RGBlink MSP 318 Manuel utilisateur

MSP 318
HDMI 2.0 KVM Fiber Extender Set
USER MANUAL
Article No: RGB-RD-UM-MSP318 E001
Revision No: V1.0

MSP 318 User Manual
1
CONTENTS
CONTENTS....................................................................................................................................... 1
Declarations.......................................................................................................................................2
FCC/Warranty............................................................................................................................2
Operators Safety Summary.................................................................................................... 3
Installation Safety Summary...................................................................................................4
Chapter 1 Your Product................................................................................................................... 5
1.1 In the Box............................................................................................................................ 5
1.2 Product Overview...............................................................................................................6
1.2.1 TX................................................................................................................................ 7
1.2.2 RX................................................................................................................................7
1.2.3 Dimension...................................................................................................................9
Chapter 2 Use Your Product..........................................................................................................10
2.1 Operation Steps............................................................................................................... 10
Chapter 3 Caution............................................................................................................................11
Chapter 4 Order Codes................................................................................................................. 12
4.1 Product...............................................................................................................................12
4.2 Module................................................................................................................................12
Chapter 5 Support ........................................................................................................................ 13
5.1 Contact Us........................................................................................................................ 13
Chapter 6 Appendix........................................................................................................................14
6.1 Specification......................................................................................................................14
6.2 Rack Installation............................................................................................................16
6.3Terms & Definitions.......................................................................................................... 17
6.3 Revision History............................................................................................................... 22

MSP 318 User Manual
2
Thank you for choosing our product!
This User Manual is designed to show you how to use this video processor quickly
and make use of all the features. Please read all directions and instructions
carefully before using this product.
Declarations
FCC/Warranty
Federal Communications Commission (FCC)
Statement
This equipment has been tested and found to comply with the limits for a class A digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in a
residential area may cause harmful interference, in which case the user will be
responsible for correcting any interference.
Guarantee and Compensation
RGBlink provides a guarantee relating to perfect manufacturing as part of the legally
stipulated terms of guarantee. On receipt, the purchaser must immediately inspect all
delivered goods for damage incurred during transport, as well as for material and
manufacturing faults. RGBlink must be informed immediately in writing of any
complains.
The period of guarantee begins on the date of transfer of risks, in the case of special
systems and software on the date of commissioning, at latest 30 days after the transfer of
risks. In the event of justified notice of compliant, RGBlink can repair the fault or provide a
replacement at its own discretion within an appropriate period. If this measure proves to
be impossible or unsuccessful, the purchaser can demand a reduction in the purchase
price or cancellation of the contract. All other claims, in particular those relating to
compensation for direct or indirect damage, and also damage attributed to the operation
of software as well as to other service provided by RGBlink, being a component of the
system or independent service, will be deemed invalid provided the damage is not proven
to be attributed to the absence of properties guaranteed in writing or due to the intent or
gross negligence or part of RGBlink.
If the purchaser or a third party carries out modifications or repairs on goods delivered by
RGBlink, or if the goods are handled incorrectly, in particular if the systems are

MSP 318 User Manual
3
commissioned operated incorrectly or if, after the transfer of risks, the goods are subject to
influences not agreed upon in the contract, all guarantee claims of the purchaser will be
rendered invalid. Not included in the guarantee coverage are system failures which are
attributed to programs or special electronic circuitry provided by the purchaser, e.g.
interfaces. Normal wear as well as normal maintenance are not subject to the guarantee
provided by RGBlink either.
The environmental conditions as well as the servicing and maintenance regulations
specified in this manual must be complied with by the customer.
Operators Safety Summary
The general safety information in this summary is for operating personnel.
Do Not Remove Covers or Panels
There are no user-serviceable parts within the unit. Removal of the top cover will expose
dangerous voltages. To avoid personal injury, do not remove the top cover. Do not operate
the unit without the cover installed.
Power Source
This product is intended to operate from a power source that will not apply more than 230
volts rms between the supply conductors or between both supply conductor and ground. A
protective ground connection by way of grounding conductor in the power cord is essential
for safe operation.
Grounding the Product
This product is grounded through the grounding conductor of the power cord. To avoid
electrical shock, plug the power cord into a properly wired receptacle before connecting to
the product input or output terminals. A protective-ground connection by way of the
grounding conductor in the power cord is essential for safe operation.
Use the Proper Power Cord
Use only the power cord and connector specified for your product. Use only a power cord
that is in good condition. Refer cord and connector changes to qualified service personnel.
Use the Proper Fuse
To avoid fire hazard, use only the fuse having identical type, voltage rating, and current
rating characteristics. Refer fuse replacement to qualified service personnel.
Do Not Operate in Explosive Atmospheres
To avoid explosion, do not operate this product in an explosive atmosphere.

MSP 318 User Manual
4
Installation Safety Summary
Safety Precautions
For all MSP 315 processor installation procedures, please observe the following important
safety and handling rules to avoid damage to yourself and the equipment.
To protect users from electric shock, ensure that the chassis connects to earth via the
ground wire provided in the AC power Cord.
The AC Socket-outlet should be installed near the equipment and be easily accessible.
Unpacking and Inspection
Before opening MSP 315 processor shipping box, inspect it for damage. If you find any
damage, notify the shipping carrier immediately for all claims adjustments. As you open
the box, compare its contents against the packing slip. If you find any shortages, contact
your sales representative.
Once you have removed all the components from their packaging and checked that all the
listed components are present, visually inspect the system to ensure there was no
damage during shipping. If there is damage, notify the shipping carrier immediately for all
claims adjustments.
Site Preparation
The environment in which you install your MSP 315 should be clean, properly lit, free from
static, and have adequate power, ventilation, and space for all components.

MSP 318 User Manual
5
Chapter 1 Your Product
1.1 In the Box
2×Power Adapter

MSP 318 User Manual
6
1.2 Product Overview
MSP 318 is an Optical HDMI Extender that overcomes the length restriction of standard HDMI
cables by using optical fiber to send high definition audio and video signals over large distances.
It also built in USB for KVM keyboard mouse for HDMI KVM solution.It is also built in RS232/IR
selection to extend the IR remote control and transfer RS-232 (up to 115kbps) in both directions,
allows you to connect serial devices such as touch screens and barcode scanners.
The key features of MSP 318 are as follows:
● Support 4K@60hz (18Gbps) YUV 4:4:4 8bits, HDR.
● Support HDMI 2.0/HDCP 2.2.
● External SFP+ 10 Giga module for different distance (Order optional)
● IR/RS232/USB function selection.
● Support USB keyboard mouse ( KVM )
● Support Bi-directional IR pass through from 20Khz to 60Khz.
● Support Bi-directional RS232.
MSP 318 System Connection Diagram

MSP 318 User Manual
7
1.2.1 TX
Illumination
1
HDMI IN (HDMI Type A,HDMI input port
to connect to HDMI output of PC or Bluray
player)
2
USB, USB type B to connect to USB-A port of
PC
3
DIP switch for IR, RS232 and USB function
selection
4
LED indicator
5
DC 12V/1.5 A
6
Slot for SPF Fiber module
7
2 3.5mm phone jacks for TX and RX of IR
8
for remote control, connect to PC to
transmit serial command
1.2.2 RX

MSP 318 User Manual
8
Illumination
1
HDMI OUT (HDMI Type A ,HDMI output
port to connect to HDMI port of HD
display such as 4K display)
2
USB, 2 USB type A to connect keyboard and
mouse
3
DIP switch for IR, RS232 and USB function
selection
4
LED indicator
5
DC 12V/1.5A
6
Slot for SPF Fiber module
7
2x3.5mm phone jacks for TX and RX of IR
8
RS232,DB9 male ,to receive RS232 serial
signal,allows users to use touch screen or
barcode scanner.

MSP 318 User Manual
9
1.2.3 Dimension
Following is the dimension of MSP 318 TX and RX for your reference:
Table des matières
Autres manuels RGBlink Extenseur

RGBlink
RGBlink MSP 315 Manuel utilisateur

RGBlink
RGBlink ASK plus Manuel utilisateur

RGBlink
RGBlink MSP 214 Manuel utilisateur

RGBlink
RGBlink MSP530 Manuel utilisateur

RGBlink
RGBlink MSP 215 Manuel utilisateur

RGBlink
RGBlink MSP 226 Manuel utilisateur

RGBlink
RGBlink MSP 215 Manuel utilisateur

RGBlink
RGBlink MSP 214 Manuel utilisateur

RGBlink
RGBlink MSP 227 Manuel utilisateur

RGBlink
RGBlink MSP 225 Manuel utilisateur





















