Roda RS-FS60AB Manuel utilisateur

AIRCONDITIONER
FLOOR STANDING TYPE
SERVICE MANUAL
RS-FS60AB/RU-60AC3

CONTENTS
1. Safety Precautions ............................................................................................................. 1
1.1 Precaution ............................................................................................................................ 1
1.2 Installation ............................................................................................................................ 1
1.3 Caution ................................................................................................................... ............. 1
1.4 Operational ............................................................................................................... ........... 2
2. Dimension .................................................................................................................. ........ 3
2.1 Indoor Unit ............................................................................................................................ 3
2.2 Outdoor Unit ............................................................................................................ ............. 4
3. Refrigerant cycle diagram ................................................................................................. 4
3.1 Heat pump mode .................................................................................................................. 4
4. Wiring diagram ............................................................................................................. ...... 5
4.1 RS-FS60AB ......................................................................................................................................... 5
5. Installation details .............................................................................................................. 6
5.1 Installation place ...................................................................................................... ............ 6
5.2 Installing .............................................................................................................. ................. 8
5.3 Refrigerant pipe connection ............................................................................................. .. 10
5.4 Drain Pipe of The Indoor Unit ........................................................................................... .. 21
5.5 Wiring .................................................................................................................. ............... 22
5.6 TEST RUN ................................................................................................................. .......... 22
6. External view and display ............................................................................................... 23
6.1 PARTS NAMES ............................................................................................................. ..... 23
6.2 CONT ROL PANEL ........................................................................................................... .. 24
6.3 LED ..................................................................................................................... ............... 25
7. Operation characteristics ................................................................................................ 26
8. Electronic function ........................................................................................................ .. 26
8.1 Main data Introduction .................................................................................................... ... 26

8.2 Operation Modes and Functions ........................................................................................ 26
8.3 Other Functions ........................................................................................................... ...... 29
9. Characteristic of temperature sensor ............................................................................ 30
10. Trouble shooting .......................................................................................................... .... 30
10.1 Protective Function ............................................................................................................. 30
10.2 Self-diagnosis .................................................................................................................... 32
10.3 LEDs for the indication of outdoor trouble .......................................................................... 32
10.4 Troubles and Solutions ...................................................................................................... 33

1
1. Safety Precautions
1.1 Precaution
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage.
Before service unit, be sure to read this service manual at first.
1.2 Installation
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized service
center.
Do not disassemble or repair the product by yourself.
Sharp edges could cause injury, be especially careful of the case edges and the fins on the
condenser and evaporator.
Be sure the installation area does not deteriorate with age.
Take care to ensure that power cable could not be pulled out or damaged during operation.
Do not place anything on the power cable.
Do not plug or unplug the power supply plug during operation.
Do not store or use flammable gas or combustible near the product.
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the
product on.
If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the
power supply cable as soon as possible.
When the product is soaked (flooded or submerged), contact an Authorized service center.
Be caution that water could not enter the product.
Turn the main power off when cleaning or maintaining the product.
When the product is not be used for a long time, disconnect the power supply plug or turn off the
breaker.
1.3 Caution
Always check for gas (refrigerant) leakage after installation or repair of product.
Install the drain hose to ensure that water is drained away properly.
Keep level even when installing the product.
Do not install the product where the noise or hot air from the outdoor unit could damage the
neighborhoods.
Use two or more people to lift and transport the product.
Do not install the product where it will be exposed to sea wind (salt spray) directly.

2
1.4 Operational
Do not expose the skin directly to cool air for long periods of time. (Do not sit in the draft).
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a
consumer air conditioner, not a precision refrigerant system.
Do not block the inlet or outlet of air flow.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
Do not touch the metal parts of the product when removing the air filter. They are very sharp.
Do not step on pr put anything on the product. (outdoor units)
Always insert the filter securely. Clean the filter every two weeks or more often if necessary.
Do not insert hands or other object through air inlet or outlet while the product is operated.
Do not drink the water drained from the product.
Use a firm stool or ladder when cleaning or maintaining the product.

3
2. Dimension
2.1 Indoor Unit
Dimension
Mode
W
(mm)
D
(mm)
H
(mm)
55K 600 358 1900

4
2.2 Outdoor Unit
Dimension
Mode
W
(mm)
D
(mm)
H
(mm)
W1
(mm)
A
(mm)
B
(mm)
55K 940 360 1245 1020 602 380
3. Refrigerant cycle diagram
3.1 Heat pump mode

5
4. Wiring diagram
4.1 RS-FS60AB
Indoor Unit
Outdoor Unit

6
5. Installation details
5.1 Installation place
5.1.1 Indoor Unit
a.Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
b.There should not be any heat source or steam near the unit.
c.There should not be any obstacles blocking the air circulation.
d.A place where air circulation in the room is good.
e.A place where drainage can be easily done.
f.Do not install the unit near the door way.
g.There should not be any direct sunlight. Otherwise, the sun will fade the plastic
cabinet and affect its appearance. If unavoidable, sunlight prevention should be taken into
consideration.
5.1.1.1 Please stand the unit in hard and flat ground;
Please reserve space for installation and maintenance.
5.1.1.2 Please check the elevation difference between the indoor unit and the outdoor
unit, the length of the refrigerant pipe, and the curved places (bend) of the pipe are no
more than the following numbers:
Elevation difference: no more than 15 M (if the elevation difference between indoor
and outdoor unit is more than 15 meters, it is recommended
that the indoor unit be located higher than the outdoor unit.)
Pipe length: no more than 30M
Bends: no more than 3 places.
5.1.2 Outdoor Unit
The outdoor unit should be put in a position that guarantees the minimum space for
sufficient air circulation and to allow maintenance work and the connections of electrical
and refrigerant circuit lines. It may be installed on a floor or flat roof or wall-mounted,
provided its weight isproperly supported and there is no transmission of vibration to the
adjacent rooms.
5.1.2.1 Before installing the outdoor unit, you should:
a).If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat
radiation from the condenser is not obstructed.

7
b).Select a place that is easy to connect indoor unit's pipe and electric wires.
c).Avoid a place where combustible gas may leak or stay.
d).Keep it in mind that water may drain out of the outdoor unit while in "Heat" mode.
e).Ensure the space around the back and sides and the front of the unit.
f).Take the air conditioner weight into account and select a place where noise and
vibration are minimum.
5.1.2.2 If the outdoor unit is to be installed on a roof or where no constructions are around,
you should avoid hard wind blows directly to the air outlet, because it may
cause trouble for air-flow shortage.
5.1.2.3 Reserve enough space for installation, maintenance and unit-functioning.
Remove as many obstacles as possible nearby.
Caution:
Installation in the following places may cause trouble. If it is unavoidable to use in such
places,please consult with the dealer.
(1) A place full of machine oil.
(2) A saline place such as coast.
(3) Hot-spring resort.
(4) A place full of sulfide gas.
(5) A place where there are high frequency machines such as wireless installation,
welding machine, medical facility.
(6) A place of special environmental conditions.
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Roda Climatiseur