Regency 600PHSPUMP Manuel utilisateur

WATER PUMP
FOR PORTABLE SINKS
USER MANUAL
#600PHSPUMP
REGENCYTABLESANDSINKS.COM
07/2021
OWNER’S MANUAL
NON-SUBMERSIBLE
TRANSFER PUMP
.
Model ZE00805

2
PERFORMANCE
SAFETY INSTRUCTIONS
Item # HP
GPH of Water @ Total Feet of Lift Max.
Lift
0 ft. 10 ft. 20 ft. 30 ft. 42 ft.
600PHSPUMP 1/10 320 GPH 280 GPH 190 GPH 90 GPH 0 GPH
1. Do not pump ammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence
of ammable or explosive vapors. Using this pump with or near ammable liquids can cause an explosion or re,
resulng in property damage, serious personal injury, and/or death.
2. ALWAYS disconnect the power to the pump before servicing.
3. Do not touch the motor housing during operaon. The motor is designed to operate at high temperatures. Do not
disassemble the motor housing.
4. Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water
before disconnecng the power.
5. Release all pressure and drain all water from the system before servicing any component.
6. Secure the discharge line before starng the pump. An unsecured discharge line will whip, possibly causing personal
injury, and/or property damage.
7. Extension cords may not deliver sucient voltage to the pump motor. Extension cords present a life threatening
safety hazard if the insulaon becomes damaged or the connecon ends fall into water. The use of an extension cord
to power this pump is not permied.
8. Wear safety goggles at all mes when working with pumps.
9. This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3 conductor
cord and 3 prong grounded plug. Do not remove the ground pin under any circumstances. The 3 prong plug must
be directly inserted into a properly installed and grounded 3 prong, grounding type receptacle. Do not use this
pump with a 2 prong wall outlet. Replace the 2 prong outlet with a properly grounded 3 prong receptacle (a GFCI
outlet) installed in accordance with the Naonal Electrical Code and local codes and ordinances. All wiring should be
performed by a qualied electrician.
10. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use
damaged or worn cords.
11. Failure to comply with the instrucon and designed operaon of this unit may void the warranty. ATTEMPTING TO
USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
12. Ensure that the electrical circuit to the pump is protected by a 5 amp minimum (15 amp max.) fuse or circuit breaker.
13. Do not li the pump by the power cord.
14. Know the pump and its applicaons, limitaons, and potenal hazards.
15. Periodically inspect the pump and system components to ensure the pump sucon screen is free of mud, sand, and
debris. Disconnect the pump from the power supply before inspecng.
16. Follow all local electrical and safety codes, along with the Naonal Electrical Code (NEC). In addion, all
Occupaonal Safety and Health Administraon (OSHA) guidelines must be followed.
17. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will
reset itself once the motor cools down and an acceptable temperature has been reached. The pump may start
unexpectedly if it is plugged in.
18. Ensure the electrical power source is adequate for the requirements of the pump.
19. Before using the pump, check the hose for holes or excess wear, which could cause leaks, and ensure the hose is not
kinked or making sharp angles. A straight hose allows the pump to move the greatest amount of water quickly, and
also check that all hose connecons are ght to minimize leaks.
20. This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long me
when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris
may cause the pump to fail. Please carefully read the manual and follow the instrucons regarding common pump
problems and remedies.

3
PRE-INSTALLATION
INSTALLATION
APPLICATION
POWER SUPPLY
AREAS OF USE
INSTALLATION INSTRUCTIONS
SPECIFICATIONS
POWER SUPPLY 115V • 60 Hz
LIQUID TEMP. RANGE 32-95°F
DISCHARGE
CONNECTION
POWER CORD
• This pump is designed for operang portable hand washing staons by transferring clean water from storage
tanks to the sink faucet.
• A xed pipeline
• A exible hose
1. The pump is equipped with a shock-proof plug according to regulaons. The pump is designed to be connected to
120 VAC, 60 Hz GFCI protected socket.
2. Make sure that the socket is suciently secured and is in excellent condion.
NOTE: Do not allow the pump to hang suspended by the power cord, inlet pipe or hose. The pump must be set on a
stable surface or suspended from the handle. To ensure that the pump works properly, keep the intake area free from
sludge and dirt of all kinds.
The pump must be installed in a staonary posion with either:
1. This pump is designed to pump clear water only.
2. This pump should be used for transferring clean water within the portable hand washing staon.
1. Aach hose to Pump intake port. Aach second hose to Pump discharge port.
2. Posion Pump on solid surface so that both hoses are free from kinks.
3. Place unused end of intake hose in water to be transferred. Place unused end of discharge hose as needed to direct
the water discharge at least 3 feet away from the source.
WARNING: To prevent death from electric shock, pump must be connected only to a GFCI
protected outlet.
WARNING: If the power cord or plug is damaged, do not use the pump. The power cord or plug may
only be repaired by a cered electrician.

4
OPERATION
CARE & CLEANING
1. Verify that the discharge pipe is properly connected.
2. Verify that the electrical connecon is 120 VAC, 60 Hz.
3. Verify that the electrical socket is GFCI protected and
in good condion.
4. Test GFCI protected outlet before use.
5. Verify that water and moisture cannot get near the
power supply socket.
6. Verify that the pump is installed so as to prevent
running dry.
7. Once plugged in, the pump will connue pumping unl
it is unplugged.
Aer reading these instrucons, consider the following points
before starng the pump: GFCI-Protected
120V Socket
12 3 4
5 8
96 7
NOTE: Do not disassemble the motor housing. This motor has NO repairable internal parts, and disassembly may cause
leakage or dangerous electrical wiring issues.
NOTE: Do not li up the pump by the power cord.
IF THE PUMP IS NOT
RUNNING PROPERLY:
1. Remove the Impeller Cover Screws (1).
2. Remove the Impeller Cover (2).
3. Inspect the Gasket (3) and Impeller (4). If the Impeller
wears out, replace it. The brushes could run up to
200 hours. If the brushes have been worn o,
replace the Brush.
4. The Brush must enter the square hole. Match the Brush
curve to the armature curve.
Item Description Qty
1 4
2 1
3 1
4 1
5 1
6 2
7 1
8 1
9 1

5
TROUBLESHOOTING
Problem Possible Cause Corrective Action
Table des matières
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur