R-10 Remote Control Operation
Feature
1. With 10M signal cable.
2. The digital LCD is a multi-function controller, including Interval Set; Duration
Set;Output Volume Set;Timer Set;Output automatic; output manual; Wind
Set; DMX 512 Add. and so on.
Operation
1. Please connect the 10 M LCD wired multi-function remote control with 5-pin XLR
connector for Seany Haze Machine, then the LCD display of controller will show
"warming up! ”, the heating time keep moving any time, here the fog machine is in
warming status.
2. The haze machine heating is completed after 2 minutes, the digital LCD display
will show "Ready To fazer!", It denotes the machine begin to work.
Instructions for digital LCD Display to operation
1. Via the "Function" button, you can adjust the desired settings in the sub-
menus.After pressing the Function button once,the display shows"Man Vol Out",
Adjust the output volume with the Up/Down buttons. Pressing the "Function"
button twice, the display shows "Interval Set",Adjust the interval between each
fog emission (within the range of 1 to 200 seconds) with the Up/Down buttons.
Press Function button again to enter the next menu,"Duration Set".Adjust the
duration of each fog emission (within the range of 1 to 200 seconds) with the
Up/Down buttons.Press Function button again you enter to the menu "Volume
Out".You can set the fog output in % for the "Volume"function. Press the
Function button again to enter the next menu,"Wind Set".You can set the wind
output in % for "Wind" function with the Up/Dowen buttons.Press the Function
button to enter the last Sub-Menu "DMX 512 Add.". Adjust the desired DMX
-Add. With the Up/Down buttons.Setting the DMX 512 Add.should be
synchronization with the DMX 512 Address on the fog machine.
2.Press the "Timer" button to activate the timer function according to the
parameters set in the "Function" sub-menus. The display shows the adjusted
interval and the device counts the seconds down to "0". After that,the fog
emission is triggered at the main "Timer".If you wish to deactivate the timer
function, press the main "Timer"button once more.
3.Press the "Volume" button for immediate triggering of the fog emission at the
volume adjusted under menu"Volume Out".Press the "Volume"button once more
in order to stop the fog emission.
4.The "Manual" main menu only adjust the wind output with Up/Down button.
With power-down memory function
The digital LCD wired remote control has the power out memory of function, but the
power-down memory just memory the data of last time. Pull out the plug, whenever
you open the machine again, all data of inside the function status are unchanged.
(Note: It have no the work state memory.) It needs to set the various parameters again.
CONNECT DMX:
Pull down in the arrow direction to turn on. The address switch shown on the diagram is preset