Retroactive R10C Manuel d'instructions

ECR International Inc
2201 Dwyer Avenue
Utica, NY 13501
e-mail: [email protected]
e Right Fit for Comfort
P/N 240010328, Rev. A [10/15/2013]
An ISO 9001-2008 Certied Company
™
R10C/H R20C/H R35C/H
R45C/H
and R20C with Fedders
Unizone Option
Packaged Terminal Air Conditioner (PTAC)
Packaged Terminal Heat Pump (PTHP)
Installation, Operation,
& Maintenance Manual

TABLE OF CONTENTS
Information and specications outlined in this manual in effect at the
time of printing of this manual. ECR International reserves the right to
discontinue, change specications or system design at any time without
notice and without incurring any obligation, whatsoever.
NOTICE
RetroAire™ replacement PTAC/PTHP is backed
by ECR International and is tested and rated in
accordance with: AHRI Standards 310/380 UL-484
Receiving Information .................................................................................................... 3
Important Safety Information ......................................................................................... 4
Performance Data.......................................................................................................... 5
Dimensional/Physical Data.............................................................................................. 6
Product Description ....................................................................................................... 9
PTAC/PTHP Installation Preparation.................................................................................14
Installation Instructions — R10C | R10H ..........................................................................15
Installation Instructions — R20C| R20H ..........................................................................17
Installation Instructions — R20C With Fedders Uni-Zone Option ..........................................19
Installation Instructions — R35C| R35H...........................................................................21
Installation Instructions — R45C | R45H ..........................................................................23
Sequence Of Operation .................................................................................................25
Inspection & Start-Up ...................................................................................................28
Maintenance ................................................................................................................34
Troubleshooting ...........................................................................................................36
Hydronic Heat Performance............................................................................................37
Electrical Specications .................................................................................................38
Warranty.....................................................................................................................43
The Right Fit for Comfort 2P/N 240010328, Rev. A [10/15/2013]

RECEIVING INFORMATION
Shipping damage MUST be reported to the carrier IMMEDIATELY.
Examine exterior.
Remove cover and examine compressor and piping for signs of damage.
Inspection
Check shipment against bill of lading.
Verify equipment received as ordered.
Verify unit:
• Unit size and type correct per submittal sheet and
job requirements?
• Voltage correct?
• Hydronic coil included, if required? Piping located
as required?
• Factory installed options installed?
• All eld installed options included?
Inspect each component for damage. Concealed damage
must be reported to carrier within 15 days of receipt of
shipment.
• Carrier must make proper notation on delivery receipt
of all damage identied and complete carrier inspection
report.
Purchaser must notify Manufacturer’s Service department
of all damage and is responsible for ling any necessary
claims with carrier.
Customer Service : (800) 228-9364
General Information
Installation shall be completed by qualied agency.
Retain
this manual and warranty for future reference.
Installer review this manual to verify unit has been
installed correctly. Run unit for one complete cycle to
verify proper function.
To obtain technical service or warranty assistance
during or after installation, contact your local
representative.
Visit our web site www.retroaire.com for local
representative listing.
For further assistance call 1-800-325-5479.
When calling for assistance, please have following
information ready:
Model Number_________________________
Serial Number_________________________
Date of installation______________________
P/N 2400103028, Rev. A [10/15/2013] 3Made in USA

IMPORTANT SAFETY INFORMATION
Become Familiar With Symbols
Identifying Potential Hazards.
All eld wiring shall conform to requirements of authority
having jurisdiction or in absence of such requirements:
• United States - National Electrical Code, ANSI/NFPA 70
• Canada - CSA C22.1 Canadian Electrical Code Part 1.
Safety Information
• Installation by qualied personnel.
• Turn off electrical supply before servicing unit.
• Inspect all parts for damage prior to installation and
start-up.
• Do not use unit if it has damaged wiring, is not
working properly, or has been damaged or dropped.
• Connect to properly grounded electrical supply with
proper voltage as stated on rating plate.
• Have proper over current protection (i.e. time- delay
fuse/HACR Breaker) as listed on Rating Plate.
• Connect unit to properly grounded electrical supply.
Do not fail to properly ground this unit.
• Tampering voids all warranties.
DANGER
Indicates a hazardous situation which, if not
avoided, WILL result in death or serious injury.
!
WARNING
Indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
!
CAUTION
Indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
!
NOTICE
Indicates information which should be followed to
ensure proper installation and operation.
WARNING
Fire, explosion, and electrical shock hazard.
Improper installation could result in death or
serious injury. Read this manual and understand all
requirements before beginning installation.
!
WARNING
Tampering with PTAC/PTHP is dangerous and could
result in serious injury or death. Do not modify or
change this unit.
!
The Right Fit for Comfort 4P/N 240010328, Rev. A [10/15/2013]

Table 1 Performance Data - Cooling
Models
R10C R20C
R35C R45C
Voltage
Cooling
Capacity EER
Sensible
Heat
Ratio
Indoor Air
Flow
Fresh Air
Inlet Flow
Outdoor
Sound
Level
Shipping
Weight
Btuh (kW) CFM (L/S) CFM (L/s) dBa lbs (Kg)
R_ _C 09
A 115 9000 (2.7) 9.0
0.79
440 (207.7)
35 (17) 75 140 (63.5)
D208/230 9400 (2.8) 8.9
350 (165.2)
E267/277 440 (207.7
R_ _C 12
A 115 11900 (3.5)
8.4 0.66
400 (188.8)
50 (24) 69 140 (63.5)
D208/230 11700 (3.4)
350 (165.2)
E267/277
440 (207.7)
R_ _C 15 D208/230 14400 (4.2) 7.8 0.69 400 (188.8) 60 (28) 70 140 (63.5)
E267/277 450 (212.4)
R_ _C 18 D 208/230 15600 (4.6) 7.7 0.67
380 (179.3)
95 (45) 69
140 (63.5)
Straight Cooling Nominal Capacities
9,000 12,000 15,000 18,000 Btuh
2.6 3.5 4.4 5.3 kW
PERFORMANCE DATA
Heat Pump Nominal Capacities
9,000 12,000 15,000 Btuh
2.6 3.5 4.4 kW
Table 2 Performance Data - Heating
Models
R10H
R20H
R35H
R45H
Voltage
Cooling
Capacity EER
Indoor
Air Flow
Cooling
Heating
Capacity COP
Indoor
Air Flow
Heating
Sensible
Heat
Ratio
Fresh Air
Flow
Outdoor
Sound
Level
Shipping
Weight
Btuh (kW) CFM (L/S) Btuh (kW)
CFM (L/S) CFM (L/S) dBa lbs
(Kg)
R_ _H 09 D208/230
8800 (2.6)
8.9
350 (165.2) 8500 (2.5 2.7 400 (189) 0.79
35 (17) 75
140
(63.5)
E267/277
9400 (2.8)
8.8
440 (207.7) 9100 (2.7) 450 (212)
R_ _H 12
D208/230
11400 (3.3)
8.4
350 (165.2)
11200 (3.3) 2.6
400 (189)
0.66
50 (24) 69
E267/277
400 (188.8) 450 (212)
R_ _H 15
D208/230
14000 (4.1)
7.8
400 (188.8)
14200 (4.2)
2.5
450 (212)
0.69 60 (28) 7070
E267/277
450 (212.4)
500 (236)
Table 3 Nominal Capacities
P/N 2400103028, Rev. A [10/15/2013] 5Made in USA

DIMENSIONAL/PHYSICAL DATA
Figure 1 R10C R10H Dimensions - Inches (mm)
Figure 2 R20C R20H Dimensions - Inches (mm)
The Right Fit for Comfort 6P/N 240010328, Rev. A [10/15/2013]

CABINET
WALL SLEEVE
AIR FILTER 8" x 30"
PERMANENT
ALUMINUM MESH
[374]
14 3/4"
[100]
4"
[25]
1"
26"
[660]
43"
1091
47"
[1194]
[464]
18 1/4"
[102]
4"
Figure 3 R20C With Fedders Unizone Option - Dimensions - Inches (mm)
DIMENSIONAL/PHYSICAL DATA
Figure 4 R35C R35H Dimensions - Inches (mm)
P/N 2400103028, Rev. A [10/15/2013] 7Made in USA

DIMENSIONAL/PHYSICAL DATA
Figure 5 R45C R45H Dimensions - Inches (mm)
The Right Fit for Comfort 8P/N 240010328, Rev. A [10/15/2013]

Figure 6 R10C R10H Chassis
PRODUCT DESCRIPTION
Fresh Air
Switch
(FAS)
Thermostat
Fan
Speed
Switch
(FSS)
System
Switch
(SS)
Line
Cord
Fan
Cycle
Switch
(FCS)
High
Pressure
Switch
(HPS)
reset
Aquastat Connection
(Factory) Installed
jumper
Hydronic Connection
MTR Valve
Hydronic
NO/NC Switch
Valve Orientation
Switch (VOS)
Rating
Plate
Electrical
Diagram
Fresh Air
Switch
(FAS)
Fan
Speed
Switch
(FSS)
Remote
Unit Mount
Valve Switch
(Hydronic Only)
Figure 7 R20C R20H Chassis
Aquastat Connection
(Factory) Installed
jumper
Hydronic
Connection
MTR Valve
Fan Cycle
Switch (FCS)
Fresh Air
Switch
(FAS)
Thermostat
Fan
Speed
Switch
(FSS)
System
Switch
(SS)
Rating
Plate
Electrical
Diagram
Line
Cord
High Pressure
Switch (HPS)
reset
Remote Mount
Fresh Air
Switch
(FAS)
Fan
Speed
Switch
(FSS)
P/N 2400103028, Rev. A [10/15/2013] 9Made in USA

Thermostat
Fan
Speed
Switch
(FSS)
System
Switch
(SS)
Line
Cord
Fan
Cycle
Switch
(FCS)
High
Pressure
Switch
(HPS)
Aquastat
W/ Jumper
MTR Valve
Hydronic
NO/NC Switch
Valve Orientation
Switch (VOS)
Rating
Plate
Electrical
Diagram
Fresh
Air
Switch
Fresh Air
Switch
(FAS) Fan
Speed
Switch
(FSS)
Remote
Unit Mount
PRODUCT DESCRIPTION
Figure 8 R20C With Fedders Uni-Zone Option
Figure 9 R35C R35H Chassis
Fresh Air
Switch
(FAS)
Fan
Speed
Switch
(FSS)
System
Switch
(SS)
Line
Cord
Fan
Cycle
Switch
(FCS)
High
Pressure
Switch
(HPS)
MTR Valve
Rating
Plate
Electrical
Diagram
Line
Cord
Unit mount & Remote Mount
Aquastat
W/ Jumper
The Right Fit for Comfort 10 P/N 240010328, Rev. A [10/15/2013]
Ce manuel convient aux modèles suivants
7
Table des matières