SCIEX MSR 90 Manuel

SCIEX Dry Pump MSR 90
OPERATOR GUIDE
RUO-IDV-05-13982-A Original instructions

Disclaimer
This document is provided to customers who have purchased SCIEX equipment to use in
the operation of such SCIEX equipment. This document is copyright protected and any
reproduction of this document or any part of this document is strictly prohibited, except as
SCIEX may authorize in writing.
Software that may be described in this document is furnished under a license agreement. It
is against the law to copy, modify, or distribute the software on any medium, except as
specifically allowed in the license agreement. Furthermore, the license agreement may
prohibit the software from being disassembled, reverse engineered, or decompiled for any
purpose. Warranties are as stated therein.
Portions of this document may make reference to other manufacturers and/or their products,
which may contain parts whose names are registered as trademarks and/or function as
trademarks of their respective owners. Any such use is intended only to designate those
manufacturers' products as supplied by SCIEX for incorporation into its equipment and does
not imply any right and/or license to use or permit others to use such manufacturers' and/or
their product names as trademarks.
SCIEX warranties are limited to those express warranties provided at the time of sale or
license of its products and are the sole and exclusive representations, warranties, and
obligations of SCIEX. SCIEX makes no other warranty of any kind whatsoever, expressed or
implied, including without limitation, warranties of merchantability or fitness for a particular
purpose, whether arising from a statute or otherwise in law or from a course of dealing or
usage of trade, all of which are expressly disclaimed, and assumes no responsibility or
contingent liability, including indirect or consequential damages, for any use by the
purchaser or for any adverse circumstances arising therefrom.
Trademarks and/or registered trademarks mentioned herein, including associated logos, are
the property of AB Sciex Pte. Ltd., or their respective owners, in the United States and/or
certain other countries (see sciex.com/trademarks).
For Research Use Only. Not for use in Diagnostic Procedures
AB Sciex™ is being used under license.
Made in Czechia
Manufactured for:
AB Sciex LLC
500 Old Connecticut Path
Framingham, Massachusetts 01701
USA
Copyright notice
© 2023 DH Tech. Dev. Pte. Ltd.
Published: 1/23/2023

Contents
1. Safety and compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.1. Definition of Warnings and Cautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.2. Safety symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. General description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.1. Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2. Control panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.2.1. Auxiliary connector socket. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.3. Logic interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.4. Auto-run. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.5. Pump controller configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.6. Pump controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3. Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1. Operating and storage conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.2. Performance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.3. Materials exposed to gases pumped. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.4. Electrical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4. Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.1. Installation safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.2. Unpack and inspect. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.3. Mechanical installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.4. Leak test the system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.5. Electrical installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.5.1. Connect the electrical supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.6. Connection for remote control and monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5. Commission the pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6. Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.1. Operation safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.2. Operational modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.2.1. Manual control mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.3. Logic interface data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.4. Parallel control and monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.5. Analogue speed control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.6. Hardware configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.7. Operational modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.8. Start the pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
6.9. Shut down the pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
6.10. Restart the pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.11. Gas ballast adaptor fit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.12. Gas ballast operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
7. Maintenance and service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
SCIEX Dry Pump MSR 90
Page 3 of 40
Operator Guide
RUO-IDV-05-13982-A

7.1. General maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
7.2. Maintenance plan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
7.3. Inspect and clean the inlet strainer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
7.4. Clean the external fan grill. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
7.5. Electrical safety check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
7.6. Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
7.6.1. Return the equipment or components for service (SCIEX). . . . . . . . . . . . . . . . . . . . 35
8. Fault finding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
8.1. Alarm indicator codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
9. Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10. Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Operator Guide
RUO-IDV-05-13982-A
SCIEX Dry Pump MSR 90
Page 4 of 40

List of Figures
Figure 1: Pump features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 2: Control panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 3: Valve connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 4: Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 5: MSR 90 performance curve at 250 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 6: Speed vs Power graph. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 7: Logic interface connections - parallel control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 8: Logic interface connections - analogue speed control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 9: Analogue speed control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 10: Gas ballast open-close. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
SCIEX Dry Pump MSR 90
Page 5 of 40
Operator Guide
RUO-IDV-05-13982-A

1. Safety and compliance
For safe operation from the start, read these instructions carefully before you install or
commission the equipment and keep them safe for future use. Read all the safety instructions
in this section and the rest of this manual carefully and make sure that you obey these
instructions.
The instruction manual is an important safety document that we often deliver digitally. It is
your responsibility to keep the instruction manual available and visible while working with the
equipment. Please download the digital version of the instruction manual for use on your
device or print it if a device will not be available.
1.1. Definition of Warnings and Cautions
For safe operation from the start, read these instructions carefully before you install or
commission the equipment and keep them safe for future use.
Read all the safety instructions in this section and the rest of this manual carefully and make
sure that you obey these instructions. The equipment must only be operated and maintained
by trained personnel in the proper condition and as described in this instruction manual.
Obey local and state requirements and regulations. If you have any questions about safety,
operation or maintenance of the device, please contact our nearest subsidiary.
Important safety information is highlighted as warning and caution instructions which are
defined as follows. Different symbols are used according to the type of hazard.
WARNING:
If you do not obey a warning, there is a risk of injury or death.
CAUTION:
If you do not obey a caution, there is a risk of damage to equipment, related equipment or
process.
NOTICE:
Information about properties or instructions for an action which, if ignored, will cause
damage to the equipment.
We reserve the right to change the design and the stated data. The illustrations are not
binding.
1.2. Safety symbols
The safety symbols on the products show the areas where care and attention is necessary.
The safety symbols that we use on the product or in the product documentation have the
following meanings:
Operator Guide
RUO-IDV-05-13982-A
SCIEX Dry Pump MSR 90
Page 6 of 40

Warning/Caution
An appropriate safety instruction must be followed or caution to a potential
hazard exists.
Warning - Heavy object
Identifies a possible hazard from a heavy object.
Warning - Dangerous voltage
Identifies possible hazards from hazardous voltages.
Warning - Protective earth (ground)
Earth point for electrical equipment.
WEEE symbol
The equipment must be discarded carefully. Obey local and national regula-
tions for disposal of this equipment.
Warning - Use protective equipment
Use appropriate protective equipment for the task.
SCIEX Dry Pump MSR 90
Page 7 of 40
Operator Guide
RUO-IDV-05-13982-A

2. General description
2.1. Overview
WARNING: INCORRECT USE OF EQUIPMENT
Risk of injury or damage to the equipment. Incorrect use of the equipment can cause
damage to the equipment or injury to people. The user is responsible for the safe operation,
installation and monitoring of the system.
CAUTION: GAS BALLAST INSTALLATION
Risk of damage to the equipment. If water vapour is present within the system or is pumped
by the product the gas ballast must be used to prevent damage to the product. The gas
ballast should continue to be applied with the pump running, for at least 1 hour after the
water vapour source has been removed to enable the pump to dry.
The MSR 90 is a dry, multi-stage roots vacuum pump that offers high pumping speed in a
compact form. The pump is connected by a power cord and is designed for use on clean duty
applications.
The cord rating is:
Supply voltage (V) Current (A) Frequency (Hz)
200 ‑ 240 7 50 or 60
The pump is not designed for use with flammable, corrosive, toxic or other hazardous gases.
Gas or oxygen can mix in the pump system.
The dry pump can be used in either transient or steady state gas load conditions. The pump
can sustain operation with a maximum continuous power consumption of 850 W. If the gas
load causes this value to be exceeded, then the pump will temporarily slow down. If the load
is subsequently reduced; or the transient overload protection has recovered, then the pump
will return to full speed operation. Refer to Table: Performance data for information on
maximum inlet pressure.
Refer to Figure: Pump features, the system is supplied with a NW40 inlet port (1) and a
NW25 exhaust port (10).
The pump mechanism is operated by an electric motor driven by an internal pump controller.
The rotational elements of the pumping mechanism are simply supported at the end by
lubricated bearings. PFPE lubricant is used and this is contained in both the gearbox and
motor ends of the pump module. These are "sealed for life" and the lubricant does not need
to be replaced until the pump service interval is reached.
The system is air cooled by a fan installed internally in the pump enclosure. The pump has a
thermal protection device that will stop the motor if a thermal overload occurs, for example in
high ambient temperatures. You must restart the pump after the pump is cooled down.
The pump is designed to pump the residual gases used in high vacuum systems. The gases
are:
▪Air
▪Oxygen (O2) < 21% by volume
▪Nitrogen
▪Krypton
▪Argon
Operator Guide
RUO-IDV-05-13982-A
SCIEX Dry Pump MSR 90
Page 8 of 40

▪Helium
You can use the pump to pump water vapour. You must use the gas ballast when water
vapour is pumped. The water vapour must not condense in the pump.
Note:
Make sure that the water vapour does not condense inside the pump.
To use the pump for a gas that is not listed, contact the supplier for advice. Failure to contact
the supplier can invalidate the warranty of the pump. Do not use the pump for aggressive or
corrosive gases.
Figure 1 Pump features
1. Inlet port 2. Control dashboard
3. Gas ballast 4. Vibration isolators
5. Castors x 2 6. 15-way D-type connector
7. Auxiliary connector 8. Mains circuit breaker
9. Mains connector port 10. Exhaust port
11. Protective earth stud 12. Lifting eye positions
1. Inlet port 2. Control dashboard
3. Gas ballast 4. Vibration isolators
5. Castors x 2 6. 15-way D-type connector
7. Auxiliary connector 8. Mains circuit breaker
9. Mains connector port 10. Exhaust port
11. Protective earth stud 12. Lifting eye positions
SCIEX Dry Pump MSR 90
Page 9 of 40
Operator Guide
RUO-IDV-05-13982-A

2.2. Control panel
Figure 2 Control panel
1. Start button 2. Sleep button*
3. Standby increase button 4. Standby decrease button
5. Alarm indicator LED 6. Service indicator LED
7. Auto‑run indicator LED 8. Standby decrease indicator LED
9. Standby increase indicator LED 10. Standby indicator LED
11. Run indicator LED 12. Stop button
13. Power status LED
1. Start button 2. Sleep button*
3. Standby increase button 4. Standby decrease button
5. Alarm indicator LED 6. Service indicator LED
7. Auto‑run indicator LED 8. Standby decrease indicator LED
9. Standby increase indicator LED 10. Standby indicator LED
11. Run indicator LED 12. Stop button
13. Power status LED
* Enables STANDBY functionality
2.2.1. Auxiliary connector socket
An auxiliary control connection on the rear panel controls an optional inlet valve. This inlet
valve can be operated in parallel with the normal pump output signal. Refer to Figure: Pump
features, (7). The valve is usually closed and:
▪will open when the normal signal becomes active (pump at speed)
▪will close when you select the stop button or if there is a fault condition
The reaction time will be in line with the valve selection and the output signal is 24 V d.c.
Refer to Figure: Valve connector for polarity of the connector pins when the connector is
energized.
The auxiliary connector is regulated to 24 V d.c. to control the accessories. If the auxiliary
load current exceeds the value in Table: Auxiliary load currents, the output will shut down to
protect the pump controller. Refer to Table: Recommended mating connector for the
recommended mating plugs.
Operator Guide
RUO-IDV-05-13982-A
SCIEX Dry Pump MSR 90
Page 10 of 40
Table des matières
Autres manuels SCIEX Pompe à eau
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur