Retrospec iSUP Manuel utilisateur

OWNER’S MANUAL
RETROSPEC ISUP INTELLIGENT ELECTRIC PUMP
This manual contains safety, assembly, use, and maintenance
instructions. Read these instructions carefully before use and
keep them for future reference. Your safety may be aected
if you do not follow these instructions.
20.00
PSI/BAR
+
-
1Introduction
The Retrospec iSUP Intelligent Electric Pump features an intelligent 12 volt DC electric pump with preset pressure LCD screen. With the intelligent pressure system,
you preset a pressure value, when preset pressure is reached, the pump will automatically stop inflating.
2What’s in the box
3
2
1
3Parts,Features, Controls
– Inflation Inlet
– Deflation Outlet
– DC Plug
– Pressure Value LCD Screen
– Pressure Unit Toggle Button
– Inflation Button
– Deflation Button
– On/O Button
– Flex-Hose
– Air Tap
– Flexible Conduit Adapter
1
2
3
4
5678
910
11
Air Pump Flex-Hose with fittings Owner’s Manual
WARNING
1
2
3
4
5
6
7
8
9
10
11

PSI/BAR
+-
5Inflation Operation
4Safety Warnings
WARNING
- Do not use this device for balloons.
- Keep this product away from children.
- To prevent tripping, keep the cord visible and in safe surroundings.
- If you are standing in water or have wet hands, do not plug-in or unplug this device.
- Remove DC plug from socket before moving, maintaining, repairing, adjusting, or cleaning this product.
- To prevent damage by lawnmowers and other power equipment, do not let the cord become obscured by dirt, grass, or debris.
If the pump or its power cord is damaged it must be repaired/replaced by the manufacturer, their service agent, or similar authorized
personnel. Contact Retrospec customer service.
- Before inflating, check and respect the maximum pressure rating of the product you wish to inflate. Exceeding the maximum pressure may damage the product and
cause injury to yourself and those near you.
- Before using, check the cigarette lighter socket to make sure there is no rust, residue, or obstructions. A cigarette lighter socket with poor electrical conduction may
cause overheating of the product and/or power source which can damage the product and/or vehicle.
1Connect Flex-Hose Flexible Conduit Adapter end (11) to the pump Inflation Inlet (1), twist clockwise to tighten (See 1).
2 Install the other end of FlexHose into the paddleboard air tap, twist clockwise to tighten, then insert the inflation valve of the paddleboard, twist clockwise to secure (See 2).
11 2
3Plug DC Plug into 12V DC socket.
4Press the Pressure Unit Toggle Button to select the desired pressure value.
5Press the Inflation Button or Deflation Button to set desired pressure value.
NOTE- Pressure range is 0 to 20 PSI (1 PSI = 0.0689BAR).

6Press On/O Button to start inflation.
7 During inflation, you can press the Inflation Button or Deflation Button to increase or reduce pressure. Press the Pressure Unit Toggle Button to switch
unit of measure. Press On/O Button to stop.
8Press and hold the On/O Button for 3 seconds to directly start the pump.
NOTE- When the pressure reaches the preset pressure value, the pump will stop automatically.
9After inflation is complete, remove DC Plug from the 12V socket, then remove the Flex-Hose from paddleboard and pump. Store it.
NOTE- The factory set pressure value is 10PSI (10PSI=0.689BAR). The pressure value setting at time of last use will be displayed by default.
NOTE-After powering on, if not used within 2 minutes, the pump will enter standby mode. Restart the pump by pressing the On/O Button.
+-PSI/BAR
6Deflation Operation
WARNING
1 Remove the hose from the Inflation Inlet (1) (See 1), then reconnect it to the Deflation Outlet (2), twist clockwise to tighten (See 2).
2Attach the other end to the paddleboard. Press the On/O Button to start the deflation – deflate to desired level or completely. Turn o.
7Operating Warnings
1
- Use only 12V DC power source.
- Do not leave pump unattended while is use.
- Do not expose this pump to rain or moisture. Do not immerse in water.
- To reduce risk, always face Inflation Inlet away from your face and body.
- Do not use this product when the hose is damaged – repair or replace immediately.
- Do not block the Inflation Inlet (1) and Deflation Outlet (2), keep both unobstructed at all times.
2

RETROSPEC.COM (213) 744- 1555 TEAM@RETROSPEC.COM
8Troubleshooting
9Storage/Cleaning
10 Warranty
- Observe local e-waste laws and provisions – it is against the law to dispose of this pump randomly.
- Do not use this air pump if any part is damaged, use only authorized service professionals for repair.
- Never remove the hose during inflation, the high pressure may harm yourself, those near you, or the paddleboard.
- Do not exceed 20 minutes of continuous run time, exceeding this time may cause overheating and internal damage to the motor.
Cool for 30 minutes, before next use.
- Make sure your vehicle is running while using this pump to prevent damage to vehicle, and charging system – battery.
-Make sure your vehicle transmission is in Park and emergency brake(s) set.
Issue
The air pump
cannot be
started
1 The power source is not plugged properly.
2 The fuse in DC plug (7) is burnt out.
3 Overheating or overload causes motor stop.
1 Make sure that the power wire is plugged in the 12V DC socket.
2 Change the fuse.
3 Cool the motor and restart it.
4 If the problem cannot be solved, please contact local service agents or similar authorized personnel to change the product.
30 - minute cooling
1 Clear hose blockage. Repair/replace damaged hose.
2 Reinstall the hose.
3If the problem persists, contact local service professionals or similar authorized personnel for servicing.
Check if the air pump is working too
long and its inside is overheated.
1 Check whether the hose is blocked
or cracked
2 The joint between the hose and air pump or
air bag is not installed properly.
The machine
displays HOT
Slow or abnormal
inflation or
deflation.
Inspection Solution
Retrospec warrants this product to be free from defective materials and workmanship for 1 year from the date of original purchase. Use of
non-original parts and accessories will void warranty.
Always remove DC plug from the socket for storage. Always cool completely before storage. Store in a cool, dry, and ventilated place. Clean
with a dry, soft towel only. Do not use harsh chemicals or solvents.
Table des matières
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur