1 Safety and usage instructions............................................................................................................. 4
1.1 General safety notes....................................................................................................................... 4
1.2 Identification of notes...................................................................................................................... 4
1.3 Personnel qualifications.................................................................................................................. 4
1.4 Dangers of failure to observe the safety notes................................................................................ 4
1.5 Safety-conscious working............................................................................................................... 4
1.6 Safety instructions for the operator................................................................................................. 5
1.7 Safety notes for installation and inspection tasks........................................................................... 5
1.8 Unauthorised modification and changes......................................................................................... 5
1.9 Intended use................................................................................................................................... 5
1.10 Warranty........................................................................................................................................ 5
1.11 Transportation and packaging....................................................................................................... 5
1.12 Environmental protection and recycling........................................................................................ 6
2 Technical data........................................................................................................................................ 7
2.1 Unit data.......................................................................................................................................... 7
2.2 Unit dimensions............................................................................................................................. 11
3 Unit description................................................................................................................................... 14
4Operation............................................................................................................................................. 14
5 Installation instructions for qualified personnel.............................................................................. 15
6 Corrosion protection.......................................................................................................................... 16
7 Installation........................................................................................................................................... 18
8 Flange heating cartridge electrical wiring........................................................................................ 21
9 Before commissioning....................................................................................................................... 22
10 Commissioning................................................................................................................................... 22
11 Care and maintenance........................................................................................................................ 23
12 Shutdown............................................................................................................................................. 24
13 Spare parts list.................................................................................................................................... 25
14 Index..................................................................................................................................................... 26
3

1 Safety and
usage instructions
1.1 General safety notes
Carefully read the operating manual before com-
missioning the units for the first time. It contains
useful tips and notes such as hazard warnings to
prevent personal injury and material damage.
Failure to follow the directions in this manual not
only presents a danger to people, the environment
and the system itself, but will void any claims for
liability.
Keep this operating manual and the refrigerant
data sheet near to the units.
1.2 Identification of notes
This section provides an overview of all important
safety aspects for proper protection of people and
safe and fault-free operation.The instructions and
safety notes contained within this manual must be
observed in order to prevent accidents, personal
injury and material damage.
Notes attached directly to the units must be
observed in their entirety and be kept in a fully
legible condition.
Safety notes in this manual are indicated by sym-
bols. Safety notes are introduced with signal words
which help to highlight the magnitude of the danger
in question.
DANGER!
Contact with live parts poses an immediate
danger of death due to electric shock. Damage
to the insulation or individual components may
pose a danger of death.
DANGER!
This combination of symbol and signal word
warns of a situation in which there is immediate
danger, which if not avoided may be fatal or
cause serious injury.
WARNING!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may be fatal or cause
serious injury.
CAUTION!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause injury or mate-
rial and environmental damage.
NOTICE!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause material and
environmental damage.
This symbol highlights useful tips and recom-
mendations as well as information for efficient
and fault-free operation.
1.3 Personnel qualifications
Personnel responsible for commissioning, opera-
tion, maintenance, inspection and installation must
be able to demonstrate that they hold a qualifica-
tion which proves their ability to undertake the
work.
1.4 Dangers of failure to observe
the safety notes
Failure to observe the safety notes may pose a risk
to people, the environment and the units. Failure to
observe the safety notes may void any claims for
damages.
In particular, failure to observe the safety notes
may pose the following risks:
nThe failure of important unit functions.
nThe failure of prescribed methods of mainte-
nance and repair.
nDanger to people on account of electrical and
mechanical effects.
1.5 Safety-conscious working
The safety notes contained in this manual, the
existing national regulations concerning accident
prevention as well as any internal company
working, operating and safety regulations must be
observed.
REMKO storage tank systems
4

1.6 Safety instructions for the
operator
The operational safety of the units and compo-
nents is only assured providing they are used as
intended and in a fully assembled state.
nThe units and components may only be set up,
installed and maintained by qualified per-
sonnel.
nThe existing regulations concerning accident
prevention must be adhered to.
nDo not operate units or components with
obvious defects or signs of damage.
nContact with equipment parts or components
can lead to burns or injury.
nEnsure that electrical energy does not pose a
risk.
nRegulations of the VDE and the local energy
supply company must be adhered to.
1.7 Safety notes for installation and
inspection tasks
nThe operator must ensure that all inspection
and installation work is carried out by author-
ised and qualified personnel who have thor-
oughly read the operating manual.
nWork on the system may only ever be carried
out when it is stationary.
nAppropriate hazard prevention measures must
be taken to prevent risks to people when per-
forming installation, repair, maintenance or
cleaning work on the units.
nThe setup, connection and operation of the
units and its components must be undertaken
in accordance with the usage and operating
conditions stipulated in this manual and comply
with all applicable regional regulations.
nRegional regulations and laws as well as the
Water Ecology Act must be observed.
nThe power supply should be adapted to the
requirements of the units.
nThe units and components must be kept at an
adequate distance from flammable, explosive,
combustible, abrasive and dirty areas or
atmospheres.
nSafety devices may not be modified or
bypassed.
1.8 Unauthorised modification and
changes
The operational safety of the supplied units/
components is guaranteed when used in line with
intended use in accordance with section 1.9 of the
operating instructions. Under no circumstances
should the threshold values specified in the data-
sheet be exceeded.
Modifications or changes to units and components
are not permitted and may cause malfunctions.
Safety devices may not be modified or bypassed.
Original replacement parts and accessories
authorised by the manufacturer ensure safety. The
use of other parts may invalidate liability for
resulting consequences.
1.9 Intended use
The storage tank is used to store domestic hot
water.
Any different or additional use is a non-intended
use. The manufacturer/supplier assumes no lia-
bility for damages arising from non-intended use.
The user bears the sole risk in such cases.
Intended use also includes working in accordance
with the operating and installation instructions and
complying with the maintenance requirements.
The threshold values specified in the technical
data must not be exceeded.
1.10 Warranty
For warranty claims to be considered, it is essential
that the ordering party or its representative com-
plete and return the "certificate of warranty" to
REMKO GmbH & Co. KG at the time when the
units are purchased and commissioned.
The warranty conditions are detailed in the "Gen-
eral business and delivery conditions". Further-
more, only the parties to a contract can conclude
special agreements beyond these conditions. In
this case, contact your contractual partner in the
first instance.
1.11 Transportation and
packaging
The units are shipped in sturdy transport pack-
aging or within the heat pump housing. Immedi-
ately check the units on delivery and make a note
of any damage or missing parts on the delivery
note. Inform the forwarding agent and contractual
partner. Claims under guarantee made at a later
date will not be accepted.
WARNING!
Plastic films and bags etc. are dangerous
toys for children!
Why:
- Leave packaging material are not around.
- Packaging material may not be accessible to
children!
5

1.12 Environmental protection
and recycling
Disposal of packaging
All products are packed for transport in environ-
mentally friendly materials. Make a valuable contri-
bution to reducing waste and sustaining raw mate-
rials. Only dispose of packaging at approved
collection points.
Disposal of equipment and components
Only recyclable materials are used in the manufac-
ture of the devices and components. Help protect
the environment by ensuring that the devices or
components (for example batteries) are not dis-
posed in household waste, but only in accordance
with local regulations and in an environmentally
safe manner, e.g. using certified firms and recy-
cling specialists or at collection points.
REMKO storage tank systems
6

2 Technical data
2.1 Unit data
Series EWS 200E EWS 300E EWS 500E
Drinking water volume l 168 275 426
Heat exchanger surface m22.0 3.5 6.2
Heat exchanger contents l --- 22.6 43.0
Storage tank volume l 200 300 500
Max. operating pressure bar 10 10 10
Max. permissible operating temp. °C 95 95 95
Max. drawing quantity when
drawing continuously at 45 °C 1) l/min --- 19.8 22.8
Standby energy
Consumption value 2) kWh/d 1.23 1.78
Standby losses 24h kWh/24h 1.37 2.3 1.88
NL count 8.0 7,5 3) 13,5 3) / 21,6 4)
Energy efficiency ratio B B B
Max. installation length for flange
heater mm 200 450 450
Height mm 1340
Tilt height mm 1455 1595 2023
Diameter mm 550 760 750
Weight kg 90 173 222
1) te=10, Tv=55 °C, Tm=45 °C, Q=3000 l/h
2) Energy consumption in standby according to DIN 44 532 with 50 °C storage tank temperature and 45 °C
tap temperature.
3) NLcount according to EN 12897 and DIN 4708 at 50 °C storage tank temperature, 55 °C inlet temperature,
Q = 3000 l/h and 45 °C tap temperature
4) NLcount according to EN 12897 and DIN 4708 at 65 °C storage tank temperature, 80 °C inlet temperature,
Q = 3000 l/h and 45 °C tap temperature
We reserve the right to make technical changes for the purpose of technical advancement.
7

Throughputs EWS 200E
Throughputs EWS 200E Preparation for domestic water
Inlet temperature °C 55 55 55 55
Hot water temperature °C 45 45 45 45
Cold water temperature °C 10 10 10 10
Heating cycle flow rate l/h 600 1200 1800 2400
Throughput kW
Throughputs EWS 200E Preparation for domestic water
Inlet temperature °C 60 60 60 60
Hot water temperature °C 50 50 50 50
Cold water temperature °C 10 10 10 10
Heating cycle flow rate l/h 600 1200 1800 2400
Throughput kW
Throughputs EWS 200E Preparation for domestic water
Inlet temperature °C 65 65 65 65
Hot water temperature °C 55 55 55 55
Cold water temperature °C 10 10 10 10
Heating cycle flow rate l/h 600 1200 1800 2400
Throughput kW
We reserve the right to make technical changes for the purpose of technical advancement.
REMKO storage tank systems
8

Throughputs EWS 300E
Throughputs EWS 300E Preparation for domestic water
Inlet temperature °C 55 55 55 55
Hot water temperature °C 45 45 45 45
Cold water temperature °C 10 10 10 10
Heating cycle flow rate l/h 600 1200 1800 2400
Throughput kW 16.8 25.3 30.1 33.2
Throughputs EWS 300E Preparation for domestic water
Inlet temperature °C 60 60 60 60
Hot water temperature °C 50 50 50 50
Cold water temperature °C 10 10 10 10
Heating cycle flow rate l/h 600 1200 1800 2400
Throughput kW 18.7 28.1 33.7 37.0
Throughputs EWS 300E Preparation for domestic water
Inlet temperature °C 65 65 65 65
Hot water temperature °C 55 55 55 55
Cold water temperature °C 10 10 10 10
Heating cycle flow rate l/h 600 1200 1800 2400
Throughput kW 20.6 30.9 36.9 40.9
We reserve the right to make technical changes for the purpose of technical advancement.
9

Throughputs EWS 500E
Throughputs EWS 500E Preparation for domestic water
Inlet temperature °C 55 55 55 55
Hot water temperature °C 45 45 45 45
Cold water temperature °C 10 10 10 10
Heating cycle flow rate l/h 600 1200 1800 2400
Throughput kW 22 34 44 51
Throughputs EWS 500E Preparation for domestic water
Inlet temperature °C 60 60 60 60
Hot water temperature °C 50 50 50 50
Cold water temperature °C 10 10 10 10
Heating cycle flow rate l/h 600 1200 1800 2400
Throughput kW 25 42 55 63
Throughputs EWS 500E Preparation for domestic water
Inlet temperature °C 65 65 65 65
Hot water temperature °C 55 55 55 55
Cold water temperature °C 10 10 10 10
Heating cycle flow rate l/h 600 1200 1800 2400
Throughput kW 30 49 63 75
REMKO storage tank systems
10
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels REMKO Chauffe-eau
Manuels Chauffe-eau populaires d'autres marques

Kenmore
Kenmore 153.582400 Manuel utilisateur

Applimo
Applimo Edel AIR Manuel utilisateur

STIEBEL ELTRON
STIEBEL ELTRON Eltronom SHU 5 S Manuel utilisateur

clage
clage E-Mini Series Manuel utilisateur

Toyotomi
Toyotomi Oil Miser OM-180 Manuel utilisateur

Bradford White
Bradford White EF Series Manuel utilisateur