Evolve 952/1253 Installation Guide: 13115-F 06-22 | 5
Specication
Specication summary
952 1253
Input LPG MJ/h 10-32 17-32
Input NG MJ/h 10-34 17-34
Output MJ/h* 2.4-8.1 4.0-8.4
86 88
Heating area m2** 65-129 78-134
Gas type NG or ULPG
** Will vary depending on geographical location in NZ
Suitability
Ideal for living rooms and open plan areas.
installation in almost any living space, including
bedrooms.
The Evolve is ideal for a new build installation
into a false (mock) chimney.
Installation considerations
Room size—smaller rooms will heat up quickly,
set temperature has been reached.
possible. If the unit is installed higher up the
wall the movement of air from the convection
could create draughts.
Burn media
Choice of river stones or silky oak log set.
Convection fan
3-speed fan. Heat is distributed from the top of
the appliance.
Data plate
Located inside the appliance, upper right hand
side.
Gas connection
½ “ BSP, the gas supply terminates inside the
heater—lower left hand side of the appliance.
Ignition
Continuous spark electronic ignition.
Injector sizes (mm)
952 1253
NG front 2.1 2.8
rear 1.9 N/A
ULPG front 1.3 1.8
rear 1.1 N/A
Noise level - 37-45 dB(A)
Power ue
Inner 50 mm, outer 70~80 mm. Appliance must
Power consumption/electrical supply
High = 90 W
Standby = <8 W
This heater has a 1.5 m power cord with a
three pin plug supplied. The power cord passes
through a slot in the back left hand corner of
the appliance.
Safety devices
Flame failure sensing system, pressure relief,
overheat safety switch, air temperature sensor,
thermal fuse, overcurrent fuse, and spark
detector.
Temperature control
Operated by using the basic infra-red remote*,
or for more features, such as timers and
thermostatic control, using Rinnai’s Wi-Fi
* Temp. sensor is located in the bottom of the remote
Weights
• Evolve 952: 75 kg
• Evolve 1253: 100 kg
burn media options are available.