Salter Brecknell WS Series Manuel utilisateur

Model WS Range
Model SBI-140 Indicator
User Manual
11 January 2007
AWT35-000056 Issue B
AWT35-000056

Model WS / SBI-140 Indicator
User Manual
2

Model WS / SBI-140 Indicator
User Manual
3
©Avery Berkel Limited 2006. All rights reserved.
The information contained herein is the property of Avery Berkel Limited and is supplied without liability for errors or omissions. No
part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing
restriction on reproduction and use extend to all media in which the information may be embodied.
Salter Brecknell is a trading name of Avery Berkel Limited

Model WS / SBI-140 Indicator
User Manual
4
Contents
WARNINGS.................................................................................................................................................. 5
Setup Instructions......................................................................................................................................... 6
Desk/Wall Bracket........................................................................................................................... 6
Power Supply .................................................................................................................................. 6
Installing Batteries........................................................................................................................... 7
Connecting Indicator to Platform..................................................................................................... 7
General Operating Instructions .................................................................................................................... 8
Display............................................................................................................................................. 8
Manual symbols............................................................................................................................... 9
Indicator Operation....................................................................................................................................... 9
Turning On and Zeroing the Indicator ............................................................................................. 9
Turning off the Indicator................................................................................................................... 9
Selecting Unit of Measure ............................................................................................................. 10
Removing the Tare........................................................................................................................ 10
Hold Function - Automatic Zero on Next Weigh............................................................................ 11
Hold Function - Manual Release................................................................................................... 11
Removing Hold.............................................................................................................................. 12
Print Function ................................................................................................................................ 12
Serial Interface Settings ................................................................................................................ 12
Error Messages............................................................................................................................. 13
User Configuration Settings........................................................................................................................ 14
Setup Controls............................................................................................................................... 14
Configuration Settings................................................................................................................... 15
Data Commands for Bi-directional Interface ................................................................................. 16
Display, Measurement and Service Settings.............................................................................................. 17
Scale setup and calibration ........................................................................................................... 17
Setup controls................................................................................................................................ 17
Service Settings............................................................................................................................. 17
Scale calibration............................................................................................................................ 19
Declarations of Compliance ....................................................................................................................... 20
United States................................................................................................................................. 20
Canada.......................................................................................................................................... 20
CE (Declaration of Conformity) ..................................................................................................... 20

Model WS / SBI-140 Indicator
User Manual
5
WARNINGS
Safe installation
Safety
THE EQUIPMENT CONTAINS NO USER SERVICEABLE COMPONENTS.
Installation and maintenance of the equipment must only be carried out by trained and authorised
personnel.
Electrical installation
The mains lead must be connected to a supply outlet with a protective earth contact. The
electrical supply at the socket outlet must provide over current protection of an appropriate rating.
For your protection all mains (110V or 230V) equipment used out of doors or in wet or damp
conditions should be supplied from a correctly fused source and protected by an approved
ground fault protection device (RCD, GFCI etc.)
IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN.
Routine maintenance
To avoid the possibility of electric shock or damage to the machine, always switch off the
machine and isolate from the power supply before carrying out any routine maintenance.
To avoid the risk of the machine falling, where applicable, ensure that it is placed securely on a
flat and level surface.
Safe use
Caution – Cleaning the indicator/weigh head
Harsh abrasives, solvents, scouring cleaners and alkaline cleaning solutions, such as washing
soda, should not be used especially on the display windows. Under no circumstances should you
attempt to wipe the inside of the machine.
The outside of standard products may be wiped down with a clean cloth, moistened with water
containing a small amount of washing up liquid.
The outside of products waterproofed to IP65, IP66 and IP67 may be washed down with water
containing a small amount of proprietary detergent.
Training
Do not attempt to carry out any procedure on a machine unless you have received the
appropriate training or read the Instruction Manual.
EMC compliance
The following may be applicable to your machine.
WARNING:
This is a class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.

Model WS / SBI-140 Indicator
User Manual
6
Setup Instructions
Desk/Wall Bracket
By changing the angle blocks as shown below, the indicator bracket can be converted into a wall
mounting bracket.
Power Supply

Model WS / SBI-140 Indicator
User Manual
7
Installing Batteries
Connecting Indicator to Platform
If necessary, wire the cable attached to the base as shown.

Model WS / SBI-140 Indicator
User Manual
8
General Operating Instructions
Display
Function Keys Annunciators
On/Off/Zero
Activate the tare
Select unit
Hold/Print
Centre of zero
Net weight displayed
Hold activated
kg, lb, oz Active unit of measure
Scale in motion

Model WS / SBI-140 Indicator
User Manual
9
Manual symbols
Short key press
Multiple key press
Long key press
Indicator Operation
Turning On and Zeroing the Indicator
1.
2.
Turning off the Indicator

Model WS / SBI-140 Indicator
User Manual
10
Selecting Unit of Measure
Using the Tare
1.
2.
3.
4.
Removing the Tare
.
kg →lb →lb.oz.
Ce manuel convient aux modèles suivants
1
Table des matières
Manuels Écran tactile populaires d'autres marques

IBASE Technology
IBASE Technology ASTUT-152-RE1S Manuel utilisateur

YASKAWA
YASKAWA TP 610C Manuel utilisateur

B&R
B&R Power Panel C Series Manuel utilisateur

Beijer Electronics
Beijer Electronics X2 control Manuel utilisateur

AXIOMTEK
AXIOMTEK GOT321W-521 Manuel utilisateur

TRIDONIC.ATCO
TRIDONIC.ATCO x-touchBOX Manuel utilisateur