RHINO SMS8 Manuel utilisateur

SMS8
Alarm
Control
Panel
8 Zone Alarm Control Panel with LCD Keypad, Inbuilt Dialer
for Back to Base Monitoring and SMS Messaging.
Easy Operation
Dialer
SMS Messaging
Instructions
N11156
Document: SMS8V2.0.doc
Release: 13 August 2003
Models Available
Code Description
SMS8 Alarm with PSTN dialer –
standard model
SMS8GSM Alarm with PSTN and GSM
dialers – extended model

SMS8 Series
RhinoCo Technology © 2002
2
This page intentionally blank.

SMS8 Series
RhinoCo Technology © 2002
3
Contents
Contents..........................................................................................................................3
1. Introduction................................................................................................................6
1.1. Specifications......................................................................................................7
1.1.1. Approvals.....................................................................................................7
1.2. What You Get .....................................................................................................8
2. Installation..................................................................................................................9
2.1. Overview.............................................................................................................9
2.1.1. Wiring Summary........................................................................................10
2.2. The Main Control Panel....................................................................................11
2.3. The Keypad.......................................................................................................12
2.4. The Outside Siren .............................................................................................15
2.5. The Screamer ....................................................................................................18
2.6. The Sensors.......................................................................................................20
2.7. The Backup Battery ..........................................................................................21
2.8. AC Power..........................................................................................................21
3. Operation..................................................................................................................23
3.0. How To ‘Arm’ The System ..............................................................................23
3.1. How To ‘Quick Arm’ The System ...................................................................24
3.2. How To ‘Home Arm’ the System (STAY).......................................................25
3.3. How To ‘Disarm’ The System..........................................................................25
3.4. Phone Operations..............................................................................................26
3.4.0. How to ‘Arm’ via Mobile Phone (GSM model only) ...............................26
3.4.1. How to ‘Disarm’ via Mobile Phone (GSM model only)...........................27
3.4.2. How to Check Status via Mobile Phone (GSM model only) ....................28
3.4.3. Phone Messages (SMS) .............................................................................29
3.5. How To Isolate Zones.......................................................................................30
3.6. How To Enter ‘Test Mode’...............................................................................32
3.5.1. Walk Test...............................................................................................32
3.5.2. Siren & Strobe Test................................................................................33
3.5.3. Dialer Test..............................................................................................33
3.5.4. Battery Test............................................................................................34
3.7. How To Enter ‘Service Mode’..........................................................................35
3.8. Resetting The Alarm.........................................................................................36
3.9. Telephone Line Faults.......................................................................................36
4. Programming............................................................................................................37
4.1. General Programming.......................................................................................37
4.1.1. Quick Programming Guide........................................................................38
4.2. End User Programming.....................................................................................39
4.2.1. How To Enter ‘User Mode’.......................................................................39

SMS8 Series
RhinoCo Technology © 2002
4
4.2.1.1. Changing User Codes.....................................................................40
4.2.1.2. Change the SMS Phone Number.................................................... 41
4.3. Installer Programming......................................................................................42
4.3.1. How To Enter ‘Installer Mode’.................................................................42
4.3.2. Option 1 - Installer Code and User Code Programming........................... 44
4.3.2.1. Changing The Master Code................................................................ 44
4.3.2.2. Changing User Codes.........................................................................45
4.3.3. Option 2 - Zones........................................................................................ 46
4.3.3.1. Zone Type...........................................................................................46
4.3.3.2. Chime .................................................................................................47
4.3.3.3. RF Zone..............................................................................................47
4.3.3.4 Zone Restore........................................................................................ 48
4.3.3.5 Siren Type ...........................................................................................48
4.3.3.6. Zone Isolation..................................................................................... 49
4.3.3.7. Home Mode........................................................................................49
4.3.3.8. Zone Response Time..........................................................................50
4.3.3.9. Pulse Count......................................................................................... 50
4.3.3.10. Zone Name ....................................................................................... 51
4.3.4. Option 3 - Emergency Keys......................................................................52
4.3.4.1. Panic Siren.......................................................................................... 52
4.3.4.2. Medical Siren .....................................................................................53
4.3.4.3. Fire Siren............................................................................................ 54
4.3.5. Option 4 - Timers / Control....................................................................... 55
4.3.5.1. Entry Delay.........................................................................................55
4.3.5.2. Exit Delay........................................................................................... 56
4.3.5.3. Siren Time..........................................................................................56
4.3.5.4. Dial Offset..........................................................................................57
4.3.5.5. Dial Period..........................................................................................57
4.3.5.6. AC Timer Delay................................................................................. 58
4.3.5.7. Battery Offset.....................................................................................58
4.3.5.8. Battery Period..................................................................................... 59
4.3.5.9. Line Delay..........................................................................................60
4.3.5.10. Bell Reverse ..................................................................................... 61
4.3.5.11. RF Tamper........................................................................................61
4.3.5.12. Dial Enable.......................................................................................62
4.3.5.13. RF Remote........................................................................................62
4.3.5.14. Phone Remote (GSM only)..............................................................63
4.3.5.15. Open Override..................................................................................64
4.3.6. Option 5. Dialer.........................................................................................65
4.3.6.1. Account Number ................................................................................65
4.3.6.2. Phone Number 1.................................................................................66
4.3.6.3. Phone Number 2.................................................................................67
4.3.6.4. SMS Network Phone Number............................................................68
4.3.6.5. Receiver 1 Format Type..................................................................... 69

SMS8 Series
RhinoCo Technology © 2002
5
4.3.6.6. Receiver 2 Format Type .....................................................................70
4.3.6.7. Report Routing....................................................................................71
4.3.6.8. Dialer Test Reports.............................................................................72
4.3.7. Option 6. Event Reports.............................................................................73
4.3.7.1. Zone Reports.......................................................................................73
4.3.7.1.1. Alarm Reporting ..........................................................................74
4.3.7.1.2. Restore Reporting ........................................................................74
4.3.7.1.3. Isolation Reporting ......................................................................75
4.3.7.1.4. RF Battery Reporting...................................................................75
4.3.7.1.5. RF Loss Reporting.......................................................................76
4.3.7.2. Events Menu .......................................................................................77
4.3.7.2.1. Open Reporting............................................................................77
4.3.7.2.2. Close Reporting ...........................................................................78
4.3.7.2.3. Panic Reporting............................................................................78
4.3.7.2.4. Medical Reporting .......................................................................79
4.3.7.2.5. Fire Reporting..............................................................................79
4.3.7.2.6. Duress Reporting .........................................................................80
4.3.7.2.7. AC Loss Reporting ......................................................................80
4.3.7.2.8. Low Backup Battery Reporting...................................................81
4.3.7.2.9. Receiver Supervision Reporting..................................................81
4.4. Defaulting The System .....................................................................................83
5. Warranty...................................................................................................................84
5.1. Warning Limitations & Warranty.....................................................................84

SMS8 Series
RhinoCo Technology © 2002
6
1. Introduction
Thank you and congratulations on the purchase of the SMS8 security control panel.
With all the latest technology and ideas, the RhinoCo range of control panels are unique
in simplicity in programming and in use.
The SMS8 offers eight zones, a siren and a strobe output, auxiliary and switched power
terminals for peripherals, and depending on the model purchased, a dialer or dialer and
a GSM backup unit.
All programming is via an alphanumeric LCD keypad and all programming options are
menu driven. The end user options are well laid out and a breeze to operate.
This instruction manual has been designed for ease of reading and also as a quick
reference for any questions you may have about the product.
Proudly Designed and Manufactured in Australia.
Warning!
The manufacturer and or its agents take no responsibility for any damage, injury or
financial loss to any property, equipment or persons resulting from correct or
incorrect use of the RhinoCo range of control panels or its peripherals. The purchaser
assumes all responsibility in the use of any RhinoCo control panel and its
p
eripherals.

SMS8 Series
RhinoCo Technology © 2002
7
1.1. Specifications
3= supported
2
= not supported
SMS8
Stand
ard
SMS8GS
M
Extend
ed
8 Zones
3
3
Maximum of 8 User Codes
3
3
One Installer Code
3
3
Siren Output (rating: 700mA)
3
3
Strobe Output (rating: 700mA)
3
3
Auxiliary Power (rating: 700mA)
3
3
Switched Auxiliary (rating: 200mA)
3
3
Maximum of 4 Keypads
3
3
Dialer
3
3
Contact ID and SMS Protocols
3
3
Short Circuit protection (all outputs)
3
3
Backup to GSM / Pure GSM
2
3
1.1.1. Approvals
This panel meets the following safety and technical standards set by the Australian
Communication Authority:
(Applies to both SMS8 & SMS8GSM)
A-tick
N11156
&
C-tick
N11156

SMS8 Series
RhinoCo Technology © 2002
8
1.2. What You Get
Below is a list of parts included with system.
Item Description Quantity Image
1. Control Panel
This All-In-One unit incorporates the brain of the system.
This include the built in telephone dialer for when
something goes wrong and for back to base reporting
functions. It also includes the metal case.
1
2. Keypad
This keypad has a large 2 line LCD display screen and
additional LED indicators that show the alarms current
state (armed or disarmed). It is used to arm / disarm the
system and other general operation features.
1
3. Tamper Switch
A tamper switch for the main control panel is supplied
along with a bracket to which it mounts. When attached
to the sys 1
4. Accessories
End of Line Resistors (EOLR) are supplied with the
system to provide a high degree of security to the wiring
of the system. These are used on the wiring of each zone. 1
5. Phone Lead
A telephone lead is supplied to connect the security
system to an existing telephone line socket 1

SMS8 Series
RhinoCo Technology © 2002
9
2. Installation
2.1. Overview
A general overview of the components that may be installed with the alarm system is
shown below in the diagram. This also includes an example only of the wires that must
be routed through the roof of the building.
C1
Control Panel
K1
Keypad
N1
Screamer
S1
Smoke Sensor
B1
Main Siren Box
P1
Passive Infrared
Sensor 1
P2
Passive Infrared
Sensor 2
R1
Reed Switch 1
R2
Reed Switch 2
A list of the type of wires that should be run is shown below.
Minimum requirement
Keypad 4 Core cable
Screamer Figure 8 cable (2 cores)
Passive Infrared sensor 4 core security cable
Reed Switch Figure 8 cable (2 cores)
Smoke Detector 4 core security cable

SMS8 Series
RhinoCo Technology © 2002
10
2.1.1. Wiring Summary
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels RHINO Panneau de contrôle