Robern VESPER EDGELINE LIGHTS Manuel utilisateur

Part no. 209-1330 01/06/21
Vesper Edgeline Lights
1
© 2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376 www.robern.com
TOOLS NEEDED / PARTS - 3
ASSEMBLING THE BRACKETS - 5
MOUNTING THE BRACKETS TO THE CABINET - 6
MOUNTING THE BRACKETS BETWEEN CABINETS - 7
ACCESS THE ELECTRICAL ENCLOSURE - 8
RECESSED INSTALLATION - 9
SURFACE INSTALLATION - 11
FINAL ASSEMBLY - 14
PRODUCT ALIGNMENT - 16
This instruction sheet contains information on how to install the Vesper Edgeline Lights. This series comes in many variations. Please
refer to the box or product label for the specic model number. A key is provided on page 2.
Save these instructions for future use and reference. An improper installation voids the warranty. Carefully inspect the lights for
damage. Installed products cannot be returned.
If you experience any problems with your lights, contact your dealer or Robern directly.
Limited Warranty — One Year Term
VESPER™EDGELINE LIGHTS
Installation Instructions
Important safety instructions - Save these instructions
Suitable for damp locations
CONTENTS
GENERAL INFORMATION

Part no. 209-1330 01/06/21
Vesper Edgeline Lights
2
© 2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376 www.robern.com
For dimmable models Robern recommends the Maestro® C•L® Dimmer from LUTRON®, Model # MACL-153M.
http://www.lutron.com/TechnicalDocumentLibrary/369613a.pdf
Other LED control dimmers may operate with this product but have not been tested or veried. It's recommended that the dimmer be
within reach of your mirror so you can adjust the brightness.
For on/off (non-dimming) operation a standard wall switch may be substituted in place of the dimmer.
DIMMER RECOMMENDATIONS
Model Numbers G L A 40 E L P S 3D
Product Line G = Vesper
L = Lights
A = 1-3/8" / 35 mm
30 = 30" / 762 mm
36 = 36" / 914 mm
40 = 39-3/8" / 1000 mm
E = Edgeline
L = LED
3 = 3000K
P = Pair Lamp
D = Dimmable
S = Silver
Light Name
Width
Quantity of Lamps
Engine Type
Category
Type of Lamp
Color Temperature
Height
Main Body Color
Use the chart below to learn how to read your light model number. This chart references the model number for 1-3/8" W x 40" H Vesper
Edgeline Lights with a silver metal nish. Consult the Robern Price Book for a complete list of model numbers.
MODEL NUMBERS

Part no. 209-1330 01/06/21
Vesper Edgeline Lights
3
© 2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376 www.robern.com
TOOLS NEEDED
[SS676]
(8) Screw, #10 x 1/2"
[SS344]
(3) Screw, #8 x 3/8"
[210-1661]
(4) Mounting Brackets
(2) Edgeline Lights
[205-3214]
(1) Electrical Enclosure
PARTS
Hardware Bag*
[216-1232]
[203-1068]
(3) #8 Lockwasher
* Depending on installation, not all parts will be used
[203-1057]
(1) 3/32" Allen Key
[219-1076]
(1) Cable Tie Holder
[203-1089]
(1) Cable Tie, 4"
[SS675]
(4) Screw, #10 x 3"
[205-3304]
(4) Adjustable
Button Receiver
[SS672]
(12) #10 Screw Cap
[203-1497]
(2) Screw, #8 x 3/8" Flat
[211-1351]
(2) Mounting Button
[203-1538]
(10) Screw, #8 x 5/8" Flat
Bag D*
[216-1230]
(2) Bag A*
[216-1227]
Bag B*
[216-1228]
(2) Bag C*
[216-1229]

Part no. 209-1330 01/06/21
Vesper Edgeline Lights
4
© 2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376 www.robern.com
Unpack the Lights. Check the box thoroughly for all hardware and loose parts. Carefully inspect the xture for damage.
DANGER: Risk of personal injury. To avoid possible electrical shock, the electricity must be turned off at the circuit
breaker or fuse box before attempting any installation procedure.
DANGER: Risk of personal injury. To avoid possible electrical shock, the light xture must be properly grounded.
CAUTION: Grounding instructions for permanently connected products: This product must be connected to a grounded,
metal permanent wiring system or an equipment-grounding conductor must be run with the circuit conductors and connected to the
equipment-grounding terminal or lead on the product. All wiring should be done by a qualied licensed electrician.
IMPORTANT: Power for the lights should be provided separately from the electricity to the cabinet so that when lights are turned off,
cabinet electricity remains on.
NOTE: Requires minimum 120 VAC 15 amp circuit.
NOTE: Requires an approved compatible dimmer for installation (not included). Refer to the dimmer recommendation on page 2.
Observe all applicable electrical codes and building codes. Wire the light xtures in accordance with the electrical codes.
This xture is for indoor use only.
This installation may require the assistance of more than one person depending on your Light/Cabinet conguration.
NOTES
DANGER - RISK OF SHOCK -
DISCONNECT POWER BEFORE INSTALLATION

Part no. 209-1330 01/06/21
Vesper Edgeline Lights
5
© 2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376 www.robern.com
ASSEMBLING THE BRACKETS
Note: A RH (Right Hand) installation will require the electrical enclosure to be ipped, placing the exiting low voltage wire
closer to the upper bracket.
Note: For 1.375 pair installations involving more than one cabinet, a RH installation is required.
1. Orient one of the mounting brackets [210-1661] (as shown) ensuring that the electrical access screws on the electrical enclosure
[205-3214] are pointed toward the front of the cabinet.
2. Attach the included electrical enclosure [205-3214] to the bracket using the supplied #8 screws [SS344] and lockwashers [203-1068].
SS344 SS344
203-1068 203-1068
210-1661
205-3214
205-3214
Electrical
access screws
Low voltage
wire connection
Tabs always face
cabinet box
LH Installation RH Installation
Tabs always face
cabinet box
210-1661
Electrical
access screws
Electrical
access screws
Electrical
access screws
Low voltage wire
connection

Part no. 209-1330 01/06/21
Vesper Edgeline Lights
6
© 2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376 www.robern.com
MOUNTING THE BRACKETS TO THE CABINET
Note: When mounting the lights between cabinets, see the following page.
1. Mount the brackets to the cabinet through the ganging locations, as shown, using the supplied #10 screws [SS676].
SS676
SS676

Part no. 209-1330 01/06/21
Vesper Edgeline Lights
7
© 2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376 www.robern.com
Note: A Ganging Kit (refer to the cabinet's instructions, sold separately) is required for the following instructions. All additional
components shown in the following steps will be included with the Ganging Kit. Enough components are included to gang two lights
between cabinets.
1. Using two #8 x 3/8" screws [SS344] and two lockwashers [203-1068], attach the mounting brackets to the Electrical Enclosure.
2. Using two #10 x 1/2" screws [SS676], attach each mounting bracket to a ganging block, included in the Ganging Kit.
3. Attach the mounting bracket assemblies to each cabinet with four #10 x 1/2" screws [SS676].
MOUNTING THE BRACKETS BETWEEN CABINETS
1 2
3
[203-1068]
(2) #8 Lockwasher
[SS344]
(2) Screw, #8 x 3/8"
[SS676]
(4) Screw, #10 x 1/2"

Part no. 209-1330 01/06/21
Vesper Edgeline Lights
8
© 2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376 www.robern.com
ACCESS THE ELECTRICAL ENCLOSURE
Lay the cabinet on a at level surface.
1. Remove the electrical enclosure cover to access the electrical wiring connections. Set the cover aside in a safe place.
* Make proper connections
according to the dimmer
manufacturer's instructions
CIRCUIT BREAKER
120VAC
15A
DIMMER*
FIELD CONNECTION
ELECTRICAL ENCLOSURE
LINE/BLACK
NEUTRAL/WHITE
GROUND
BLACK
WHITE
GROUND
1

Part no. 209-1330 01/06/21
Vesper Edgeline Lights
9
© 2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376 www.robern.com
RECESSED INSTALLATION
When connecting the Electrical Enclosure to the remote light, it is recommended to route the wiring so that it does not get
pinched during recessed mounting.
1. Centered on the cabinet side opposite the electrical enclosure, attach the wire control mount [219-1076] to the cabinet side by
peeling and sticking it in place.
2. Route the wire around the back the cabinet until it reaches the wire control mount.
3. There will be an excess of length (wire will accomodate two ganged 24" cabinets). Coil the excess wire and secure in place with the
provided zip tie [203-1089].
Back View

Part no. 209-1330 01/06/21
Vesper Edgeline Lights
10
© 2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376 www.robern.com
RECESSED INSTALLATION
4. With the electrical cover removed, support the cabinet on the edge of the recessed opening and feed the eld wire through the eld
wire strain relief at the back of each enclosure.
5. Push the cabinet assembly into the recessed opening until the back of the cabinet ange is tight to the nished wall surface.
6. Using a level, level and plumb the products in the opening. Shim as necessary. Using a square, make sure the cabinet is square in
all axis.
7. Make the electrical connection according to the electrical diagram on page 8.
Note: Refer to your cabinet's Instructions to insure there are no additional steps required prior to proceeding.
8. Mount the cabinet in place using the #10 Screws [SS674] provided with the cabinet.
RO Width =
Width of cabinet +
width of lights - 3/4" (19 mm)
RO Height =
Height of cabinet - 3/4" (19 mm)
Table des matières
Manuels Équipement d'éclairage populaires d'autres marques

Qazqa
Qazqa Suplux SL 3 Black 103062 Manuel utilisateur

Commercial Electric
Commercial Electric 54568141 Manuel utilisateur

CREE LIGHTING
CREE LIGHTING 304 Series Manuel utilisateur

Goobay
Goobay 49867 Manuel utilisateur

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Manuel utilisateur

Alkalite
Alkalite Krypton KT-81 Manuel utilisateur