IN INJURY OR DEATH
Read all the instructions
before installing or
operating the Pump Sentry.
ALWAYS disconnect
batteries and AC power
source from the Pump
Sentry before storing,
handling, or making any
adjustments to the unit.
Use Pump Sentry only as
described in this manual.
Any other use not
recommended by the
manufacturer may cause
fire, electric shock, or
injury.
Do Not sit or stand on the
Pump Sentry unit. Keep
children away!
Do Not place objects on the
Pump Sentry unit or allow
vents to become blocked.
Do Not smoke, use sparking
electrical devices, or allow
open flame near the unit
while working with it.
Do Not install Pump Sentry
in locations classified as
harzardous per N.E.C.
ANSI/NFPA 70 – 1984.
WARNING:
ELECTRICAL SHOCK
HAZARD
This unit has not been
evaluated for use outdoors.
Never operate Pump
Sentry outdoors.
Never operate Pump Sentry
with battery enclosure open.
Never operate Pump Sentry
in a wet location.
Never operate Pump Sentry
in a location where liquid or
moisture will come in
contact with, splash, or drip
into unit.
Do Not insert or allow
foreign objects to enter any
ventilation or exhaust
opening as this may cause
electrical shock and/or fire
hazard.

7
WARNING:
RISK OF ELECTRICAL
SHOCK
In the event of a short circuit,
grounding reduces the risk of
electrical shock by providing a
safe path to ground. The Pump
Sentry must be properly grounded.
The Pump Sentry is equipped with
a cord having a ground wire with
an appropriate three pronged plug.
The plug must be used with an
outlet that has been installed and
grounded in accordance with all
local electrical codes and
ordinances. Where a two pronged
wall outlet is encountered, it must
be replaced with a three pronged
outlet by a qualified Electrician to
reduce the risk of shock, the third
prong must not be cut off the plug.
DO NOT attempt to defeat this
safety feature.
Use Pump Sentry only with
adequate wiring that is up to
electrical code specifications.
Connect to properly grounded
outlets only.
WARNING:
RISK OF ELECTRICAL
SHOCK
The Pump Sentry is capable of,
and intended to generate electrical
voltage when unplugged from a
wall outlet or when AC power is
shut off.
Because Pump Sentry uses batteries to
generate 120 volts of AC power, both
the batteries and the power cord must be
disconnected to neutralize the Pump
Sentry. Failure to disconnect both the
batteries and the power cord could result
in electrical shock sufficient to cause
injury or death
FAILURE TO COMPLY WITH THE ABOVE WARNINGS COULD
RESULT IN INJURY OR DEATH

8
BATTERY PRECAUTIONS:
WARNING:
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS.
1. Servicing of batteries should
be performed or supervised
by a person knowledgeable
about batteries and the
required precautions. Keep
unauthorized personnel
away from batteries.
2. When replacing batteries,
use only models conforming
to Battery Council
International (BCI)
specifications for Group
size 27 or larger Deep
Cycle Marine batteries. At
the time of this publication,
the following model
batteries are typical of
minimum requirement. At
the time of purchase, verify
that the battery to be used
will be of BCI Group size
27 or larger .
Examples of Group 27
Deep Cycle Marine Battery
models:
Die Hard Model 27524
Exide Model NC-27
Interstate Model SRM-27
Metropolitan Model 27T-36
NAPA Model 8270
Larger BCI group sizes and
multiple-battery arrays may
also be used to increase
backup longevity.
3. CAUTION – Do Not
dispose of batteries in a fire.
The batteries might explode.
4. CAUTION – Do Not open
or mutilate the batteries.
Released electrolyte is
harmful to skin and eyes
CAUTION – A battery can
present a risk of electrical
shock and high short circuit
current. The following
precautions should be
observed when working on
batteries.
A. Remove Watches, Rings,
and other Jewelry and
metal objects.
B. Use tools with insulated
handles.
C. Do Not lay tools or metal
objects on top of
batteries.
D. Wear safety goggles and
a face shield.
5. CAUTION – The
electrolyte is a diluted
sulfuric acid mixture that is
Corrosive and harmful to
the skin and eyes. It is also
electrically conductive.
Observe the following rules

9
when working with the
electrolyte solution.
A. Wear full eye
protection and
clothing.
B. If electrolyte comes in
contact with the skin,
wash if off
immediately.
C. If electrolyte comes in
contact with the eyes,
flush thoroughly with
water and seek
medical attention
immediately.
6. CAUTION – Lead acid
batteries can present a risk
of fire and explosion
because they generate
hydrogen gases. The
following precautions must
be followed.
A. Do Not smoke when
near batteries.
B. Do Not cause sparks
or allow open flame
in the battery area.
C. Discharge static
electricity from your
body and clothing
before touching
batteries by first
touching a grounded
surface.
7. See Battery Manufacturers’ installation manual for additional
safety and maintenance instructions.

10
BATTERY BOX
Your selected battery should be
stored in a high quality plastic or
nylon battery box with a lid that is
designed for this purpose.
LOCATION
In a typical installation, the
Pump Sentry should be
mounted on the wall, above
the sump pit or crock, and in
accordance with all
applicable local electrical
codes.
It should be in close
proximity to a grounded AC
outlet and the battery box
(not closer than 2 feet).
VENTILATION
Do Not block either the fan
or the exit air ports of the
Pump Sentry. Allow at least
2 inches of air clearance on
all sides. Any room in which
the Pump Sentry is mounted
should have adequate
ventilation.
UNDER NO
CIRCUMSTANCES
Should the Pump Sentry be
mounted in a confined area or in
a sump pump pit or crock.
Pump Sentry is not only an
electrical appliance, but also
produces a potentially
dangerous and hazardous
electrical current even when
a power outage occurs. It is
safe when installed and used
properly. Keep children
away.
WARNING! The Pump Sentry has several components with
electrical contacts that switch electrical currents. Opening or
closing any of these electrical contacts can produce a spark that
could ignite an explosive air mixture. To prevent fire or
explosion, do not install the Pump Sentry in any area which
might contain flammable liquids or gases. Do not install Pump
Sentry in the same confined area as the battery box.
Ce manuel convient aux modèles suivants
1
Table des matières
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur