ENGLISH 6
1. CHOOSING THE RIGHT MOTORCONFIGURATION 6
1.1. POWER CLASS MOTOR 7
1.2. TIMING BELT LENGTH 7
1.3. LOCK CABLE 8
1.4. BUTTON CABLES 10M 8
2. ITEM LIST 11
2.1. ARTICLES NEEDED FOR ASSEMBLY 11
2.1.1. MECHANICAL PARTS 11
2.1.2. CABLES 12
2.2. ARTICLES NEEDED FOR ASSEMBLY IN A CUSTOM
COLOUR PAINT 14
2.3. OPTIONAL ASSEMBLY AIDS 14
3. ASSEMBLY 15
3.1. PREPARATIONS IN WORKSHOP 15
3.2. INSTALLATION ON SITE 25
3.3. CHECKS ON SITE 29
INHOUDSTABEL
NEDERLANDS 30
1. DE JUISTE MOTORCONFIGURATIE KIEZEN 30
1.1. GEWICHTSKLASSE MOTOR 31
1.2. LENGTE VAN DE DISTRIBUTIERIEM 31
1.3. KABEL ELEKTRISCH SLOT 32
1.4. SCHAKELAARKABELS 32
2. ARTIKELLIJST 35
2.1. ASSEMBLAGEBENODIGDHEDEN 35
2.1.1. MECHANISCHE ONDERDELEN 35
2.1.2. KABELS 36
2.2. ASSEMBLAGEBENODIGDHEDEN IN EEN KLEUR OP
MAAT 38
2.3. OPTIONELE ASSEMBLAGEHULPMIDDELEN 38
3. ASSEMBLAGE 39
3.1. VOORBEREIDINGEN IN DE WERKPLAATS 39
3.2. INSTALLATIE TER PLAATSE 49
3.3. CONTROLES TER PLAATSE 53

EnglishNederlandsFrançaisDeutsch
4 5
FRANCAIS 54
1. CHOISIR LA BONNE CONFIGURATION DE MOTEUR 54
1.1. CLASSE DE PUISSANCE MOTEUR 55
1.2. LONGUEUR DE LA COURROIE 55
1.3. CÂBLE DE SERRURE 56
1.4. CÂBLES DE BOUTON 10M 56
2. LISTE D’ÉLÉMENTS 59
2.1. ARTICLES NÉCESSAIRES POUR LE MONTAGE 59
2.1.1. PIÈCES MÉCANIQUES 59
2.1.2. CÂBLES 60
2.2. ARTICLES NÉCESSAIRES POUR LE MONTAGE DANS
UNE PEINTURE PERSONNALISÉE 62
2.3. AIDES AU MONTAGE OPTIONNELLES 62
3. MONTAGE 63
3.1. PRÉPARATIFS EN ATELIER 63
3.2. INSTALLATION SUR SITE 73
3.3. CONTRÔLES SUR SITE 77
DEUTSCH 78
1. AUSWAHL DER RICHTIGEN MOTORKONFIGURATION 78
1.1. MOTORLEISTUNG 79
1.2. ZAHNRIEMENLÄNGE 79
1.3. SCHLOSSKABEL 80
1.4. TASTERKABEL 10M 80
2. ARTIKELLISTE 83
2.1. ZUR MONTAGE NOTWENDIGE ARTIKEL 83
2.1.1. MECHANISCHE BAUTEILE 83
2.1.2. KABEL 84
2.2. ZUR MONTAGE NOTWENDIGE ARTIKEL IN
RAHMENFARBE ZU BESCHICHTEN 86
2.3. OPTIONALE MONTAGEHILFEN 86
3. MONTAGE 87
3.1. VORBEREITUNGEN IN DER WERKSTATT 87
3.2. INSTALLATION VOR ORT 97
3.3. KONTROLLEN VOR ORT 101

EnglishNederlandsFrançaisDeutsch
6 7
1. CHOOSING THE RIGHT MOTORCONFIGURATION
The motor is composed out of several separate components: see section 2 for a
detailed overview of the different article numbers.
The selection of the correct article numbers depends on the following
parameters:
- Weight of the sliding vent
- Sliding Configuration
- Number of sliding vents
- Width of the sliding vent
- Mode of operation/control system
Guidelines and decision matrices to select the correct articles and quantities
can be found in the system catalogues:
HFP 147 089.D25-.--
HFP 179 089.E25-.--
ENGLISH 1.1. POWER CLASS MOTOR
The motor is available in different power classes:
Motor Power rating Article Code
30 W 062.8251.--
50 W 062.8252.--
70 W 062.8253.--
Using the right power class is important to assure the performance and
behaviour of the vent.
An overpowered motor will lead to a jerky motion of
the vent, please do select motors in the right weight
class!
1.2. TIMING BELT LENGTH
The timing belt length is twice the vent stroke length, plus 2m extra for easy
assembly.
The timing belt length can be calculated as follows:
Length (in meters) = (Vent stroke length (in meters) x 2) + 2
The timing belt is available on roll:
Timing belt 10 m (062.8549.--)
OR
Timing belt 30 m (062.8256.--)

EnglishNederlandsFrançaisDeutsch
8 9
1.3. LOCK CABLE
The lock cable (062.8546.--) interconnects the motor with the electrical lock.
This cable has a standard length of 5m and can easily be extended by linking
them together. This was tested up to 15m.
Vent stroke Number of cables
< 7 m 1
7 - 12 m 2
1.4. BUTTON CABLES 10M
The 3 options for the Button Cable are:
ÂCable for Push button 062.8219.--
In this case no button is provided and should be locally sourced or provided by
the electrical installer. This can either be:
1. A Normally Open (NO) Impulse Button
2. A Potential-free relay output of a home automation system. In this
case the motor can be controlled in open loop.
ÂPush button + Cable + Connector 062.8222.--
This is a button cable with a preassembled switch.
ÂPush button + Cable + Connector + LED 062.8547.--
This is a button cable with a preassembled switch with integrated blue 24 V DC
LED ring.

EnglishNederlandsFrançaisDeutsch
10 11
3 “Standard” Control modes are defined:
3 Outputs are available on the Cable Dock to select between these modes:
ÂOCS Control: “Open-Close-Stop”. This is an operation with impulse
functionality. You press the button once and it will open, press again and it
will stop, press again and it will close.
ÂHTR Control: “Hold-To-Run”. As long as the operator pushes the button it
will either open or close.
ÂLock Control: When the button is connected to this output, the button
will only control the electrical lock. This control mode is needed during
installation.
For these 3 standard control modes one single button can be connected to the
motor.
2. ITEM LIST
2.1. ARTICLES NEEDED FOR ASSEMBLY
These articles need to be ordered
individually and are not available in set!
2.1.1. MECHANICAL PARTS
Motor 30W
(062.8251.--)
OR
Motor 50 W
(062.8252.-- )
OR
Motor 70 W
(062.8253.--)
Timing belt 10 m
(062.8549.--)
OR
Timing belt 30 m
(062.8256.--)
Electric Lock for slide motor
(062.8250.--)

EnglishNederlandsFrançaisDeutsch
12 13
Vent Connection
(062.8259.--)
Return Pulley
(062.8255.--)
Cable dock
(062.8254.--)
2.1.2. CABLES
Power Cable 10m
(062.8217.--)
Lock Cable 5m
(062.8546.--)
Cable for Push button 10m
(062.8219.--)
OR
Push button + Cable 10m +
Connector
(062.8222.--)
OR
Push button with LED + Cable 10m
+ Connector
(062.8547.--)

EnglishNederlandsFrançaisDeutsch
14 15
2.2. ARTICLES NEEDED FOR ASSEMBLY IN A CUSTOM
COLOUR PAINT
Motor cover
(062.8258.xx)
Lock support bracket
(062.8249.xx)
Return Pulley cover
(062.8257.xx)
2.3. OPTIONAL ASSEMBLY AIDS
ReynaGlue (084.9106.--)
Cleaning foam (062.9426.04)
3. ASSEMBLY
3.1. PREPARATIONS IN WORKSHOP
• Step 1: Cut profiles to length
• Step 2: Mill profiles
Reference line for the milling is the middle line of the meeting section. For
further detail, please refer to the catalogues and ReynaPro.
HFP 147 089.D25-.--
HFP 179 089.E25-.--
• Step 3: Clean out profiles after milling - inside as well!
Debris and coolant in the profile can get caught up in the timing belt, causing
slippage over the pulley or jamming of the gears. So make sure profiles are
clean.
Recommendation: use a Cleaning mousse (062.9426.04) and push it through
the chamber to clean it out.
Deburr all milled edges with a correct deburring tool.
• Step 4: Place profile with milling upwards on a working table
• Step 5: Place cables in the profile (in total at least 3 cables should be
installed)
a. Lock Cable (062.8546.--) (5 m)
The lock cable interconnects the motor with the electrical lock. The
connector for this cable has a default grey colour. This cable has a
standard length of 5m and can easily be extended.
Vent stroke Number of cables
< 7 m 1
7 - 12 m 2
Use cable tie holders (screwed or glued version) to hold the cable. These
should be placed in the insulation strip and under the rubber block
(062.8081.--) at the meeting section.

EnglishNederlandsFrançaisDeutsch
16 17
Screw fixable cable tie holder Glued or taped cable tie holder
b. Power Supply Cable (062.8217.--) (10 m)
The connector for this cable has a default green colour.
This cable has a standard length of 10m but may not be extended.
Do not extend the Power Cable! Reuse the connector
on a new cable with a bigger copper section. Please
ask for the assistance of a certified electrician to
calculate this section and to mount it.
This needs to be connected to a 24 V DC regulated power supply with a
Class II insulation, protected by a suited residual-current device (RCD).
For the power supply, a 3 A nominal current and a 10 A peak current
rating is required.
Class II insulation symbol
A power supply integrated into the profile is not advised. A wall mount
or DIN rail power supply is preferred.
Please refer to the electrical manual page Section 3.
c. Button Cable: For this cable 3 options are available:
Cable for Push button 062.8219.-- (10 m)
Push button + Cable + Connector 062.8222.-- (10 m)
Push button with LED + Cable + Connector 062.8547.-- (10 m)
To make your selection, see section 1.4.
• Step 6: Cut Timing Belt to length
The timing belt should be cut with an overlength for easy assembly. The
length must be calculated with the following formula:
Length (in meters) = (Vent stroke length (in meters) x 2) + 2
• Step 7: Place Timing belt in the profile.
This can best be achieved by pushing the belt from the motor milling towards
the return pulley milling.
Make sure the teeth are pointing upwards (outwards to the opening) and the
belt is not twisted inside the profile.
Have both ends meet in the middle of the vent stroke.
DO NOT CUT THE BELT TO LENGTH AT THIS POINT!
• Step 8: Assemble the motor holder clamp, adjust the depth of the screw
fixing plate according to the wall thickness of the profile.

EnglishNederlandsFrançaisDeutsch
18 19
• Step 9: Fix the motor holder clamp inside the profile
• Step 10: If necessary turn the pulley of the return pulley to the right.
This can be detected based on the position of the belt in the motor. The
return pulley should match the same side.
1. Remove the locking nut from the return pulley
2. Remove the shaft
3. Switch over the pulley
4. Place the shaft back in
5. Move the shaft to just fit in the slot
6. Screw on the locking nut
• Step 11: Pull the belt through the return pulley
• Step 12: Fix the return pulley in the profile, do not tighten the nut at the
back of the return pulley at this point.