ROWAN ELECTRIC APPLIANCE OL12D-D023B Manuel utilisateur

INSTRUCTION MANUAL
DEHUMIDIFIER
Item NO:D4212B
Applicable Model:OL12D-D023B
Please keep this manual carefully for further reference!
Thank you for selecting our dehumidifier. Be sure to read this manual carefully
before using it. Any questions, please contact the professional service for help.


CONTENT
CAUTIONS................................................................................................................... 1
PARAMETERS............................................................................................................ 2
FEATURES.................................................................................................................. 2
PRODUCT DESCRIPTION........................................................................................3
DIGITAL DISPLAY...................................................................................................... 4
OPERATIONS............................................................................................................. 4
MAINTENANCE...........................................................................................................7
TROUBLE SHOOTING............................................................................................ 10

1
CAUTIONS
Please read the operating instructions carefully before using your
dehumidifier for the first time.
1Install the unit on the flat and hard floor to diminish vibration or noise.
2.Never immerse the unit in water or other liquids.
3.Never operate the unit if the cable or other connector is damaged, or something
abnormal may happen, please call customer service for help.
4.Disconnect the unit from power supply when it is not in use, or before relocating or
cleaning it.
5.Operate the unit only at the voltage specified.
6.The unit is for indoor use only. Don’t use it for other purposes.
7.Do not put heavy objects on the appliance.
8.Do not tip the unit to any side as spilled water may damage the appliance.
9.Never insert any other object into the unit body to avoid any hazard or unit failure.
10. Do not put the unit close to heat-generating devices or near flammable and
dangerous materials.
11. This appliance is not intended for use by persons (including children) with reduced
physical, sensory or lack of experience and knowledge, unless they have been given
supervision or instruction concerning the use of the appliance by a person responsible
for their safety. Children should be supervised to ensure that they do not play with
the appliance.
12. If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
13. The appliance must be positioned so that the plug is accessible.
14. The appliance shall be installed in accordance with national wiring regulations.
15. The ambient temperature range for the appliance is 41℉- 95℉.
Don’t try to repair, dismantle or remold such appliance, or it may
make some damage. Even the change of power cord should be
done by specially qualified people.

2
PARAMETERS
Model No.
OL12D-D023B
Power Supply
AC115V/60Hz
Power Consumption/Current
165W/1.8A@80℉,60%RH
Power Consumption/Current
195W/2.0A@86℉,80%RH
Dehumidify Capacity
9Pints/Day@65℉,60%RH
Dehumidify Capacity
13Pints/Day@80℉,60%RH
Dehumidify Capacity
24Pints/Day @86℉,80%RH
Noise
≤36dB(A)
Full Water Quantity
2.0L
Refrigerant /Charge
R134a/3.70oz(105g)
Net Weight 10.4kg/23 lbs
FEATURES
●24Pints/Day efficient dehumidification
●Three optional modes (AUTO,CNT,SLEEP)
●Compact and modern design
●Extremely quiet operation(36dB(A))
●Auto defrosting
Body Size 10 x 8.5x 19.5 in

3
PRODUCT DESCRIPTION

4
DIGITAL DISPLAY
OPERATRIONS
Power
In the standby state, press the power button to turn on, the operation indicator
light is on and the default fan speed is high, and the default humidity is 50%. In
the power-on state, press the power button to turn off, the running indicator
light goes off and the compressor stops immediately, and then the fan shuts
down after 30 seconds’ delay.
.Modes
Auto mode - Continuously drying mode - Sleeping mode cycle, press once to
switch the mode from one to another, and the corresponding indicator lights up.
●Auto mode: When environmental humidity ≥setting humidity +3%, the fan
starts working and the compressor starts working after 3 seconds. When
environmental humidity ≤setting humidity -3%, the compressor stops
working and the fan stops working after 30 seconds’ delay.
Both fan speed and humidity can be adjusted in the auto mode.

5
●Continuously drying mode: The machine continues to run, but the humidity
can not be adjusted.
●Sleeping mode: Touch the sleep button, the button lights up and the sleep
function starts. After no operation in 10 seconds, all indicators turn dark
gradually and the wind speed is automatically switched from high to low. Touch
any button to wake up the indicator. Touch sleep button again to exit the
sleeping mode.
When environmental humidity ≤57%,
the compressor stops working and the
fan shuts down after 30 seconds’ delay.
When environmental humidity ≥63% ,the fan starts working and the
compressor starts working after 3 seconds.
Fan speed and humidity can not be adjusted in the sleeping mode.
Timer
Press the timer button to set the 0-12 hour timing function. The interval is 1
hour. Each time you press this button, the value increases by 1 hour and then
the corresponding timing value is displayed on the screen. The setting
value is “00” to cancel the timer function. The indicator turns out. After the
timer is set and completed, the timer LED is on during the timing period. After
the timing is over, the timer LED turns off automatically.
In the running state, set the time to turn off the machine;
In the standby state, set the time to turn on the machine.
Humidity Set
Touch the humidity button to check the current environmental humidity, touch
this button again and you can set the humidity. The range of target humidity is
30% - 35% - 40% - 45% - 50% - 55% - 60% - 65% - 70% - 75% - 80%. After
setting for 3 seconds, the system confirms the input value and then the
machine exits the setting state, and returns to the current humidity. In the
drying mode, the target humidity cannot be changed.
Press and hold the humidity button for 3 seconds to display the current
ambient temperature.

6
Speed
High wind - Low wind cycle, press button once to switch and then the
corresponding indicator lights up. In continuously drying mode, sleeping mode
and defrosting period, the wind speed can not be changed.
Child-lock
Press and hold the button for 3 seconds to turn on/off the child-lock function.
Accessories
1. Water Pipe 1pcs
2. Instruction manual 1pcs
Water Tank Full Alarm
Water Tank Indicator
●When the tank is full for 5 seconds, it sets the alarm. The water tank indicator
turns red and the unit buzzes for 5 times.
Clear the alarm
●When the buzz is on, press any button to stop it. The compressor and the fan
shut down and all the functions freeze until the tank is emptied and back in
right position.
Empty the tank
●Grab the notch at the bottom of the tank and pull it out with both hands.
Take it slowly and steadily in case of spilled water.

7
●Empty the water tank.
●Put the water tank back in position. The dehumidifier automatically starts
working again.
MAINTENANCE
PRECAUTIONS
If the tank is dirty, wash it with cool/warm water. Do not use any
cleanser, steel balls, chemically treated dust-proof cloth, gasoline,
benzene, thinners or other chemical solvents in case of damage and
leakage.
Continuous Drainage
●Take out the water tank
Ensure the water tank is in right
position when putting it back,
otherwise the dehumidifier can
not start up.
Do not remove the float from
the tank, otherwise the
dehumidifier can not start up.
1
2
3
4
Ce manuel convient aux modèles suivants
1
Table des matières