General Safety Summary
Carefully read the following safety precautions to avoid any personal injuries
or damages to the instrument and any products connected to it. To avoid
potential hazards, please use the instrument as specified.
Only the qualified technician can service the instrument.
Avoid Fire or Personal Injury
Use Proper Power Line
Use only the special power line of the instrument which approved by local
state.
Ground the Instrument
The instrument is grounded through the protective terra conductor of the
power line. To avoid electric shock, the ground conductor must be connected
to the earth. Make sure the instrument is grounded correctly before connecting
its input or output terminals.
Connect the Signal Wire Correctly
The potential of the signal wire is equal to the earth, so do not connect the
signal wire to a high voltage. Do not touch the exposed contacts or
components.
Observe All Terminal Ratings
To avoid fire or electric shock, please observe all ratings and sign instruction
on the instrument. Before connecting the instrument, please read the manual
carefully to gain more information about the ratings.
Do not Operate with Suspected Failures
If you suspect that the product is damaged, please let a qualified service
personnel check it.
Avoid Circuit or Wire Exposure
Do not touch exposed contacts or components when the power is on.
Do not operate in wet/damp conditions.
Do not operate in an explosive atmosphere.
Keep the surface of the instrument clean and dry.

4
Safety Terms and Symbols
Terms used on the instrument. Terms may appear on the instrument:
DANGER: Indicates an injury or hazard that may immediately happen.
WARNING: Indicates an injury or hazard that may not immediately happen.
CAUTIO: Indicates that a potential damage to the instrument or other property
might occur.
Symbols used on the instrument. Symbols may appear on the instrument:
Hazardous Protective Warning Chassis Power
Voltage Earth Ground Ground Switch

5
Adjust the Handle
When using the generator, users can adjust the handle to a
position which make it easier to operate and observe.
Adjust the Handle
Carrying Position
Horizontal Position

6
The Front Panel
The picture below shows the front panel composition:
1. Power Key
This key is used to turn on/turn off the generator. When the
power key is off, the generator is in the power off state.
2. USB Host
The generator supports USB disk of FAT format. It’s used to
read waveforms or status files from a U disk or to store the
current state of the instrument to the U disk.
3. LCD Display
S
4. Waveform Option
Area
5. Number Keys
数字键
6. Knob
1. Power Key
电源键
11. Menu Keys
2. USB
Host
7. Arrow
Keys
8. CH1 Control/Output Port
输出端
9. CH2 Control/Output Port
输出端
10. Mode/Utility Function Keys
功能键

7
3. LCD Display
The generator is equipped with a 4.3 inch’TFT-LCD display
which display current function menu, parameter settings,
system state, promptings and so forth.
4. Waveform Option
Waveforms ----Sine
Provide sine waveform output which ranges from 1μHz to
160MHz.
The key backlight will turn on when the key is selected.
The “Frequency/Period”, “Amplitude/High level”, “Offset/Low
level”, “Phase” of the sine waveform can be adjusted.
Waveforms ----Square
Provide square waveform output which ranges from 1μHz to
50MHz.
The key backlight will turn on when the key is selected..
The “Frequency/Period”, “Amplitude/High level”, “Offset/Low
level”, “Phase” and “Duty” of the square waveform can be
adjusted.
Waveforms ----Ramp
Provide ramp waveform output which ranges from 1μHz to
4MHz.

8
The key backlight will turn on when the key is
selected.
The “Frequency/Period”, “Amplitude/High level”, “Offset/Low
level”, “Phase” and “Symmetry” of the ramp waveform can
be adjusted.
Waveforms ----Pulse
Provide pulse waveform output which ranges from 1μHz to
40MHzt.
The key backlight will turn on when the key is selected.
The “Frequency/Period”, “Amplitude/High level”, “Offset/Low
level”, “Pulse width/” , “Rise/Fall”and “Delay” of the pulse
waveform can be adjusted.
Waveforms ----Noise
Provide gauss white noise output with a bandwidth of 100MHz
The key backlight will turn on when the key is selected.
The “Variance” and “”Mean” of the noise signal can be
adjusted.

9
Waveforms ---- Arb
Provide arbitrary waveform output which ranges from 1μHz to
40MHz
It can output 36 kinds of waveforms: Cardiac, Sinc, ExpRise
and ExpFall Etc. It can also output the arbitrary waveforms
from the U disk.
Users can edit arbitrary waveform through EasyWave and
down load them to the instrument.
The key backlight will turn on when the key is selected.
The “Frequency/Period”, “Amplitude/High level”, “Offset/Low
level”, “Phase” of the arbitrary waveform can be adjusted.
5. Number Keys
Those keys, including numbers from 0 to 9, radix points “.”,
symbol keys “+/-”, are used to input parameters. Note :To enter
a negative number, you need to enter a symbol ”-“before.
6. Knob
It is used to increase (clockwise) or decrease (anticlockwise)
current outstanding numerical value when setting parameters.
Switch off characters in the soft keyboard when inputting a file
name.

10
7. Arrow Keys
When using knob to set parameters, it is used to switch the
place of numerical value.
When inputting a file name, it is used to move the position of
cursor.
When saving or reading files, it is used to choose a position to
save a file or choose a file to be read.
8. CH1 Control/Output Key
CH1 :To turn on/off CH1 output ensuring load, polarity and
eqphse are set.
BNC connector and its nominal output impedance is 50Ω
When turned on CH1 (illuminated), output waveform from CH1
is displayed.
9. CH2 Control/Output Key
CH2 to turn on/off CH2 output, use this button ensuring load,
polarity and eqphse are set.
BNC connector impedance is 50Ω
When turned on CH2 (illuminated), output waveform from CH2
is displayed.