Installation
Operating
Instructions
MaintenanceTroubleshooting
Warranty
Information
Owner’s Manual
DOMESTIC USE ONLY
Please read this document carefully before installing and/or using
your vacuum cleaning system.
Model : _______________ Serial Number : ________________________

2
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed,
including the following.
Read all instructions before using this appliance
WARNING – To reduce the risk of fire, electric shock, or injury:
1. Do not leave appliance when plugged in. Unplug from outlet when not in
use and before servicing.
2. Do not use outdoors or on wet surfaces.
3. Do not allow to be used as a toy. Close attention is necessary when used by
or near children.
4. Use only as described in this manual. Use only manufacturer’s
recommended attachments.
5. Do not use with damaged cord or plug. If appliance is not working as it
should, has been dropped, damaged, left outdoors, or dropped into water,
return it to a service center.
6. Do not pull or carry by cord, use cord as a handle, close a door on cord, or
pull cord around sharp edges or corners. Do not run appliance over cord.
Keep cord away from heated surfaces.
7. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
8. Do not handle plug or appliance with wet hands.
9. Do not put any objects into openings. Do not use with any opening blocked;
keep free of dust, lint, hair, and anything that may reduce air flow.
10. Keep hair, loose clothing, fingers, and all parts of body away from openings
and moving parts.
11. Do not pick up anything that is burning or smoking, such as cigarettes,
matches, or hot ashes.
12. Do not use without dust bag and/or filters in place.
13. Turn off all controls before unplugging.
14. Use extra care when cleaning on stairs.
15. Do not use to pick up flammable or combustible liquids such as gasoline or
use in areas where they may be present.
16. Connect to a properly grounded outlet only. See Grounding Instructions.
SAVE THESE INSTRUCTIONS

3
Table of ConTenTs
Preface .................................................................................... 4
Schematic – Units without Bags ................................................. 5
Schematic – Units with Bags...................................................... 5
Installation
Unit Installation ........................................................................ 6
Dos & Don’ts............................................................................ 7
Mufer Installation - (CI100 and BF100 models)........................ 10
Mufer installation - other models ............................................ 11
Electric Connections................................................................ 11
Grounding Instructions ............................................................ 12
Low Voltage Connections ......................................................... 13
Operating instruction
Hose Hook-up & Inlets............................................................. 14
Using the integrated inlet ........................................................ 15
Progressive Start .................................................................... 16
Automatic Stop ....................................................................... 16
LED indicator .......................................................................... 16
Information center .................................................................. 17
Operating instruction
Motor..................................................................................... 17
Hi Flow Hepa Bag (B20, BF40, BF60 and BF100 models)........... 18
Dirt Receptacle (C20, CI40, CI60 and CI100 models) ................ 19
Filters (C20, CI40, CI60 and CI100 models).............................. 19
Carbon Dust Filter (BF40, BF60 and BF100 models) .................. 20
Troublehooting
General Information ................................................................ 21
Decrease in suction strength ................................................... 22
Vacuum will not start............................................................... 24
Vacuum will not stop ............................................................... 25
Warranty Information
Limited Lifetime Warranty ........................................................ 26

4
PrefaCe
Your new Riccar central vacuum system was designed and manu-
factured in Blainville, Quebec, by the largest central vacuum cleaner
manufacturer in Canada, providing a high-quality, state-of-the-art
product. Our extensive network of qualified professionals ensures first
quality service near you. Contact us for the location of the Riccar autho-
rized service center in your area.
sChemaTiC – UniTs wiThoUT bags (C20, Ci40, Ci60 and Ci100 models)
1. Circuit Breaker
2. Low Voltage Connector
3. Serial Number
4. Integrated Inlet*
5. Air Intake
6. Integrated Switch*
7. Information center*
8. Air Exhaust
9. Muffler
* except C20 model
5
4
3
7
2
1
With mufer turned up 183 cm (72")
With mufer turned down 163 cm (64")
min. 30 cm (12")
min. 30 cm (12")
Recommended 40 cm (16")
min. 30 cm (12")
min. 30 cm (12")
8
9
min. 30 cm (12")
If the muffler is turned down
95 cm (38")
6

5
sChemaTiC – UniTs wiTh bags (b20, bf40, bf60 and bf100 models)
1. Circuit Breaker
2. Information center *
3. Low Voltage Connector
4. Serial Number
5. Upper Round Drum Filter (part #CF-B)
6. Air Intake
7. Carbon Dust Filter*
8. Muffler
* except B20 model
7
With mufer turned up 183 cm (72")
With mufer turned down 163 cm (64")
95 cm (38")
min. 30 cm (12")
min. 30 cm (12")
Recommended 40 cm (16")
min. 30 cm (12")
min. 30 cm (12")
8
min. 30 cm (12")
If the muffler is turned down
6
5
4
2
1
3

gure 1
gure 2
gure 3
6
Installation
UniT insTallaTion
The connections to the piping
system will require some basic
tools: a mitre box and small saw
or a pipe cutter (gure 2). See
pages 9 and 10 for general instruc-
tions pertaining to the preparation
of PVC pipes. To simplify matters,
installation kits, including neces-
sary fittings, pipes, glue and wiring,
as well as a detailed instructions
booklet, are available from
Riccar service centers.
Contrary to all other connections
in the piping system, do not glue
the last tting to your unit. Riccar
central vacuums are equipped
with an adjustable air intake valve
(gure 3), which does not require
glue. An air-tight fit is achieved with
the screw-type adjustment on the
fitting itself.
Using the mounting plate provided
with your vacuum cleaner, secure
the unit to the wall (gure 1), at
a height allowing easy access
for maintenance of the filters,
dirt receptacle and/or bags (see
pages 6 and 7).

7
Installation
dos & don’Ts
Installing Conduits

8
Installation
dos & don’Ts
Installing Conduits

A
A
B
B
A
A
B
B
9
Installation
dos & don’Ts
Installing Inlets
When installing your vacuum inlets, we recommend that the principle of
electric polarity be taken into account. Ensure that the wire connected
onto contact A on inlet 1 is the same as that connected to contact A on
inlet 2, and so on. Do not cross, reverse or interchange wires.
Inlet 1
Inlet 1
Inlet 2
Inlet 2

10
Installation
mUffler insTallaTion (oPTional)
BF100 and CI100 Models
1. Insert the rubber coupling on the vacuum air exhaust.
2. Using a screwdriver, tighten the clamp collars to ensure adequate sealing.
3. Insert the metal elbow into the rubber coupling, and tighten the clamp
collars as per instructions in step 2.
4. Apply metal glue to the metal pipe, and insert it into the 90°
elbow female end.
5. Slide the rubber sleeve on the metal pipe and
90° elbow, all the way to the rubber coupling.
6. Insert another rubber coupling onto the
metal pipe end (0.5 inch, under the sleeve),
and tighten the clamp collars.
7. Insert the male-male adaptor into
the rubber coupling, and tighten the
clamp collars.
8. Apply PVC glue to the visible part
of the male-male adaptor, and
insert the muffler.
*Must be vented outside.
Warning BF100 and CI100 Models
• Donotinstallinasmallenclosedplace
• Neverreduceairexhaustvolume.
• Eachmotorexhaustmustbeseparately
connected to metal conduits of at least
2 inches (5cm) in diameter for a length of
10 inches (25cm). Do not connect both
exhausts to the same conduit.
36” • 91 cm To outdoors
PVC
To outdoors
PVC
36” • 91 cm
Glue not
included
Metal
Ce manuel convient aux modèles suivants
1
Table des matières