Sculpt AXIS 1000 Manuel d'utilisation

1
1. PREFACE
2. SPECIFICATIONS AND CLEARANCES
3. PRELIMINARY INSTALL GUIDE
4. INSTALL GUIDE
5. OPERATION & MAINTENANCE
6. TEST REPORTS
7. WARRANTY
8. FINAL WORDS
I1000 |I1000DS
INSTALLATION & USER GUIDE
AXIS
NOTICE TO INSTALLER:
These instructions must be left with the owner, who should keep them for future use.

2
COMPLIANCE PLATE AND SERIAL NUMBER.
The instructions in this manual are recommendations only, the distributor and manufacturer bears no liability to the interpretation of these instructions.

3
Thank you for choosing Sculpt Fireplaces as your heater of choice.
Your replace is the result of careful design, artisan engineering and safety tests.
If it is properly installed, used and maintained, you may be sure that you will have an outstanding
heating feature in your home for years to come.
We advise you to read through this guide in order to become acquainted with the installation
methods specic to your replace.
It is recommended that this replace must be installed by a qualied and licensed trades
professional. You will nd in this guide answers to most of your questions, you should also
contact your retailer for any further information.
Before igniting your replace for the rst time, please carefully read this manual.
Follow @sculptreplacecollection on Instagram or like SculptFireplaceCollection on Facebook
and post your latest masterpiece installed with the hashtag #sculptres
We hope we’ve helped make you the envy of your friends this winter and years to come.
From all of us,
Sculpt Fireplace Collection
CONGRATULATIONS!

4
IMPORTANT
*Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilings
and 6 or more star rated buildings. Heating output may vary depending on factors such as building
characteristics, quality of insulation, type of rewood used and climate zone.
All dimensions shown are approximate. Check all dimensions accurately prior to installation. In line with
our policy of continuous improvement, we reserve the right to alter specications without notice.
All units comply and MUST be installed to Australian & New Zealand Standard AS/NZS 2918:2001.
When in use some parts may become hot. A suitable re guard is recommended where very young,
elderly or inrm are concerned.
ALL FIREPLACES IN THIS MANUAL CONFORM TO AUSTRALIAN AND NEW ZEALAND STANDARDS
AS/NZS 2918;2001 DOMESTIC SOLID FUEL BURNING APPLIANCES & AS/NZS 4012/4013(2014).
The instructions in this manual are recommendations only, the distributor and manufacturer bears no liability to the interpretation of these instructions.

5
INSTALLATION GUIDE
AXIS I1000 & I1000DS
This wood heater must be installed according to standard trade practices(as per AS/NZS 2918:2001),
according to the manufacturer’s instructions, in addition to local and national regulations (the most
restrictive of the regulations are applicable). This appliance must be installed by a qualied and licensed
professional.
The manufacturer is only an equipment designer and the following elements are not part of its
prerogatives:
• the design of heating installations
• thermal studies
• the creation of networks of heating distribution ducts
These are the domain of professional installers having the required qualications.
This appliance was designed and built in compliance with Australian and New Zealand standards. It
has been tested by an independent laboratory in order to validate the installation and commissioning
parameters. Any alterations to the appliance may cause a hazard and will void any warranties.
AXIS wood heaters are not work site incinerators. The combustion of any materials not listed in this
manual (pg, 18) may lead to damage to some of the appliance’s components.
1. PREFACE

6
2. SPECIFICATIONS
AXIS I1000 Single Sided
Solid steel rebox with re bricks
Up to 15 to 30 Squares*
1.2g/kg
66%
Secure Swing door opening system
3.6m
200m inner
Recommended for well insulated homes
10 year rebox warranty**
180kg
rear: 250mm sides: 450mm
Width: 1220mm Depth: 1055mm Thickness: 9mm (***refer pg, 7)
Material
Heating Capacity
Avg Emissions
Avg Efciency
Glass door
Minimum flue height
Internal flue sizes
Outside air kit
Warranty
Weight
Clearances
Minimum hearth dimensions***
*Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilings
and 6 or more star rated buildings. Heating output may vary depending on factors such as building
characteristics, quality of insulation, type of rewood used and climate zone.
**See warranty pg, 20 of the manual
100
50,65
58,8
Ø20
33,5
83
100
50,65
58,8
Ø20
33,5
83
FRONT SIDE
450mm
1000mm
833mm
350mm
587mm

7
2. SPECIFICATIONS
This appliance and flue were tested at the following clearances.
The Axis I1000 Single sided free standing appliance and Flo-met universal 8” flue system with a painted
solid casing between the appliance and ceiling conforming to joint Australian/New Zealand Standards
2918:2001, Appendix B.
A minimum 1055mm deep X 1220mm wide and 9mm non-combustible hearth should be used under the
appliance and in front of the appliance door when installing the appliance (see joint AS/NZs 2918:2001
3.3.2). The floor protector should extend 550mm in front of the appliance fuel loading door and be
placed centrally in the 1220mm width.
***The appliance must be elevated a minimum of 250mm above the hearth(on a non combustible
surface). If the heater is placed directly onto the hearth, the hearth dimensions required will be greater.
Please refer to AS/NZS 2918:2001 as per the minimum for a non-tested appliance.
Clearances & Hearth- Axis I1000 Single Sided
COMBUSTIBLE WALLS
COMBUSTIBLE WALLS
450MM
250MM
SWING DOOR
APPLIANCE
550MM
HEARTH
1055MM
1220MM
COMBUSTIBLE WALLS
COMBUSTIBLE WALLS
APPLIANCE
150MM 150MM
HEARTH
SWING DOOR
1055MM
1220MM
550MM
POSITION A PARALLEL POSITION
Diagram not to scale
POSITION B CORNER POSITION
Diagram not to scale

8
2. SPECIFICATIONS
AXIS I1000 DS Double Sided
Material
Heating Capacity
Avg Emissions
Avg Efciency
Glass door
Minimum flue height
Internal flue sizes
Outside air kit
Warranty
Weight
Clearances
Minimum hearth dimensions***
Solid steel rebox with re bricks
Up to 15 to 30 Squares*
1.0g/kg
62%
2X Secure swing door opening systems
3.6m
200mm inner
Recommended for well insulated homes
10 year rebox warranty**
180kg
1300mm in front & 450mm on either side
Width:1220mm Depth:1605mm Thickness: 9mm (***refer pg,7)
100
50,65
58,8
Ø20
33,5
83
100
50,65
58,8
Ø20
33,5
83
FRONT SIDE
1000mm
588mm
355mm
506mm
830mm
*Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilings
and 6 or more star rated buildings. Heating output may vary depending on factors such as building
characteristics, quality of insulation, type of rewood used and climate zone.
**See warranty pg, 20 of the manual

9
2. SPECIFICATIONS
This appliance and flue were tested at the following clearances.
The Axis I1000 Double free standing appliance and Flo-met universal 8” flue system with a painted
solid casing between the appliance and ceiling conforming to joint Australian/New Zealand Standards
2918:2001, Appendix B.
A minimum 1605mm deep X 1220mm wide and 9mm non-combustible hearth should be used under
the appliance and in front of each appliance door when installing the appliance (see joint AS/NZs
2918:2001 3.3.2). The floor protector should extend 550mm in front of the front both appliance fuel
loading doors and be placed centrally in the 1220mm width.
Clearances & Hearth- Axis I1000 DS Double Sided
COMBUSTIBLE WALLS
HEARTH
COMBUSTIBLE WALLS
CLEARANCE
APPLIANCE
1300MM
550MM550MM
1220MM
SWING DOOR
SWING DOOR
1605MM
450MM
POSITION A PARALLEL POSITION
Diagram not to scale
***The appliance must be elevated a minimum of 250mm above the hearth(on a non combustible
surface). If the heater is placed directly onto the hearth, the hearth dimensions required will be greater.
Please refer to AS/NZS 2918:2001 as per the minimum for a non-tested appliance.

10
It is the users duty to make themselves aware of and apply all national or more restrictive local
standards and instructions(AS/NZS 2918:2001).
IMPORTANT
Prior to unpacking and installation check that the appliance has not been damaged during transport.
Ensure you check the glass, the door(s), the damper operation and the door locking mechanism
Before any work is carried out, as per local and national regulations and laws, this appliance MUST be
installed by a licensed professional as per Australian and New Zealand Standards 2918:2001.
IMPORTANT WARNING
It is strictly forbidden to use any combustible materials (ie; wooden framing, plaster, etc) near or around
this appliance. Any exception from this rule is a health and safety hazard which will result in a non-
compliant installation and a void of warranties.
Electrical cables and components must not be placed in the vicinity of the appliance as it is a re
hazard.
3. PRELIMINARY INSTALL GUIDE
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Sculpt Cheminée intérieure

Sculpt
Sculpt AXIS Manuel d'utilisation

Sculpt
Sculpt AXIS I1000 Manuel d'utilisation

Sculpt
Sculpt SEGUIN MULTIVISION HYDRO 80 Manuel d'utilisation

Sculpt
Sculpt Seguin Europa 7 Manuel utilisateur

Sculpt
Sculpt AXIS Series Manuel d'utilisation

Sculpt
Sculpt JC BORDELET Tatiana 997 Manuel d'utilisation

Sculpt
Sculpt SEGUIN Aurore Manuel d'utilisation