Sanyo SHA TM64 AGB Manuel utilisateur

SHA TM64 AGB

3
Schedule Timer
Schedule Timer / SHA-TM64AGB
Operation Buttons
A: PROGRAM button
E: HOLIDAY button
C: CLEAR button
G: TIMER OFF button
D: Setting buttons
B: PROG. COPY buttons
F: CANCEL button
A: PROGRAM button Use to start setting programs and to enter program settings.
B: PROG. COPY buttons Use to copy programs to groups or specific days in a schedule.
C: CLEAR button Press to clear the settings of the currently displayed program.
•The current program is not cleared unless the button is pressed after pressing
the CLEAR button.
D: Setting buttons Use to make program settings and to set the present time.
Press to set groups for programmed operation.
Press to set today’s day and days of programmed operation.
Press to set the present time and times used in programmed operation.
Use to start/stop indoor units via the timer.
Use to enable/disable remote controller operation via the timer.
Use to set programmed operation trigger time.
•Program settings are not entered unless the button is pressed at the end of
setting operations.
E: HOLIDAY button Press to set and cancel holidays during a scheduled week of operation.
F: CANCEL button Press to cancel the current program setting operation, copying operation or holiday setting
operation. When the CANCEL button is held down for 2 seconds, the current setting
operation or copying operation is canceled and the normal display returns.
G: TIMER OFF button Press to turn the timer OFF when timer operation will not be used for a long period of time.
When this button is held down for 2 seconds, appears on the display. Programs
cannot be run until the button is again held down for 2 seconds.
Some of the above features are disabled when the unit is installed. If the button of a
disabled feature is pressed, appears on the display. For more information, contact
your dealer.

.
3
Schedule Timer
Display
CD
F
G
H
E
IJ
AB
A: Today’s day of the week ( ) Indicates today’s day of the week.
B: Program schedule indication ( ) Appears under days that are scheduled for program operation.
C: Holiday schedule indication ( ) Appears around scheduled holidays.
D: ERROR indication Displayed when a mistake is made during timer setting.
E: Timer program Displays set timer programs. Also, indicates the copy source/destination during
group program copying.
F: Group No. Up to 8 groups can be selected and displayed.
G: (Disabled Feature) indication Displayed if the selected feature was disabled during installation.
H: TIMER OFF indication Displayed when the timer has been turned OFF.
I: Copy mode indication Displayed when copying a program into a group or day of the schedule.
J: Present time Displays the present time on a 24-hour clock. Also, displays settings in the
various setting modes.
Using the Schedule Timer
To use the schedule timer, follow the steps below.
STEP1 Turn ON power to the air conditioner.
Turn ON power to the air conditioner connected to the schedule timer. The schedule timer performs initial
communications with the indoor units, during which blinks on the display.
NOTE
Do not turn off the power mains in heating and cooling seasons. (This keeps the crankcase heater electricity
turned on, which protects the compressor at startup.) If the air conditioner has been OFF for a long period of time,
turn on power 5 hours before starting operation.
STEP 2 Make the initial settings of the schedule timer.
Set the present time and today's day of the week. (Refer to page 3-88.)
STEP 3 Set up programs of the schedule timer.
Make settings for programmed operation. (Refer to page 3-100.)

3
Schedule Timer
Setting the Present Time
Set the present time. (Example: When the present time is 12:45)
STEP 1 Hold down the SET button and press the HH button to set the
hour.
The hour increases 1 hour at a time with each single press of the
HH button while the SET button is held down.
The hour scrolls rapidly when both the SET button and HH but-
ton are held down. (Example: To set 12:00, release the HH but-
ton when “12” is displayed.)
When the SET button is released, the hour is set and the indica-
tion changes from blinking to lighting.
NOTE
Pressing just the HH or MM button does not change the time.
STEP 2 Hold down the SET button and press the MM button to set the
minutes.
The minutes increase 1 minute at a time with each single press
of the MM button while the SET button is held down.
The minutes scroll rapidly when both the SET button and MM
button are held down. (Example: To set 00:45, release the MM
button when “45” is displayed.)
When the SET button is released, the minutes are set and the
indication changes from blinking to lighting.

.
3
Schedule Timer
Setting Today's Day of the Week
Set today's day of the week. (Example: When today is Wednesday)
STEP 1 Hold down the SET button and press the DAY button to set
today's day of the week.
blinks and moves 1 day at a time across the days of the week
with each single press of the DAY button while the SET button is
held down.
When the SET button is released, the day of the week is set and
the changes from blinking to lighted.
NOTE
Pressing just the DAY button does not change the day of the week.

3
Schedule Timer
Setting Up Programmed Operations
Correctly set the present time and today's day of the week.
Unless both are correctly set, the programs will not run as expected.
Up to 6 programmed operations can be set per day for each group and day
of the week.
A combination of the below operations can be set for each timer program.
– Air conditioner starting/stopping
– Remote controller operation enable/disable *1
To change the settings of an existing program, use the same procedure used
to set up a new program as below.
*1 The remote controller operation enable/disable setting is disabled depend-
ing on installation conditions. If so, appears on the display when the
button is pressed.
For more information, contact your dealer.
STEP 1 Press the PROGRAM button to select a group.
When the PROGRAM button is pressed, the group No. and to-
day's day of the week start blinking and the present time indica-
tion changes to a blinking “PG-1”.
Press the GROUP button to select a group for programmed op-
eration and then press the SET button.
NOTE
Group selection is disabled depending on installation conditions.
If so, proceed to the next step.
The number of selectable groups is set during installation.
STEP 2 Press the DAY button and select a day of the week for pro-
grammed operation.
When the SET button is pressed, the program schedule marker
changes from blinking to lighting and, at the same time,
the time set in program starts blinking. Also, the present time
indication changes to a blinking “PG-2”.
NOTE
The currently selected day of the week blinks slowly at this time.
Example settings

.
3
Schedule Timer
STEP 3 Set up the program and press the SET button.
Select timer operation with the (timer ON/ OFF) button
and (remote controller operation enable/disable) but-
ton. Then, set the trigger time with the HH and MM buttons, and
press the SET button.
When the SET button is pressed, the time set in program
changes from blinking to lighting and, at the same time, the time
set in program starts blinking.
NOTE
Every time the button is pressed, the timer indication
changes in the order of (ON) (OFF) no indication.
Every time the button is pressed, the remote controller
indication changes in the order of (enabled) (disabled) no
indication.
The remote control operation enable/disable setting is disabled
depending on installation conditions. In this case, only timer ON/
OFF can be set.
STEP 4 Set up programs
~
in the same way.
When the SET button is pressed, settings are automatically ar-
ranged in the order of earliest time first.
If the SET button is pressed without any new settings being
made in the program, program starts blinking again and set-
tings can be changed.
Similarly, if the SET button is pressed after setting up program
, program starts blinking again.
STEP 5 Press the PROGRAM button.
Program settings are entered and the normal display returns.
STEP 6 Set up programmed operation for other groups and days of the week in the same way.
Programs that have already been set up can be copied into other groups and days of the week. (Refer to page
3-93.)
NOTE
A “0:00” time setting is interpreted to mean 12:00 midnight.
To cancel program settings during program setup (while “PG-1” or “PG-2” is blinking on the display),
hold down the CANCEL button for more than 2 seconds. The normal display returns.
If settings are canceled without pressing the PROGRAM button, settings are not entered.

3
Schedule Timer
Setting Errors
If time is set as shown below while setting up a program, “ERROR” is displayed (the indication blinks).
Therefore, correct the time setting.
If Program Times are the Same
STEP 1 Every time the SET button is pressed, the setting mode switches between programmed operations of the same
time setting ( and in the above example), therefore select the time setting to correct.
STEP 2 Change the time setting with the HH and MM buttons so that the times are no longer the same.
STEP 3 Press the SET button and check “ERROR” is not displayed.
STEP 4 Press the PROGRAM button to end the setting mode.
Example of Time Settings That Do Not Cause Errors
The below time settings do not generate an error.
1) When ON and OFF times are staggered 2) When OFF time is earlier than ON time

.
3
Schedule Timer
How to Check Program Times
You can check the programmed times for each group and day of the week.
STEP 1 Press the GROUP button and select a group whose time you
want to check.
NOTE
Group selection is disabled depending on installation conditions.
If so, proceed to the next step.
STEP 2 Press the DAY button.
When the DAY button is pressed the first time, tomorrow's day of
the week starts blinking and the program settings for tomorrow
are displayed.
Every time the DAY button is pressed, the program settings
change in order of the days of the week.
Pressing the GROUP button displays the program settings of
another group on that same day.
STEP 3 STEP 3 End checking.
Press the CLEAR button. The normal display returns.
NOTE
Holding down the CANCEL button for more than 2 seconds also
returns the normal display.

3
Schedule Timer
How to Copy Program Times
You can copy the already set program of one day into another day (Day Program Copying), as well as copy the week pro-
grammed for one group into another group (Group Program Copying).
Example of Day Program Copying
(Copying Monday’s program into Tuesday)
Example of Group Program Copying
(Copying group No. 1’s program into group No. 2)
How to Copy Day Programs
STEP 1 Press the PROG. COPY DAY button.
The group No. and the over today's day start blinking and
“CP-1” starts blinking in the present time display area. In this
state, select a group in which to copy day programs, using the
GROUP button.
STEP 2 Select a source day program to copy.
Every time the DAY button is pressed, the moves across the
days of the week display, therefore select a day of the week that
will serve as the copy source.
Once having selected the copy source day, press the SET button
to set it. The display changes to key you to select a copy destina-
tion day.
STEP 3 Select a copy destination day.
When the schedule timer is ready for you to select a copy des-
tination day, “CP-2” starts blinking in the present time display
area, while the selected copy source day blinks in the days of the
week.
Therefore, select a day of the week as the copy destination, us-
ing the DAY button.
Table des matières
Autres manuels Sanyo Contrôleurs




















