REMKO HGM Manuel utilisateur

Assembly and operating instructions
Read the instructions prior to performing any task!
REMKO PUMP GROUPS HGM / HGU
Instructions for the Technician
0041-2017-11 Edition 2, en_GB

Installation and operating instructions (translation of the orig-
inal)
Read these operating instructions carefully before commis-
sioning / using this device!
These instructions are an integral part of the system and must
always be kept near or on the device.
Subject to modifications; No liability accepted for errors or mis-
prints!

Table of contents
1 Safety and usage instructions............................................................................................................. 4
1.1 General safety notes....................................................................................................................... 4
1.2 Identification of notes...................................................................................................................... 4
1.3 Personnel qualifications.................................................................................................................. 4
1.4 Dangers of failure to observe the safety notes................................................................................ 4
1.5 Safety-conscious working............................................................................................................... 4
1.6 Safety instructions for the operator................................................................................................. 5
1.7 Safety notes for installation and inspection tasks........................................................................... 5
1.8 Unauthorised modification and changes......................................................................................... 5
1.9 Intended use................................................................................................................................... 5
1.10 Safety-conscious working............................................................................................................. 5
1.11 Warranty........................................................................................................................................ 5
1.12 Transport and packaging.............................................................................................................. 6
1.13 Environmental protection and recycling........................................................................................ 6
2 Technical data........................................................................................................................................ 7
2.1 Unit data for pump groups HGM / HGU.......................................................................................... 7
2.2 Unit dimensions and pump group components HGM..................................................................... 8
2.3 Unit dimensions and pump group components HGU...................................................................... 9
2.4 Pump unit data.............................................................................................................................. 10
2.5 Pump unit dimensions................................................................................................................... 11
2.6 Pressure losses............................................................................................................................. 11
2.7 Delivery heights and electrical power............................................................................................ 12
3 Unit description................................................................................................................................... 12
4Installation and assembly.................................................................................................................. 13
4.1 Installation..................................................................................................................................... 13
4.2 Wall installation............................................................................................................................. 13
4.3 Installation on the distributor......................................................................................................... 15
4.4 Positioning of the electric cables................................................................................................... 16
4.5 Setting the mixing valve for the pump group HGM....................................................................... 17
4.6 Installation of the actuator for the pump group HGM.................................................................... 18
4.7 Replacement of the pump............................................................................................................. 19
4.8 Pump group layout........................................................................................................................ 20
4.9 Electrical connection..................................................................................................................... 21
4.10 Installation example.................................................................................................................... 22
5 Troubleshooting.................................................................................................................................. 23
6 Spare parts list for pump groups HGM / HGU.................................................................................. 25
7 Index..................................................................................................................................................... 27
3

1 Safety and
usage instructions
1.1 General safety notes
Carefully read the operating manual before com-
missioning the units for the first time. It contains
useful tips and notes such as hazard warnings to
prevent personal injury and material damage.
Failure to follow the directions in this manual not
only presents a danger to people, the environment
and the system itself, but will void any claims for
liability.
Keep this operating manual and the refrigerant
data sheet near to the units.
1.2 Identification of notes
This section provides an overview of all important
safety aspects for proper protection of people and
safe and fault-free operation.The instructions and
safety notes contained within this manual must be
observed in order to prevent accidents, personal
injury and material damage.
Notes attached directly to the units must be
observed in their entirety and be kept in a fully
legible condition.
Safety notes in this manual are indicated by sym-
bols. Safety notes are introduced with signal words
which help to highlight the magnitude of the danger
in question.
DANGER!
Contact with live parts poses an immediate
danger of death due to electric shock. Damage
to the insulation or individual components may
pose a danger of death.
DANGER!
This combination of symbol and signal word
warns of a situation in which there is immediate
danger, which if not avoided may be fatal or
cause serious injury.
WARNING!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may be fatal or cause
serious injury.
CAUTION!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause injury or mate-
rial and environmental damage.
NOTICE!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause material and
environmental damage.
This symbol highlights useful tips and recom-
mendations as well as information for efficient
and fault-free operation.
1.3 Personnel qualifications
Personnel responsible for commissioning, opera-
tion, maintenance, inspection and installation must
be able to demonstrate that they hold a qualifica-
tion which proves their ability to undertake the
work.
1.4 Dangers of failure to observe
the safety notes
Failure to observe the safety notes may pose a risk
to people, the environment and the units. Failure to
observe the safety notes may void any claims for
damages.
In particular, failure to observe the safety notes
may pose the following risks:
nThe failure of important unit functions.
nThe failure of prescribed methods of mainte-
nance and repair.
nDanger to people on account of electrical and
mechanical effects.
1.5 Safety-conscious working
The safety notes contained in this manual, the
existing national regulations concerning accident
prevention as well as any internal company
working, operating and safety regulations must be
observed.
REMKO PUMP GROUPS HGM / HGU
4

1.6 Safety instructions for the oper-
ator
The operational safety of the units and compo-
nents is only assured providing they are used as
intended and in a fully assembled state.
nThe units and components may only be set up,
installed and maintained by qualified per-
sonnel.
nThe existing regulations concerning accident
prevention must be adhered to.
nDo not operate units or components with
obvious defects or signs of damage.
nContact with equipment parts or components
can lead to burns or injury.
nEnsure that electrical energy does not pose a
risk.
nRegulations of the VDE and the local energy
supply company must be adhered to.
1.7 Safety notes for installation and
inspection tasks
nThe operator must ensure that all inspection
and installation work is carried out by author-
ised and qualified personnel who have thor-
oughly read the operating manual.
nWorks on the pump/system may only be car-
ried out whilst at a standstill as a matter of prin-
ciple.
nAppropriate hazard prevention measures must
be taken to prevent risks to people when per-
forming installation, repair, maintenance or
cleaning work on the units.
nThe setup, connection and operation of the
units and its components must be undertaken
in accordance with the usage and operating
conditions stipulated in this manual and comply
with all applicable regional regulations.
nRegional regulations and laws as well as the
Water Ecology Act must be observed.
nThe power supply should be adapted to the
requirements of the units.
nThe units and components must be kept at an
adequate distance from flammable, explosive,
combustible, abrasive and dirty areas or
atmospheres.
nSafety devices may not be modified or
bypassed.
1.8 Unauthorised modification and
changes
The operational safety of the pump group that was
delivered is guaranteed only with intended use in
accordance with section 1.9 of the operating
instructions. Under no circumstances should the
threshold values specified in the datasheet be
exceeded.
Modifications or changes to units and components
are not permitted and may cause malfunctions.
Safety devices may not be modified or bypassed.
Original replacement parts and accessories
authorised by the manufacturer ensure safety. The
use of other parts may invalidate liability for
resulting consequences.
1.9 Intended use
Due to the type and design of the pump group, it is
only approved for operation as a heating cycle
group. It serves to transport the operating medium
of water into closed heating cycles.
Any different or additional use is a non-intended
use. The manufacturer/supplier assumes no lia-
bility for damages arising from a non-intended use.
The user bears the sole risk in such cases.
Intended use also includes working in accordance
with the operating and installation instructions and
complying with the maintenance requirements.
The threshold values specified in the technical
data must not be exceeded.
1.10 Safety-conscious working
The safety notes contained in this manual, the
existing national regulations concerning accident
prevention as well as any internal company
working, operating and safety regulations must be
observed.
1.11 Warranty
For warranty claims to be considered, it is essential
that the ordering party or its representative com-
plete and return the "certificate of warranty" to
REMKO GmbH & Co. KG at the time when the
units are purchased and commissioned.
The warranty conditions are detailed in the "Gen-
eral business and delivery conditions". Further-
more, only the parties to a contract can conclude
special agreements beyond these conditions. In
this case, contact your contractual partner in the
first instance.
5

1.12 Transport and packaging
The devices are supplied in a sturdy shipping con-
tainer. Please check the equipment immediately
upon delivery and note any damage or missing
parts on the delivery and inform the shipper and
your contractual partner. For later complaints can
not be guaranteed.
WARNING!
Plastic films and bags etc. are dangerous
toys for children!
Why:
- Leave packaging material are not around.
- Packaging material may not be accessible to
children!
1.13 Environmental protection and
recycling
Disposing of packaging
All products are packed for transport in environ-
mentally friendly materials. Make a valuable contri-
bution to reducing waste and sustaining raw mate-
rials. Only dispose of packaging at approved
collection points.
Disposing of the units and their components
For the manufacture of the units and components,
only recyclable materials have been used. Help
protect the environment by ensuring that the units
or components (for example batteries) are not dis-
posed of in household waste, but only in accord-
ance with local regulations and in an environmen-
tally safe manner, e.g. using authorised disposal
and recycling specialists or council collection
points.
REMKO PUMP GROUPS HGM / HGU
6

2 Technical data
2.1 Unit data for pump groups HGM / HGU
Technical properties
Pump group HGM HGU
Maximum operating temperature °C 90
Max. operating pressure bar 10
IG threaded connections UNI EN 10226-1
AG threaded connections UNI ISO 228-1
Pump Wilo Stratos Para 25 / 1-7 T1
Compatible media Water, water-Glycol mixture (maximum 30%)
Thermometer measurement range 0-120°C, 30-250°F
Weight kg 6.9 5.85
Materials
Pump group HGM HGU
Ball valve and check valve
Body made of brass: UNI EN 12164 - CW617N UNI EN 12164 - CW614N
Hydraulic seals PTFE, Viton, EPDM
Motorised mixing valve
Body made of brass: UNI EN 12165 - CW617N ---
Turning part made of brass: UNI EN 12164 - CW614N ---
Hydraulic seals EPDM
Insulation half-shells
Body EPP
Body, seal kg/m360
Body, therm. conductivity (20°C) W/mK 0.039
Body, therm. conductivity (40°C) W/mK 0.041
7

2.2 Unit dimensions and pump group components HGM
Dimensions
Fig. 1: Unit dimensions for pump group HGM
Pump group G G1 L H
HGM 1" IG 1 1/2" AG 125 mm 363 mm
Components
2
1
4
3
6
75
4
1
=
2
=
5
=
3
=
4
=
Fig. 2: Pump group components HGM
1: Circulation pump Wilo Stratos Para 25 / 1-7 T1
2: Ball valve
3: Ball valve with integrated check valve
4: Thermometer
5: Motorised mixing valve
6: Extension
7: Insulation
REMKO PUMP GROUPS HGM / HGU
8

2.3 Unit dimensions and pump group components HGU
Dimensions
Fig. 3: Unit dimensions for pump group HGU
Pump group G G1 L H
HGU 1" F 1 1/2" M 125 mm 363 mm
Components
2
1
4
3
65
4
1
=
2
=
=3
=4
Fig. 4: Pump group components HGU
1: Circulation pump Wilo Stratos Para 25 / 1-7 T1
2: Ball valve
3: Ball valve with integrated check valve
4: Thermometer
5: Ball valve
6: Insulation
9

2.4 Pump unit data
Technical data
Pump group HGM / HGU
Pump type Wilo Stratos Para 25 / 1-7 T1
Maximum delivery volume m34.5
Maximum delivery height m 7.0
Speed rpm 1200 - 4450
Mains voltage 1~230V ± 10% in accordance with DIN IEC 60038
Energy Efficiency Index ( EEI ) £ 0.23
Frequency Hz 50/60 Hz
Insulation class F
Enclosure class IP 44
Rated input P1 W 5 - 70
Nominal width for pipe connection Rp Inch
es 1"
Connection flange thread G Inch
es 1 1/2"
Permitted ambient temperature °C + 40
Maximum relative humidity £ 95%
Permitted conveying media
Heating water (in accordance with VDI 2035/VdTÜV
Tch 1466)
Water/Glycol mixture: maximum mixture ratio is 1:1 (in
mixtures with Glycol, the delivery data of the pump
must be corrected according to the higher viscosity and
depending on the mixture ratio percentage.)
Ethylene/propylene glycol with corrosion protection
inhibitors
- Standard oxygen binding agent
- Standard corrosion protection agent
- Standard combination products
- Standard cooling brines
Permitted medium temperature °C 95
Maximum operating pressure at the pump bar 6.0
Weight kg 2.4
REMKO PUMP GROUPS HGM / HGU
10
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels REMKO Pompe à eau
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur