Contents
1. Preparations
2. Installation
3. Installation troubleshooting
4. Manual adjustment mode
5. Optional features
• AUX-connection
• Water leakage sensor
Warnings
Follow these instructions carefully and
pay particular attention to the instruc-
tions marked in the following way:
ѥWARNING
Follow instructions marked with a
warning accurately to prevent injury
to persons and damage to property.
⚐ATTENTION
Follow instructions marked with a
note carefully to prevent damage to
property.
ѧHINT
Hints give you useful advice on using
the appliance.
1. Preparations
ѥWARNING
Read user and installation manual be-
fore using or installing the appliance
Install and check the application ac-
cording to the instructions. Safera is
not liable for any damage or expenses
caused by inappropriate installation.
1.2 Package content
Check that the Stove Guard is compat-
ible with the cooker (see section 1.1).
If the connection cord is damaged, it
must be replaced by the service per-
sonnel of the manufacturer or their
representative to avoid hazards.
All electrical connections must be
carried out by a qualiied electrician.
⚐ATTENTION
If the appliance was stored in a cold
space, it must be allowed to warm
up to room temperature before con-
necting it to mains power.
1.1 Compatibility
Safera Stove Guard is compatible with
most electrical cookers, hobs and ovens
meant for household use:
• Traditional cast-iron cookers and hobs
• Ceramic cookers and hobs
• Induction cookers and hobs
• Cookers and hobs equipped with a
timer, afterheat indicator, child proof
lock or integrated switch-o system
Safera Aurora is compatible with cook-
ers no wider than 90 cm. See compat-
ible kitchen layouts in chapter 2 and
installation step 2/3.
Power control unit Ⓒ (various
models available)
Sensor unit Ⓐ with mounting
bracket Ⓑ and 4 x batteries
(AA/LR6)
User and Installation
Guides
Remote control Ⓓ
with battery CR 2032
Mounting screws (2x)
ѥWARNING
Please contact your vendor if you notice
anything unusual about the appliance.
Check the product and the contents of the package before installation:
❶ ❷
❹
❺
❻
❶Adjustment button 1
❷Adjustment button 2
❸OK-button
❹Indicator light
❺Mains voltage indicator (optional)
❻Sensors
ѧHINT
The sensor unit and the remote con-
trol have identical button conigura-
tions so you may use either one to op-
erate all functions of the stove guard.

54
2. Installation - Step 1/3 Mount the Power Control Unit Ⓒ
PCU6.1P
1-phase, 3-pin plug OUT.
See pages 12-13.
PCU6.3P
Perilex-connectors.
See pages 8-9.
PCU6.1F
Fixed 1-phase connection.
See pages 10-11.
PCU6.3F
Fixed 3-phase connection.
See pages 6-7.
PCU6.1S
Schuko-connectors.
See pages 14-15.
Install the power control unit Ⓒ according to the following instructions.

76
PCU6.3F - Installation
Fixed 3-phase connection. OFF
1
Optional
AUX and
water sensor
connections.
See chapter 5.
2
6
4
3
4xA
A
A
A
B
2xB
ѥWARNING
Make sure that there is no power sup-
ply to the cooker and the oven by re-
moving their fuses. Also ensure that
the cooker is switched o.
OUT-wires are always energized when
the power control unit is connected
to the mains power. If a wire is loose,
it must be properly covered.
IN
5 x 2,5 mm2
ON
7
42 mm
239 mm
113 mm
OUTIN
PE
N
L1
L2
L3
PE
N
L
L
L
MAX 16A
MAX 16A
MAX 16A
MICRO DISCONNECTION
225,5 mm
78 mm
60 mm
60 mm
95 mm
L1
L2
L3
OUT
IN
OUT
IN
OUT
IN
N
PE
OUT
5 x 2,5 mm2
5
IN
Phase order can be freely chosen. If only two phases
are used, connect them to the terminals L2 and L3.
Do not install the power control unit
where it will be exposed to excessive
heat: See operational ambient tem-
perature on the power control unit Ⓒ.
⚐ATTENTION
Install the power control unit Ⓒ so
that it is not exposed to moisture.
Check that all cables can move freely.
If you are replacing the cooker or the
power control unit, see chapter 4
manual adjustment mode.

98
225,5 mm
95 mm
L = 700 mm
51 mm
+ Perilex
239 mm
113 mm
OUTIN
PE
N
L1
L2
L3
PE
N
L
L
L
MAX 16A
MAX 16A
MAX 16A
MICRO DISCONNECTION
PCU6.3P - Installation
3-phase, Perilex-connectors.
Optional
AUX and
water sensor
connections.
See chapter 5.
A
Mount the power con-
trol unit Ⓒ on the wall
behind the cooker or
into the cabinet next to
the cooker.
2
4xA
A
A
3
OUT
IN
ON
4
OFF
1
ѥWARNING
Make sure that there is no power sup-
ply to the cooker and the oven by re-
moving their fuses. Also ensure that
the cooker is switched o.
OUT-wires are always energized when
the power control unit is connected
to the mains power. If a wire is loose,
it must be properly covered.
Do not install the power control unit
where it will be exposed to excessive
heat: See operational ambient tem-
perature on the power control unit Ⓒ.
⚐ATTENTION
Install the power control unit Ⓒ so
that it is not exposed to moisture.
Check that all cables can move freely.
If you are replacing the cooker or the
power control unit, see chapter 4
manual adjustment mode.

1110
PCU6.1F - INSTALLATION
Fixed 1-phase connection.
IN
3 x 6 mm2
OFF
1
Optional
AUX and
water sensor
connections.
See chapter 5.
ON
7
2
6
4xA
A
A
A
B
42xB
3
* Check speciications on the cover
of the power control unit.
OUTIN
PE
L/N
L
PE
N
L
230 V MAX. 25 / 32 A *
MICRO DISCONNECTION
42 mm
239 mm
113 mm
225,5 mm
78 mm
60 mm
60 mm
95 mm
5
OUT
3 x 6 mm2
L OUT
N
N
L
OUT
IN
IN
PE
X
ѥWARNING
Make sure that there is no power sup-
ply to the cooker and the oven by re-
moving their fuses. Also ensure that
the cooker is switched o.
OUT-wires are always energized when
the power control unit is connected
to the mains power. If a wire is loose,
it must be properly covered.
Do not install the power control unit
where it will be exposed to excessive
heat: See operational ambient tem-
perature on the power control unit Ⓒ.
⚐ATTENTION
Install the power control unit Ⓒ so
that it is not exposed to moisture.
Check that all cables can move freely.
If you are replacing the cooker or the
power control unit, see chapter 4
manual adjustment mode.

1312
PCU6.1P - Installation
1-phase, 3-pin plug.
Optional
AUX and water
sensor connections.
See chapter 5.
4
3
6
4xA A
A
A
B
2xB
Connect
the stove
with 3-pin
plug.
7
2
ON
8
OFF
1
239 mm
40 mm
113 mm
* Check speciications on the cover
of the power control unit.
OUTIN
PE
L/N
L
PE
N
L
230 V MAX. 25 / 32 A *
MICRO DISCONNECTION
226 mm
99 mm
95 mm
L
N/L
PE
IN
5
ѥWARNING
Make sure that there is no power sup-
ply to the cooker and the oven by re-
moving their fuses. Also ensure that
the cooker is switched o.
OUT-wires are always energized when
the power control unit is connected
to the mains power. If a wire is loose,
it must be properly covered.
Do not install the power control unit
where it will be exposed to excessive
heat: See operational ambient tem-
perature on the power control unit Ⓒ.
⚐ATTENTION
Install the power control unit Ⓒ so
that it is not exposed to moisture.
Check that all cables can move freely.
If you are replacing the cooker or the
power control unit, see chapter 4
manual adjustment mode.

1514
PCU6.1S - Installation
1-phase, Schuko-connectors.
Optional
AUX and
water sensor
connections.
See chapter
5.
A
A
A
Mount the power control unit Ⓒ on
the wall behind the cooker or into the
cabinet next to the cooker.
2
4xA
3
OUT
IN
ON
4
OFF
1
225,5 mm
95 mm
OUTIN
PE
L/N
L
PE
N
L
230 V MAX. 16 A
MICRO DISCONNECTION
ѥWARNING
Make sure that there is no power sup-
ply to the cooker and the oven by re-
moving their fuses. Also ensure that
the cooker is switched o.
OUT-wires are always energized when
the power control unit is connected
to the mains power. If a wire is loose,
it must be properly covered.
Do not install the power control unit
where it will be exposed to excessive
heat: See operational ambient tem-
perature on the power control unit Ⓒ.
⚐ATTENTION
Install the power control unit Ⓒ so
that it is not exposed to moisture.
Check that all cables can move freely.
If you are replacing the cooker or the
power control unit, see chapter 4
manual adjustment mode.

1716
45°
Sensor
view 35°
10°
2. Installation - Step 2/3 Mount the Sensor unit Ⓐ
Example 3:
The user of the cooker is blocking the
sensor’s sight to the cooktop.
Example 1:
A tall object (e.g. downdraft hood) is
blocking the sensor’s sight to the cook-
top.
Example 2:
A cooker hood is blocking the sensor’s
sight to the cooktop.
Notice the sensor direction and viewing angle: Ensure that there are no obstacles blocking the sensor view:
45°
Sensor view 35°
10°
ѥWARNING
Ensure that the sensor unit has clear line of sight to the whole cooktop and that
there are no obstacles blocking its view. Incorrect installation may cause the stove
guard not to react to cooking hazards.
Do not place hot items or other appliances with hot surfaces (e.g. toasters or
grills) in close proximity of the cooktop, because they may interfere the sensor.

1918
2. Installation - Step 2/3 Mount the Sensor unit Ⓐ
ѥWARNING
Safera Aurora is compatible with
cookers no wider than 90 cm.
Sloped ceiling 5...18° (1:3)
If the ceiling in the kitchen is sloped, see
installation instruction on pages 20-21.
518°
(1:3)
Leveled ceiling 0...5°
If the ceiling in the kitchen is level, see
installation instruction on pages 18-19.
05°
Max. 2,6 m Max. 2,6 m
Choose and follow the mounting instructions based on your kitchen ceiling angle:
ѥWARNING
Safera Aurora is compatible with
cookers no wider than 90 cm.
Autres manuels pour PCU6.3-F
4
Ce manuel convient aux modèles suivants
9
Table des matières
Autres manuels SAFERA Capteur de sécurité