ROTOSOL INVERT RIS K Series Manuel utilisateur

1
On-Grid PV Inverter
Residential Inverter :RISxK-(x=1,2,3,4,5,6,8)

2
USERS MANUAL
INSTALLATION, OPERATION AND REPAIR MANUAL
About Rotosol
Rotosol solar (Division of Rotomag Motors and Controls Pvt. Ltd., located Near Anand,Gujarat,India .,
which is specialized in manufacturing of solar PV inverters.
Rotosol is dedicated to providing perfect power conversion and control solutions for solar power
generation installations , manufacturing and marketing of solar PV inverters. Rotosol possesses the first-
class production equipment . Rotosol provide all kinds of high-quality and reliable grid-connected solar
inverters and energy system solutions to satisfy the consistently increasing demands for global energy.
The newly designed PV Inverter features itself with full load high efficiency, high reliability and user-
friendly interface. The maximum conversion efficiency of our inverter is up to 98%. A user-friendly
installation & interface, professional industrial design, and design for reliability mechanism, give the
Inverter Family a competitive edge for customers from all regions.
As a customer-oriented company, Rotosol is always trying to improve product and enhance customer
satisfaction. High quality with customer satisfaction is the Goal of Rotosol , not just in product quality
control, but also in quality of service and support. Rotosol is able to help customers reduce energy
consumption and carbon dioxide emissions by leading green solutions.

3
CONTENTS
1. About This manual.......................................................................................................................................... 4
1.1Scope of Validity................................................................................................................................. 4
1.2 Target Group.........................................................................................................................................4
1.3Additional Information...................................................................................................................... 4
2Safety Instructions................................................................................................................................................ 4
2.1 Safety Precautions............................................................................................................................ 4
2.2 Explanations of Symbols.................................................................................................................. 6
3 Unpacking............................................................................................................................................................. 7
3.1 Assembly Parts................................................................................................................................. 7
3.2 Identifying the Inverter.....................................................................................................................8
4 Mounting................................................................................................................................................................ 8
4.1 Safety................................................................................................................................................8
4.2 Selecting the Appropriate Mounting Location................................................................................. 9
4.3 Mounting the Inverter with Wall Mounting Bracket...................................................................... 10
5 Electrical Connection................................................................................................................................... 11
5.1 Overview of the Connection Area.................................................................................................. 12
5.2 Connection to the Public Grid (AC)...............................................................................................14
5.3 Connection to the PV Generator (DC)................................................................................................ 17
6 Electrical Connection—RISxK(x=3-8)......................................................................................................... 23
6.1 Overview of the Connection Area.................................................................................................. 23
6.2 DC, AC& Ground connection........................................................................................................ 25
7 System Diagram..............................................................................................................................................28
8 Operation............................................................................................................................................................ 30
Product Overview..................................................................................................................................................30
8.1 Residential Series Operation................................................................................................................31
8.2 Small Commercial Series Operation.................................................................................................... 36
8.3 LCD Back light Control................................................................................................................. 42
9 Trouble Shooting............................................................................................................................................... 42
10 Inverter Inspection and Repair.............................................................................................................49
10.1 LCD cannot Display.........................................................................................................................49
10.2 LCD display Fault Codes.................................................................................................................. 49
10.3 Check list of Visual Inspection........................................................................................................... 52
10.4 Power Components Inspection(without DC power supply).................................................................. 52
10.5 MOSFET Driver Inspection(for 5th generation models).......................................................................57
10.6 Grid-connection Test.........................................................................................................................57
10.7 Inverter Frequently Tripping Due to Grid Fluctuation...........................................................................57
11 Contact..............................................................................................................................................................59
Annex Warranty Terms (Overseas)........................................................................................................... 59

4
1. About This manual
1.1 Scope of Validity
This manual describes the installation, commissioning, operation and maintenance of the following on-grid
PV inverters produced by Rotosol:
Residential Series(Single MPPT Tracking)
RIS1K RIS2K
Residential Series(Double MPPT Tracking)
RIS3K RIS4K RIS5K RIS6K RIS8K
Please keep this manual all time available in case of emergency.
1.2 Target Group
This manual is for qualified personnel. The tasks described in this manual must only be performed by
qualified personnel.
1.3 Additional Information
For more information please go through the website www.rotosol.solar
2 Safety Instructions
2.1 Safety Precautions
1. All work on the Inverter must be carried out by qualified electricians. And ensure that children can
not access to the equipment.
2. The device may only be operated with PV generators. Do not connect any other sources of energy
to the device.
3. This PV generator and inverter must be connected to the ground in order to reach maximum
protection for property and persons.
4. Do not touch cover until 3 minutes after disconnecting all sources of supply. This is because the
charge stored in capacitors may result a risk of electric shock.
5. The enclosure of Inverter can become hot during operation. To reduce the risk of injury, do not

5
touch the cover, heat sink at the back of the PP-lnverter or nearby surfaces while Inverter is
operating.
6. Do not use the equipment for purposes other than those described in this manual.
7. Both the Inverter and associated transport packaging are mainly made of recyclable raw materials.
Please ensure that the used device and any relevant accessories are disposed of in accordance
with applicable regulations.
8. Packed with damping EPE and carton, Rotosol inverter should be placed upwards and handled
with care in delivery. Pay attention to waterproof.
9. Alternative uses, modifications to the inverter not recommended by Rotosol or the installation of
components not sold by Rotosol void the warranty claims.

6
2.2 Explanations of Symbols

7
3 Unpacking
3.1 Assembly Parts
Please check the delivery for completeness and any visible external damage. Contact your dealer at once
if anything is damaged or missing.
RISxK(x=1,2,3,4,5,6,8) assembly parts are as listed below:
Applies to RISxK (x=3,4,5,6,8)
1set applies to RISxK (x=1,2)
2 sets applies to RISxK (x=3,4,5,6,8)

8
3.2 Identifying the Inverter
You can identify the Inverter by the type label. Information such as serial number (Serial No.) and
model name of the Inverter, as well as the device's technical parameters are specified on the type
label. The type label is on the right side of the enclosure.
4 Mounting
4.1 Safety
DANGER!
Danger to life due to potential fire or electric shock.
Do not install the Inverter near any inflammable or explosive items. The inverter will be directly connected
with high voltage power generation device. The installation must be performed by qualified personnel only
in compliance with national or local standards and regulations.
CAUTION!
Danger of burn injuries due to hot enclosure parts.
•Install the Inverter so that it cannot be touched inadvertently. Risk of injury due to the heavy weight
of the Inverter.
• Take the inverter's weight into account for mounting. (Weight of inverter refers to chapter 9.)

9
4.2 Selecting the Appropriate Mounting Location
Consider the following points when selecting where to install:
The mounting method and location must be suitable for the inverter's weight and dimensions.
The inverter must be installed in the solid walls ,such as brick walls or concrete walls in case of
vibration noise or inverter falling off.
The installation site should be clearly visible and can be safely into without aids such as scaffold.
For the convenience of checking the LCD display and possible maintenance activities, please
install the inverter at eye level.
The altitude of installation site should be below 2000m,more than 2000m above the sea level will
cause derating.
The ambient temperature of installation site should be between -20 °C and +55 °C (between -4 °F
and 131 °F).
Install the inverter directly exposing to strong sunshine is not recommended, the excess heating
might lead to power reduction.
Leave enough effective space around the inverter for better ventilation.
• Vertical installation, wiring area must be downside, lateral installation is not allowed; in backward
tilted installation, tilt angle should not exceed 30 degrees; Forward tilted, horizontal or inverted
installation is not allowed.

10
4.3 Mounting the Inverter with Wall Mounting Bracket
1. Use the wall mounting bracket mark the drilling position and drill the holes for the screws.
3. Hang the inverter to the mounting bracket and ensure the slot is fitted on the bracket.