ring POWERSOURCEPURE RINVP600 Manuel utilisateur

www.ringautomotive.co.uk
24v12v12v6v
INSTRUCTIONS
Retain these instructions for future reference
POWERSOURCEPURE
Pure Sine Wave Inverter
12V: RINVP600/RINVP1000/RINVP2000/RINVP3000
24V: RINVP1024/RINVP2024
12V: RINVPR1000/RINVPR2000
24V: RINVPR1024/RINVPR2024
RCD Models
8pp A5 (PSW) UK Full Handbook v4.indd 1 07/04/2014 09:48

OVERVIEW
The Ring Pure Sine Wave (PSW) inverter provides a 230 volt supply which closely replicates the domestic
mains supply. This makes it ideal for powering more sensitive equipment which may not be compatible with
traditional Modified Sine Wave (MSW) inverters.
2
1. CONTENTS
2. FEATURES
1. Mains 230V AC outlet(s)
2. Power on/off switch
3. Power indicator
4. Over load indicator
5. Over temperature indicator
6. Remote control socket*
7. USB Port*
8. Battery positive (+)
connection
9. Battery negative (-)
connection
10. Earth connection
11. Cooling fan(s)
12. Hard wired 230V AC outlets
13. Test button for integral RCD
* - Only fitted on certain
models
Modified Sine Wave (MSW) Pure Sine Wave (PSW)
Standard Features
Additional features (RCD Models only)
1
1
2
6
7
8
89
34511
10
12
13
11
3. Battery Clamps
4. Protective Covers2. Connecting Cables
5. 3 x Cable Glands
(RCD models only)
1. Inverter
8pp A5 (PSW) UK Full Handbook v4.indd 2 07/04/2014 09:48

3
3. SAFETY
This manual contains important information about the operation of this product. Failure to comply with the
instructions can cause electric shock, fire or serious injury. Responsibility will not be accepted for damage to
persons or property caused by failure to follow the operating instructions.
- Installation should be carried out by a qualified electrician
- Do not expose the unit to moisture or flammable materials
- Do not remove the unit cover, dangerous voltages are present
4. INSTALLATION
Location
This inverter is for indoor use only and should be installed in a well ventilated, cool, dry environment.
- To prevent overheating, do not install where ventilation openings may be obstructed
- Allow 10cm all around the inverter casing to ensure adequate ventilation
- Do not install near fuel tanks or within battery compartments
Battery Connections
Connect the inverter to the battery using the supplied battery cables and terminals.
1. Ensure that the inverter power on/off switch is in the OFF (O) position.
2. To protect inverter terminals against short circuit, protective covers are provided. Note:- for rubber
versions these should be slid onto the cables prior to fixing to rear of inverter
3. Attach the black (-) cable to the black (-) terminal on the rear face of the inverter and to the black (-)
terminal on the battery
4. Attach the red (+) cable to the red (+) terminal on the rear face of the inverter and to the red (+)
terminal on the battery
5. To further protect against short circuit, it is recommended an in-line fuse (F1) be fitted near the positive
battery post.
Caution
There may be sparks produced when making battery connections, ensure no flammable materials are present.
Incorrect connection of cables to the battery (reverse polarity) may damage the unit and is not covered
by the warranty.
Single Battery System
Fig1 – Example single battery system
8pp A5 (PSW) UK Full Handbook v4.indd 3 07/04/2014 09:48

4
Dual Battery System
For heavy duty applications a secondary battery can be fitted to increase the inverter running time. An
additional relay may also be fitted to allow this battery to be charged from the vehicle alternator when the
vehicle engine is running, Fig2 shows an example installation.
Fig2 – Example dual battery system
Earth Connection
Ensure the inverter is earthed by connecting a cable from the inverter earthing bolt (10) to a suitable earth
within the installation (normally the vehicle chassis)
Caution
Do not operate the inverter without connecting it to ground, otherwise a fault condition may present
an electric shock hazard.
Earth Leakage Protection
When the inverter is used to power 230V socket outlets, which are a permanent part of the installation, a
Residual Current Device (RCD) should be fitted to provide protection in the event of a fault.
8pp A5 (PSW) UK Full Handbook v4.indd 4 07/04/2014 09:48

5
Fig3 – Integral RCD example
Fig5 – External RCD example
Fig4 – AC terminals Fig5 – Gland fitment
Caution
It is recommended the inverter is wired and tested by a qualified electrician
AC Output Connections - Models with integral RCD
To make installation simpler and provide a more integrated solution, some models are provided with internal
RCD protection and screw terminal connections. Fig3 below shows an example installation
AC Output Connections - models without integral RCD
An RCD device can still be used on models without this feature integrated into the inverter. The diagram
below shows recommended wiring for 230V sockets with an integral RCD. Note:- In order for an RCD device
to trip effectively when used in a vehicle, the neutral output from the inverter should be linked to the
earthing system of the installation. Fig5 below shows a recommended installation
1. Remove 4 x screws from cover plate to allow access to terminals
2. Knockout the required number of apertures and fit supplied cable glands
Outer glands are suitable for up to 2.5mm23-core cable
Central gland is suitable for up to 1.5mm23-core cable
3. Pass cables through gland assemblies then attach to 230V output terminals (see Fig4)
Live(L) = Brown, Neutral(N) = Blue, Earth( ) = Green/Yellow
Note:- It is recommended the supplied fork terminals are used for a more secure connection
4. Re-fit cover plate, fully tighten glands and check cables cannot move (see Fig5)
Inverter
Battery
Inverter
+
+
–
–
Vehicle
Chassis Example outputs
Output 1
Output 2
Output 3
230V AC
F1
Inverter
Battery
Inverter
+
+
–
–
Vehicle
Chassis
Appliance230V Socket with integral RCD
Fit N-E link to ensure
RCD will trip
L
N
E
L
NLOAD
E
F1
Earth
230V AC
Output1
{
{
{
LIVE
LIVE
LIVE
NEUTRAL
NEUTRAL
NEUTRAL
230V AC
Output2 230V AC
Output3
L1 L3N1 N2 N3L2
8pp A5 (PSW) UK Full Handbook v4.indd 5 07/04/2014 09:48

6
Remote Control Panel (Optional)
When the inverters on/off switch will not be easily accessible, an optional remote control panel can be fitted.
1. Recess mount the control panel and fix with 2 x screws
2. Connect data plug to socket (7) on inverter
3. Ensure inverter on/off switch is set to ON(I) position
4. Set remote control panel switch to ON (I) position
5. The power indicator will illuminate green to show the inverter is operating
1. Power on/off switch
2. Power indicator
3. Over load indicator
4. Over temperature indicator
5. Data cable & plug
5. GENERAL INFORMATION
Continuous and Surge Power
A Continuous rating is the amount of power the inverter can handle for a number of hours without
overloading. The Surge rating is a brief burst of power the inverter can provide to help start certain types of
load.
Loads requiring surge power
The power rating shown on most electrical appliances is a continuous rating but some appliances require
up to five times this power for a brief period in order to start operating. This needs to be considered when
rating the inverter to avoid overloading it.
When using a microwave oven it should also be noted that the electrical power required from the supply is
around 50% higher than the actual cooking power of the microwave.
Typical surge ratings
Typical Typical Surge
Example Appliance Rated Power Power Required (<1 sec)
Electric Drill 500W 1000W
800W Microwave Oven 1200W 2400W
Angle Grinder 900W 2700W
Portable Air Compressor 200W 700W
Laser Printer 500W 2500W
5
4
3
21
8pp A5 (PSW) UK Full Handbook v4.indd 6 07/04/2014 09:48

7
6. OPERATION
Switching on
1. Ensure that the inverter power on/off switch is in the OFF (0) position.
2. Plug the appliance into the AC output socket on the inverter, ensuring it does not exceed the maximum
output power of the inverter
3. Turn the power on/off switch to the ON (I) position.
4. The Power indicator will illuminate green and mains power will be available from the AC output socket(s)
7. INDICATORS & WARNINGS
Power
Illuminates green to show the unit is switched on and power is available from the AC output socket(s)
Over load
Illuminates red if the units has been overloaded due to excessive current or a short circuit
Over temperature
Illuminates yellow if the unit has overheated
Audible alarm
An alarm sound will be heard if the unit has switched off due to a fault
Power
Indicator
Overload
Indicator
Over
Temperature
Indicator Fault Modes Action
Green Off Off Normal Operation -
Orange Off Off Low voltage warning Check for low battery voltage.
Check cable connections are not loose.
Reduce load if possible to extend battery life.
Red Off Off Low voltage shutdown
High voltage shutdown
Switch inverter off, re-charge battery then
switch back on. Check battery voltage is
correct for inverter model i.e. 24volt battery >
24volt inverter.
Red Red Off Over load
Short circuit
RCD tripped
Disconnect all loads, switch inverter off then
back on. If overload indicator is now off:
1. Total load exceeded inverters continuous
rating.
2. Appliance startup current exceeded
inverters surge rating.
3. A connected appliance may have an
electrical fault, test appliances before
re-connecting
Red Off Yellow Over temperature Check for adequate ventilation around inverter
Check inverter cooling fans are working.
8pp A5 (PSW) UK Full Handbook v4.indd 7 07/04/2014 09:48

88
L437
8. SPECIFICATIONS
Model 600 Watt 1000 Watt 2000 Watt 3000 Watt
Continuous Power (up to 12 hours) 600W 1000W 2000W 3000W
Surge Power (up to 1 second) 1200W 2000W 4000W 6000W
Output Voltage 230V AC±10%
Output Frequency 50Hz
Output Waveform Pure Sine Wave
Input Voltage Range 12volt: 10V - 16V
24volt: 20V - 30V
Efficiency > 85%
No Load Current Draw 12volt: < 0.6amp < 1.3amp < 1.5amp < 1.5amp
24volt: - < 1.0amp < 1.0amp -
RCD tripping * - 30mA -
Low Battery Alarm 12volt: 10.5 ± 1 volt
24volt: 21.0 ± 1 volt
Low Battery Shutdown 12volt: 10.0 ± 1 volt
24volt: 20.0 ± 1 volt
Thermal protection 60± 10oC
USB Port 2amp (max) 2amp (max) - -
Dimension (L x W x H) 255 x 225 x 91 394 x 224 x 96 385 x 290 x 96 520 x 286 x 96
Weight 3.5kg 6.3kg 7.7kg 10.8kg
* - only fitted to models RINVPR1000/RINVPR1024/RINVPR2000/RINVPR2024
8pp A5 (PSW) UK Full Handbook v4.indd 8 07/04/2014 09:48
Ce manuel convient aux modèles suivants
10
Table des matières
Autres manuels ring Onduleur

ring
ring POWERSOURCEPURE REINVP600 Manuel utilisateur

ring
ring PowerSourceProRINV1100 Manuel utilisateur

ring
ring PowerSourcePure RINVPAR6 Manuel utilisateur

ring
ring PowerSourcePure Series Manuel utilisateur

ring
ring RSP500 Manuel utilisateur

ring
ring MP:150 Manuel utilisateur

ring
ring PowerSourcePro REINVMA10 Manuel utilisateur

ring
ring PSW-600 Manuel utilisateur

ring
ring PowerSourcePro REINVMA10 Manuel utilisateur