Rentokil Connect AutoGate Manuel utilisateur

Connect
AutoGate
Instruction Manual
This manual is based on the latest information and is provided subject to alteration.
Instruction Manual PestConnect / 2017 Version 0.4 GSD-100548
Relates to :
Connect AutoGate – 304765
This product has LongReach Technology Inside

Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Page 2
No part of this document may be reproduced, republished or retransmitted in any form or by any
means, whether electronically or mechanically, including, but not limited to, by way of photocopying,
faxing or recording without the express written permission. We reserve the right to revise this
document without the obligation to notify any person and/or entity. All other company or product
names mentioned are used for identification purposes only and may be trademarks of their respective
owners.
LIMITATION OF LIABILITY AND DAMAGES
The product and the softwares within are provided on an “as is” basis. The manufacturer and
manufacturer’s resellers (collectively known as “The Sellers”) disclaim all warranties, express, implied
or statutory, including and without limitation the implied warranties of non-infringement,
merchantability or fitness for a particular purpose, or any warranties arising from course of dealing,
course of performance, or usage of trade. In no event will the sellers be liable for damages or loss,
including but not limited to direct, indirect, special, wilful, punitive, incidental, exemplary or
consequential damages, damages for loss of business profits, or damages for loss of business of any
customer or third party arising out of the use or the inability to use the product, including but not
limited to those resulting from defects in the product or documentation. In no event shall the sellers’
total cumulative liability of each and every kind in relation to the product exceed the cost to replace
the product.
Product disposal instructions
for residential users
The Waste of Electrical and Electronic Equipment (WEEE) Directive (2002/96/EC) has
been put in place to recycle products using best available recovery and recycling
techniques to minimise the impact on the environment, treat any hazardous
substances and avoid increasing landfill. The symbol shown above and on the product
means that the product is classed as Electrical or Electronic Equipment and you should
not put it into your domestic waste bin. When you’ve no more use for it, please
dispose of the product according to your local authority’s recycling scheme. For more
information, please contact your local authority or the retailer
where you bought the product.
NOTICES

Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Page 3
Safety Instructions
•This product is intended for indoor or outdoor use.
•Only use the battery packs part number 300076 supplied by Rentokil
Initial for this product. NOTE: This battery pack is not rechargeable
and should never be recharged.
•If the AutoGate is stored unused for a long period, the batteries
should be removed.
•Do not use the device if it is damaged.
•Only trained personnel should open the device.
•Do not expose the device to corrosive liquids.
•This device contains Radio Emitting devices and should not be used
near to life support systems.
•This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved.
•Children should be supervised to ensure that they do not play with
the appliance.
Note: If the equipment is used in a manner not specified
by the manufacturer then the protection provided by
the equipment may be impaired.

Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Page 4
Pest Connect Overview
Pest Connect is a system that enables remote monitoring of devices. Data from sensors is sent to
a Connect Control Panel which establishes a secure connection to a central server where the
data is passed to the Rentokil Systems.
Typical sensors that are used in the Pest Connect system are the Connect Radar mouse trap and
the AutoGate Connect, shown below in Figure 1.
A typical installation will have many sensors communicating to the Connect Control Panel and a
single control panel can manage up to 300 sensors. Where necessary multiple Control Panels
could be deployed onto a site and up to 8 co-located control panels are permitted. In such a
system if the sensors fail to connect to the Control Panel they will scan for alternative Control
Panels to ensure high levels of connectivity.
NOTE: The control panels that are suitable for using with AutoGate Connect must also be
equipped with LongReach technology.
Figure 1: Connect System Overview
Radar Connect
AutoGate Connect

Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Page 5
Product Description
AutoGate Connect is a battery powered unit that has been designed to detect rats and provides a barrier
between the entry section of a bait box and the bait section. AutoGate Connect units have two infrared
emitters which continuously pulse light, and are reflected off the rat’s fur, bouncing back to the Infrared
detectors. If the beams from both detectors are broken simultaneously then this counts as one activation.
Once the sensor is triggered 3 times, with at least a five minute interval between each activation, the gate
will open allowing the rats to access the bait in the bait section of the box.
Note: There is a five minute interval between each of the 3 required activations to ensure that the gate is not
triggered three times by one visiting rat.
AutoGate Connect features a motorised door capable of opening and closing. This enables the bait to be
isolated again after the baiting period by automatically closing again after, for example 5 days. There is also
an enhanced display that enables the technician to view, for example, number of days since baiting started,
number of activations and battery level.
The AutoGate Connect units will fit into FT150 and FT155 bait boxes (shown below).

Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Page 6
Hardware Overview

Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Page 7
User Interface
Pressing the push button will activate the display and then successive presses will move the
LED to the next position. The display items are shown below.
Days since Gate was Opened – represents the number of days since the gate was first
opened. This corresponds to the number of days that you have been baiting.
Number of Activations since gate was armed – represents the count of the number of times
that a rat has been in the bait box. This includes when the gate is open and closed.
Battery Percentage Indicator – represents the battery level as a percentage.
Technician Setup – when this item is selected all of the sensors must be activated in order to
arm the AutoGate Connect device.
Gate Armed – means that the AutoGate has been set up correctly. Note: If this LED is lit
together with any of the first 3 then the gate will continue to function after the display goes
out.
Indicating that there have
been 4 activations

Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Page 8
Installing an AutoGate
Open the bait box that you wish to install the AutoGate in.
With the “External LED” on the AutoGate on the right hand side, insert the
AutoGate into place such that the door is in the middle of the bait box and the
support arms are either side of the walls as shown below.

Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Page 9
Setting the AutoGate
Push the button to scroll through the menu in order to set the AutoGate. The
AutoGate is only successfully set when the indicator is displayed.
When the “Technician Setup” is selected then the door will move
up/down/up to test the motor and door sensors. If there is an error then E4 will
be displayed on the display.
After successfully testing the door the display will show 2 dots to indicate that it is
ready to test the sensors as shown below.
Ready to test sensors.
Move hand in front of the Bait side sensor and the middle bars
will be displayed as shown.
Move hand in front of the right hand Entry side sensor and right
bar is displayed as shown.
Move hand in front of the left hand Entry side sensor and left bar
is displayed as shown.
Once all 3 sensors have been tested (in any order) the radio will
scan for connection to a Control Panel. If connected it will display
“r” and a number. The number is the signal strength from 0-9.
E.g. “r8” as shown. If there is no connection only the “r” will be
displayed while scanning.
Once the Gate is tested and connected to the Control Panel the
ON symbol is lit as shown.

Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Page 10
Checking the AutoGate
When the AutoGate is visited there are two options to check the functions:
Checking without resetting the AutoGate:
If the AutoGate is open when visited then it is possible to verify the number of days
that the gate has been open, the number of rodent visits, battery percentage by
pressing the button. The LED will also be lit (see below) in the case that the
AutoGate is armed and in that case the full technician test is not required.
If the technician test is not carried out then the #Days and #Rodents counts on the
display will not be reset and the gate will close as expected after the programmed
number of open days.
Checking with a Service Reset:
If the AutoGate is closed when visited then it is recommended to do a full technician
test. In this case scroll down to the position and carry out the technician test.
This will reset the #Days and #Rodents counts on the display to zero.
Signal Strength Test
When finding a good position to place the bait box and AutoGate it is possible to
run a signal test where the signal strength is shown every 2.5 seconds on the
display.
Scroll to the position until the two dots are displayed (shown blow). Press the
button and the AutoGate will start Signal Strength test mode. Press the button again
to return to the technician test. Note: This mode will timeout after 2 minutes.
In signal strength test mode, a value between “r0” and “r9” will be displayed.
AutoGates should not be deployed when the signal strength shows “r0” and
installing another Control Panel would be advised.