Schick Handel DMR18 Manuel utilisateur

DMR18
User Manual
Door Station
Please read this manual carefully before using the product you purchase, and keep it well for future
use.We reserve the right to modify the specication in this manual at any time without notice.
1 2 3
654
7 8 9
#0
*
RF CARD

1.Parts and Functions
2. Terminal Descriptions
Camera Lens
Night View LED
Speaker
Adjustable Camera
Connectiong Port
With rainy cover
350 mm
128 mm
1 2 3
654
7 8 9
#0
*
RF CARD
LCD Screen
ID Card Window
Digital Keypad
Microphone
12
3
L1
T/R -
CN-LK
T/R+
J/KMB JP-LK
Bus
SD Card Slot
EB+
EB-
N.O
LK+
LK-
+12V
L2
1 2 3
654
7 8 9
#0
*
RF CARD
12
3
12
3
• +12V:12VDCpoweroutput.
• LK-(GND):powerground.
• LK+(COM):commoncontactoftheRelay.
• NO.:normallyopencontactoftheRelay(refertoDTtechnicalguideforLockconnection
detailinformations).
• EB+:Exitbuttonconnectionport.
• EB-:Exitbutonconnectionport.
• JP-LK:Forelectroniclocksafetytypesetting(refertoDoorStationLockConnections).
• T/R-:USB-RS485communicationterminalnegative.
• T/R+: USB-RS485communicationterninalpositive.
• Bus(L1,L2):non-polaritybusline.

3.Door Station Mounting
1 2 3
4
7
5 6
Drill a hole and attach the
rainy cover to it
Attach screws to fix the
metal box
Attach the unit to the rainy
cover correctlly
Attach the baffle to protect
the unit from droping
The last view for all mounting
The view for rainy
cover after mounted
Adjust the camera angle and attach the
metal to the panel and wire correctly.
Camera
angle

4. Door Lock Connections
1. Internal Power Supply Mode
Usethepowerofthesystemtosupplyfortheelectroniclock,sothatthelockcanbe
connectedtothedoorstationdirectly,withoutanadditionalpowersupplyfortheelectroniclock.
Notethatthedoorstationcanonlyoutput12Vdcpower,thereforethekindoflockislimited.
• Theratedpowerofthelockmustbelessthan12Vdc300mAwhenusinginternalpower
supplymode
• TheGNDmustconnecttothenegativeofthelock,andtheCOMconnecttothepositive.
• Jumpersetto1-2positionforPower-to-Unlocksafetytype(Normally open mode);set
to2-3positionforPower-off-to-Unlocktype(Normally closed mode).Notethatthe
unlockrelaymodeissetontheParametertabofDTCONFIGsoftware.
• Ifdifferentunlockingtimeisneededtobeconfigured,theDTCONFIGsoftwarecanbe
usedtochangetheUnlock TimingontheParametertab(seetheprogramsection).
JP_LK
12V 300mA
Jumper set to 1-2 position
+
-+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
1
2
3
set to Normally open on the
Unlock Relay mode on DT-config
software.
A. Connection for Power-to-Unlock type:
12V 300mA
Jumper set to 2-3 position
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
+
-
set to Normally Closed on the
Unlock Relay mode on DT-config
software.
JP_LK
1
2
3
B. Connection for Power--off-to-Unlock type:

+
+
-
-
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Remove the Jumper
set to Normally Open on the
Unlock Relay mode on DT-config
software.(default)
JP_LK
1
2
3
Note: Cut off this line when
using external power supply
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Remove the Jumper
set to Normally Closed on the
Unlock Relay mode on DT-config
software.
+
+
-
-
JP_LK
1
2
3
Note: Cut off this line when
using external power supply
2. External Power Supply Mode
Whentheelectroniclockisover12Vdc,additionalpowersupplyforthelockisneeded.
• Thepowersupplyforthelockmustbelessthan48Vdc1.5A.
• TheJumpermustberemovedwhenusingexternalpowersupply.Thedefaultsettingis
Power-to-Unlocktype(Normally open mode),ifusePower-off-to-Unlocktype,change
theUnlockRelaymodetoNormally closed mode.Notethattheunlockrelaymodeis
setontheParametertabofDTCONFIGsoftware.
• Ifdifferentunlockingtimeisneededtobeconfigured,pleaseusetheDTCONFIG
softwaretochangethesettingontheParametertab(seetheprogramsection).
C. Connection for Power-to-Unlock type:
D. Connection for Power--off-to-Unlock type:

5. Door Station Congurations
1. About room code(address):
RoomCode(alsocalledroomaddress)isacodeassignedtoeachmonitor,toidentifydifferent
monitors;eachmonitorhaveauniqueroomcodeinonebuidling.TheroomCodeisstoredin
eachMonitor’sinnerEEPROMmemory,anddoesnotloseeventhemonitorispoweroff.
2. About Debug State:
TheDebugStateisyourstartingpointforusingalltheapplicationsonDMR18.
WhenDoorStationisin
standby,press'#'key
Press"2#"keytoexitoutthedebugstate.
input'9008',theninputthe
AdminCode.(66666666by
default)
DebugStatemenuislaunched
[ 9 0 0 8 ]
Please Input Password
1 2 3
654
7 8 9
#0
*
RF CARD
>> Debug State <<
1-# Tools
0-# Redial
2-# Exits
3. About Debug Tools:
DuringworkingatDebugState,press"1#"toentertoolspage,DebugToolsoverviewsis
shownasbelow:
1. Installer Setup
2. Setup
3. Card Memory
4. Online Monitors
5. Online Devices
6. Voltage Measure
Pres NO.
to select
*Back
Tools
>> Debug State <<
0-# Redial
2-# Exits
1-# Tools

Item Submenu
1. Installer Setup
1.IDCode[1]
2.UnlockTiming[05]
3.UnlockOutput[0]
4.CardMemory[0]
5.DoorplateMode
6.AudioOptions...
7.Parameters...
8.InstallerCode...
9.Default...
2. Setup
1.Language[1]
2.ToneSelect[03]
3.ToneVolume[08]
4.UnlockCode[1111]
5.DisplayMode
6.Clock...
7.SetupCode...
8.About...
9.Default...
3. Card Manage
1.AddCard...
2.DeleteByCard
3.DeleteByM.code
4.CardsInformation
5.Format
4. Online Monitors Tosearchtheonlinemonitors,inputthemonitorcode
numbertosearch
5. Online Devices Tosearchtheonlinedoorstations.Max.4doorstation
canbesearched
6. Voltage Measure Tocheckthevoltageofthemonitor,notethatthe
monitormustbeonline.
Table1:

Basic Tools Detail:
Item Description Factory
set
IDCode
Ifonlyonedoorstationisinstalledinthisbuilding,set
to1;
Ifmultidoorstationsareinstalled,primarydoorstation
mustbesetto1,andotherslavedoorstationsmust
besetfrom2to4.Notethatmax.4doorstationsis
availableinonebuilding
[1]
Single
UnlockTiming Tosetthetimethathowlongthedoorkeepsopen
whendoorisreleased.Rangefrom01to99seconds.
[05]
5seconds
UnlockOutput Tosettheunlockmodetomatchthecorresponding
lock.Randfrom0to1 0
CardManage Tosetthecardlocation.Ifsetto0,thecardissavedin
doorstation.Ifsetto1,thecardissavedinDT-IPC 0
DoorplateMode
Tosetthecallingmode.Ifsetto0,it'stheauto
mode,thatmeansthecallingwillbeactivateddirectly
afterinputting2digitscode.Ifsetto1,it'sthemanual
mode,thatmeansyoushouldpress"#"buttonto
activatethecallingafterinputtingthecode.
[0]
Automode
AudioOptions... Tosetthetalkingmode.Ifsetto0,handsfreemodeis
activated.Ifsetto1,handsetmodeisactivated. 0
Parameters... Toshowtheparameters,pleaserefertotable2.1
InstallerCode... Tochangedoorstationadministratorcode [66666666]
Default...
Notethisoperationisirreversible. Oncerestoreis
activated,allparameterswillreturntofactorydefault
settingexcepttheinformationofaccesscard.
Table2(InstallerSetup):

Item Description Factory
set
MonitorTiming Toshowthemonitortime,Rangefrom6sto600s 30s
SwitchTiming ToshowthesurveillancetimeforeachDoorStationor
CCTVcamera.Rangefrom6sto600s 40s
WaitTiming Toshowthecallingwaittime,Rangfrom10sto600s 30s
TalkTiming Toshowthelimitationtimeoftalking,Rangefrom10s
to600s 90s
Monitor&Speack
ToenableIndoorMonitorundermonitoringstatecan
speaktoDoorStationatsametime.Ifsetto1,talk
enabled;setto0,disabled.
Monitor&Unlock
ToenableMonitorsundermonitoringstatecanopen
thedooratthesametime.Ifsetto0,unlockfunction
isdisabled;Setto1,unlockisenable;Setto2,unlock
isenableandcloseatonce;Setto3,unlockisenable
andclosein5s.
[1]
RingNumbers
Toshowringtimeswhendoorstationcallsmonitor.4
optionsforchoice.Ifsetto0,ringonce.Ifsetto1,ring
twice.Ifsetto2,ringthreetimes.Ifsetto3,cyclering
[1]
NameListDisplay
Mode
Toshowthenamelistdisplaymode.Ifsetto0,it'sthe
DT-Configdisplaymode.Ifsetto1,it'stheSimulate
displaymode
[0]
WorkingMode Toshowtheworkingmode.Ifsetto0,it'stheapartment
systemmode.Ifsetto1,it'sthevillamode. [0]
Table2.1(Parameters):
Note:thissectionissetonDT-Congsoftware,formoredetailinformations,pleaserefertothe
DT-Congsoftwareuserinstructions.

Item Description Factory
set
Language
Tochangelanguage.thecodeformatis4digits.Pleaserefer
topart5,section10(changedoorstationlanguage)formore
detailinformations.
01
ToneSelect SelectthechimeofDoorStationincallingwaitstate,12
chordtunesareavailable,keyin01to12toselect. 03
ToneVolume Adjustthetonevolumefordooorstationincalling.Rangfrom
01~15 08
UnlockCode TochangeunlockcodeinCommonCodeUnlockmode,in
4-digitsformat.1111isthedefaultunlockcode. [1111]
DisplayMode
ToselecttheDoorStationscreenmenu.Ifsetto0,the
screendisplaysthevisitor'simagewhentalking.Ifsetto1,the
screendisplaysiconswhentalking.
[0]
Clock...
Tosetdateandtime.
Dateformat:ifsetto0,dateformatisDD/MM/YY,ifsetto
1,dateformatisMM/DD/YY.
Timeformat:ifsetto0,timeformatis24hourstandard.Ifset
to1,timeformatis12hourstandard.
SetupCode TochangetheProgramCode. [88888888]
About...
1.Hardwareversion---ToshowtheDoorStation(including
ACS)hardwareinformation
2.Softwareversion---ToshowtheDoorStation(including
ACS)softwareinformation
3.ManufactureDate---Toshowthemanufacturingdate
4.DialingCounts---Toshowthecalloperationcounts
5.CallsCounts---Toshowtheestablishedcallingcounts
6.UnlockCounts---Toshowtheunlockoperationcounts
7.StandbyVoltage---Toshowthevoltagethatthedoor
stationinstandby.
8.WorkingVoltage---Toshowthevoltagethatthedoor
stationinworking.
9.VideoStandard---PALorNTSCstandard
10.UI_CODE---ToshowtheUIbytecountsandcheckbox
11.MCM-VER---ToshowtheversionandlanguageforMCM
12.Updated---ToshowtheupdatedtimeforUI
Default... RestoreallSetupparameterstofactorydefaultsetting,Please
notethatthisoperationisanirreversible
Table3(Setup):
Table des matières
Langues :
Autres manuels Schick Handel Système d'interphone