Rentquip Patron GI-2000 Manuel utilisateur

operation manual
INVERTER
GENERATOR
GI-2000

2
Safety
4 Introduction
5 Safety Warnings
6 Safety Information
Description
10 Description
11 Control Panel
Control Function
12 3 in 1 switch knob
12 Oil warning light (red)
13 Overload indicator light (red)
13 AC pilot light (green)
14 DC protector
14 Engine smart control (ESC)
15 Fuel tank cap
15 Fuel tank cap air vent knob
15 Ground (Earth) terminal
Preparation
16 Fuel
16 Engine oil
17 Pre-operation check
Operation
18 Operation
19 Staring the engine
20 Stopping the engine
21 Alternating Current (AC) connection
21 Battery Charging
23 Application range
table of contents

3
Safety
4 Introduction
5 Safety Warnings
6 Safety Information
Description
10 Description
11 Control Panel
Control Function
12 3 in 1 switch knob
12 Oil warning light (red)
13 Overload indicator light (red)
13 AC pilot light (green)
14 DC protector
14 Engine smart control (ESC)
15 Fuel tank cap
15 Fuel tank cap air vent knob
15 Ground (Earth) terminal
Preparation
16 Fuel
16 Engine oil
17 Pre-operation check
Operation
18 Operation
19 Staring the engine
20 Stopping the engine
21 Alternating Current (AC) connection
21 Battery Charging
23 Application range
table of contents
Maintenance
25 Maintenance
27 Spark plug inspection
28 Carburetor adjustment
28 Engine oil replacement
29 Air filter
30 Muffler screen and spark Arrester
31 Fuel tank filter
31 Fuel filter
Storage
32 Drain the fuel
32 Engine
Troubleshooting
32 Engine won’t start
34 Generator won’t produce power
34 Specifications
35 Wiring Diagram
Parallel Function
36 Parallel function instructions

4
introduction
Using the Operator’s manual
The operating manual is an important part of your generator and should
be read thoroughly before initial use, and referred to often to make sure
adequate safety and service concerns are being addressed.
Reading the owner’s manual thoroughly will help avoid any personal injury
or damage to your machine. By knowing how best to operate this
machine you will be better positioned to show others who may also
operate the unit.
This manual contains information for the complete range of generators,
and was written to take you from the safety requirements to the operating
functions of your machine. You can refer back to the manual at any time
to help troubleshoot any specific operating functions, so store it with the
machine at all times.
Attention: Read through the complete manual
prior to the initial use of your generator.

5
safety
The safety alert symbol ( ) is used with a signal word (DANGER,
CAUTION, WARNING), a pictorial and/or a safety message to alert
you to hazards.
DANGER you WILL be KILLED or SERIOUSLY HURT if you don’t
follow instructions.
WARNING you CAN be KILLED or SERIOUSLY HURT if you don’t
follow instructions.
CAUTION you CAN be HURT if you don’t follow instructions
NOTICE your generator or other property could be damaged if you
don’t follow instructions.
Save these Instructions
Safety Warnings
This is the safety alert symbol. It is used to alert
you to potential personal injury hazards. Obey
all safety messages that follow this symbol to
avoid possible injury or death.
Hazard Symbols and Meanings
explosion
kickback read manual
fire electric shock
toxic fumes

6
safety
1. SAFETY INFORMATION
Read and understand this owner’s manual before operating your
generator. It will help you avoid accidents if you get familiar with your
generator’s safe operation procedures.
WARNING
Generator exhaust contains carbon monoxide, a
poisonous gas that can kill you.
You CANNOT smell or see this gas.
• Use the generator outdoors, away from open windows, vents, or
doors that could allow the carbon monoxide gas to come indoors.
Keep the generator at least 1 meter (3 feet) away from any structure
or building during use.
• NEVER use a generator indoors, including in homes, garages,
basements, crawl spaces, and other enclosed or partially-enclosed
areas, even with ventilation. Opening doors and windows or using
fans will not prevent carbon monoxide build-up in the home.
• NEVER use a generator in enclosed or partially-enclosed spaces.
Generators can produce high levels of carbon monoxide very quickly.
When you use a portable generator, remember that you cannot smell
or see carbon monoxide. Even if you can’t smell exhaust fumes, you
may still be exposed to carbon monoxide.
• NEVER operate the generator in an explosive atmosphere, near
combustible materials or where ventilation is not sufficient to carry
away exhaust fumes. Exhaust fumes can cause serious injury or death.
• If you start to feel sick, dizzy, or weak while using a generator, get
to fresh air RIGHT AWAY. DO NOT DELAY. The carbon monoxide
from generators can rapidly lead to full incapacitation and death.
• If you experience serious symptoms, get medical attention
immediately. Inform medical staff that carbon monoxide poisoning
is suspected. If you experienced symptoms while indoors, have
someone call the fire department to determine when it is safe to
re-enter the building.

7
safety
WARNING
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or death.
When Adding or Draining Fuel
• Observe all safety regulations for the safe handling of fuel. Handle
fuel in safety containers. If the container does not have a spout, use
a funnel.
• Do not overfill the fuel tank, leave room for the fuel to expand.
• Do not refill fuel tank while the engine is running. Before refueling the
generator, turn it off and let it cool down. Gasoline spilled on hot
engine parts could ignite.
• Fill the tank only on an area of bare ground. While fueling the tank,
keep heat, sparks and open flame away. Carefully clean up any spilled
fuel before starting engine.
• Always fill fuel tank in an area with plenty of ventilation to avoid
inhaling dangerous fumes.
• NEVER store fuel for your generator in the home. Gasoline, propane,
kerosene, and other flammable liquids should be stored outside of
living areas in properly-labeled, non-glass safety containers. Do not
store them near a fuel-burning appliance, such as a natural gas water
heater in a garage. If the fuel is spilled or the container is not sealed
properly, invisible vapors from the fuel can travel along the ground and
can be ignited by the appliance’s pilot light or by arcing from electric
switches in the appliance.

8
safety
WARNING
• The GFCI may not function unless the generator is properly
grounded. Follow the correct procedure specified in the section
labeled GROUNDING INSTRUCTIONS.
Ground Fault Circuit Interrupter Protection
These generators are equipped with a GFCI (Ground Fault Circuit
Interrupters) 120V duplex receptacles for protection against the hazards
of electrical shock from defective attachments such as, tools, cords,
and cables.
A GFCI is a device that interrupts electricity from either the utility or
generator by means of a special type of circuit breaker that determines if
a current flow to the ground occurs.
A GFCI can be used only with generators that have the neutral wire
internally bonded to the frame, and the frame properly grounded to the
earth. A GFCI will not work on generators that do not have the neutral
wire bonded to the frame, or on generators which have not been properly
grounded. All BE generators have internally bonded ground wires.

9
safety
DANGER
Improper grounding can result in a risk of electrocution.
Check with a qualified electrician for your local
requirements if you are in doubt as to whether the unit
is properly grounded.
• This generator is equipped with a grounding terminal for added
protection. Using the ground path from the generator to an external
ground source as instructed in the section labeled “Grounding
Instructions” in the Preparation section of this manual can be
necessary. Please consult a qualified electrician for local regulations.
• The generator is a potential source of electrical shock if not kept dry.
Keep the generator dry and do not use in rain or wet conditions. To
protect from moisture, operate it on a dry surface under an open,
canopy-like structure. Dry your hands if wet before touching the
generator.
• Plug appliances directly into the generator. Or, use a heavy duty,
outdoor-rated extension cord that is rated (in watts or amps) at least
equal to the sum of the connected appliance loads. Check that the
entire cord is free of cuts or tears and that the plug has all three
prongs,especially a grounding pin.
• NEVER try to power the house wiring by plugging the generator into
a wall outlet, a practice known as “back feeding”. This is an extremely
dangerous practice that presents an electrocution risk to utility
workers and neighbors served by the same utility transformer. It also
bypasses some of the built-in household circuit protection devices.
• If you must connect the generator to the house wiring to power
appliances, have a qualified electrician install the appropriate
equipment in accordance with local electrical codes.
This product has been designed with internal grounding or floating
bonded neutral. If it should malfunction or breakdown, grounding
provides a path of least resistance for electric current to reduce the risk
of electric shock.

10
description
3. DESCRIPTION
1. Carrying handle
2. Fuel tank cap air vent knob
3. Fuel tank cap
4. Control panel
5. Recoil starter
6. Oil filler cap
7. Louver
8. Muffler
9. Spark plug maintenance cover
Table des matières