Contents
Introduction 1
Setting the System 2
Part Setting the System 2
Unsetting the System 3
Resetting after an Alarm 3
User Programming Mode 3
Removing Individual Zones 5
Testing the System 7
Reading the Log 8
Turning Chime On and Off 9
Programming User Codes 11
Care and Service of Your System 13
Terminology 13
Installers Details 14
Service Record 14
GARDTEC 350 Users Manual
350 USER - inst quark.QXD 12/10/02 20:12 Page 1

GARDTEC 350 USER INSTRUCTIONS
INTRODUCTION
Your Gardtec 350 Control Panel will have been fully programmed by your installation
engineer to suit your needs. Normal day to day operations will consist of the following:-
Fully setting the system
Part setting the system
Unsetting the system
Display is given via eight individual L.E.Ds. When using the Gardtec 350 in it’s normal
user mode the bold black legend is used, this is shown in Fig 1. below.
Fig 1.
A key press tamper will activate if more than 24 invalid digits are entered. This
will cause an internal alarm if the unit is unset and a full alarm if the unit is set.
Keys 1 and 3 have been factory programmed for P.A (Personal Attack). This is a 24
hour function and will operate if the control panel is set or unset. To use the keypad
P.A function press and hold keys 1 and 3 at the same time, the alarm will then activate.
To stop the alarm sounding enter a valid user code. After the keypad P.A function has
been used the system will require resetting as shown on page 3.
GARDTEC 350 Users Manual
300 Series
GARDTEC
POWER
DAY
Z1
Z2
Z3
Z4
Z5
TAMPER
REMOVE
TEST
LOG
CHIME
PROGRAM
ENTER
Page 1
350 USER - inst quark.QXD 12/10/02 20:12 Page 2

SETTING THE SYSTEM
To Fully Set the system proceed as follows:-
1) Enter a valid User code. (The DAY LED will flash followed by the exit tone.
Any zones violated during exit will change the
exit tone and the appropriate L.E.D will indicate).
2) Leave the premises via the
authorised exit route.
Note: To abort setting during exit time re-enter the code.
PART SETTING THE SYSTEM
To Part Set the system proceed as follows:-
1) Enter a valid User code. (The DAY LED will flash followed by the
exit tone).
2) If Part Set 1 is required Press 1 or (The DAY LED will flash slowly. Zones
programmed as Part 1 will be removed)
If Part Set 2 is required Press 2 or (The DAY LED will flash slowly. Zones
programmed as Part 2 will be removed)
If Part Set 3 is required Press 3 (The DAY LED will flash slowly. Zones
programmed as Part 1 and Part 2 will
be removed).
3) Leave the premises via the authorised exit route (or retire to an unprotected
area).
Note: If any of the above part sets have been programmed as silent by your
engineer the setting will be silent with a single beep as the system final-
ly sets.
Page 2
GARDTEC 350 Users Manual
350 USER - inst quark.QXD 12/10/02 20:12 Page 3

UNSETTING THE SYSTEM
To Unset the system proceed as follows:-
1) Enter the premises via an authorised entry point (the entry tone will sound).
2) Proceed directly to the Control Panel and enter a valid User code (the entry
tone will stop and the DAY LED will illuminate).
3) If the alarm has been activated during the set period all the LEDs will flash
press NO to view the cause of alarm.
RESETTING AFTER AN ALARM
If the system is set, unset it as shown above and proceed as follows:-
1) After an alarm all the LEDs will be flashing. If you wish to view the cause of
alarm press NO. To Reset the system enter the Master code and start to set
the system.
2) Before the entry time expires enter a valid code to abort the setting. The
system is now reset.
USER PROGRAMMING MODE
To enhance the flexibility of the Gardtec 350 Control Panel there are five user pro-
grammable options available. When programming the User options the display is via
the five Zone L.E.Ds and the White legend is used. This is shown in Fig 2. below. It
should be noted the the user programming mode is only available to the Master user
(User 1).
Fig 2.
Page 3
GARDTEC 350 Users Manual
300 Series
GARDTEC
POWER
DAY
Z1
Z2
Z3
Z4
Z5
TAMPER
REMOVE
TEST
LOG
CHIME
PROGRAM
ENTER
350 USER - inst quark.QXD 12/10/02 20:12 Page 4

The User programmable options are as follows:-
RReemmoovvee
This option enables the Master user to Remove individual zones when setting the sys-
tem. This is in addition to any part set suites pre-programmed by your engineer.
TTeesstt
This option allows the Master user to Test the system.
LLoogg
This option allows the Master user to view the event Log.
CChhiimmee
This option allows the Master user to turn the Chime option On and Off. (The zones
that are on chime will have been programmed by the installation engineer).
PPrrooggrraamm((CCooddee))
This option allows the Master user to change the Codes for the Master user (User1),
User (User2) and Set only user (User3) levels.
When programming the User options the LEDs may show the following status:-
Fig 3.
To program the options shown above proceed as follows:-
Page 4
GARDTEC 350 Users Manual
OFF
ON
FLASHING
350 USER - inst quark.QXD 12/10/02 20:12 Page 5

REMOVING INDIVIDUAL ZONES
1) With the Control panel in the DAY mode (Unset) enter the Master code. The
exit tone will sound.
2) Before the exit time expires Press NO. The exit tone will silence and the
RReemmoovveeLED will flash as shown in Fig 4.
Fig 4.
3) Press YES to program the RReemmoovveeoption. The display will show as Fig 5.
Fig 5.
Page 5
GARDTEC 350 Users Manual
300 Series
GARDTEC
POWER
DAY
Z1
Z2
Z3
Z4
Z5
TAMPER
REMOVE
TEST
LOG
CHIME
PROGRAM
ENTER
300 Series
GARDTEC
POWER
DAY
Z1
Z2
Z3
Z4
Z5
TAMPER
REMOVE
TEST
LOG
CHIME
PROGRAM
ENTER
350 USER - inst quark.QXD 12/10/02 20:12 Page 6

Page 6
GARDTEC 350 Users Manual
4) Press the key corresponding to the zone you wish to remove followed by the
YES key (a comfort tone will be generated if all is okay). If you make a mis-
take and remove the wrong zone repeat the operation from step 3 but press
NO after the zone number.
5) If you wish to remove more zones repeat from step 3.
6) When you have finished removing the required zone(s) press the 0 key to
escape programming mode.
Note: This operation should be carried out each time you wish to remove
individual zones. If you remove the same zone(s) on a regular basis ask
your engineer to put them in a part set suite.
350 USER - inst quark.QXD 12/10/02 20:12 Page 7

TESTING THE SYSTEM
1) With the Control panel in the DAY mode (Unset) enter the Master code. The
exit tone will sound.
2) Before the exit time expires Press NO. The exit tone will silence and the
RReemmoovveeLED will flash.
3) Press NO and the TTeessttLED will flash as shown in Fig 6.
Fig 6.
4) Press YES to select the TTeessttoption and the flashing TTeessttLED will illumi-
nate steadily.
5) You may now "walk test" the system. Any zones that are violated will
generate a tone and the appropriate LED will flash. If you wish to test the
external sounders and strobe pressing 9 will toggle the external sounders
and strobe On and Off.
6) To escape from the TTeessttoption press 0 and the display will show as in Fig 6.
7) If you wish to return to DAY mode Press 0 again.
Page 7
GARDTEC 350 Users Manual
300 Series
GARDTEC
POWER
DAY
Z1
Z2
Z3
Z4
Z5
TAMPER
REMOVE
TEST
LOG
CHIME
PROGRAM
ENTER
350 USER - inst quark.QXD 12/10/02 20:12 Page 8
This manual is found at www.eaglesecuritysolutions.co.uk

LOG
The Gardtec 350 has a 50 event Log that records system events in the order that they
occur. To view the Log proceed as follows:-
1) With the Control panel in the DAY mode (Unset) enter the Master code. The
exit tone will sound.
2) Before the exit time expires Press NO. The exit tone will silence and the
RReemmoovveeLED will flash.
3) Press NO Twice and the LLooggLED will flash as shown in Fig 7.
Fig 7.
4) Press YES to use the LLooggoption. The display shown is the last event. To
view the previous event press NO, to move to the next event press YES.
5) To escape out of the LLooggoption press 0 and the display will show as in Fig 7.
6) If you wish to return to DAY mode press 0 again.
Whilst in the LLooggmode the LEDs may display the following:-
All LEDs on indicates an alarm, press NO to view the cause.
DAY LED with Z1, Z2 or Z3 LEDs indicate unset by user 1, 2 or 3
Rapid flashing DAY LED. System was Set. Slow flashing DAY LED System was Part
set
If all the LEDs are flashing this indicates an alarm occurred. Pressing NO to move to
the previous event will show the cause of alarm
If the zone LED(s) are illuminated without the alarm indication the zone was removed.
Page 8
GARDTEC 350 Users Manual
300 Series
GARDTEC
POWER
DAY
Z1
Z2
Z3
Z4
Z5
TAMPER
REMOVE
TEST
LOG
CHIME
PROGRAM
ENTER
350 USER - inst quark.QXD 12/10/02 20:12 Page 9
Autres manuels pour GardTec 350+
1
Table des matières
Autres manuels Risco Panneau de contrôle

Risco
Risco RisControl Manuel utilisateur

Risco
Risco LightSYS Manuel d'instructions

Risco
Risco GT 600 Manuel utilisateur

Risco
Risco ProSYS 128 Manuel utilisateur

Risco
Risco GardTec 350+ Manuel utilisateur

Risco
Risco Gardtec GT480 Manuel utilisateur

Risco
Risco RisControl Manuel utilisateur

Risco
Risco GT 601 Manuel d'instructions

Risco
Risco GT Plus Manuel d'instructions

Risco
Risco GT 600 Manuel de programmation