Regal Century V-GREEN 165 Manuel utilisateur

165
VARIABLE SPEED USER MANUAL
PremiumEfciencyVariableSpeedMotor
10019878-001-001 _V-Green165 UM_7-30-19.indd 1 8/5/2019 4:26:54 PM

COPYRIGHT
Copyright 2016, Regal Beloit America, Inc.
Tipp City, Ohio. All rights reserved.
TRADEMARKS
All trademarks and registered trademarks® are the property of their
respective companies. The information in this document incorporates
proprietary rights and is not to be duplicated wholly or in part without
the express written permission of Regal Beloit Corporation and / or
Regal Beloit America, Inc.
January 2016/USA
10019878-001-001 _V-Green165 UM_7-30-19.indd 2 8/5/2019 4:26:54 PM

Table of Contents
Safety ..................................................................................................... 2
1. Introduction ................................................................................... 3
2. Navigation Overview..................................................................... 3
3. Quick Start Instruction ................................................................. 5
3.1 QuickStartGuide(UsingFactoryDefaultSchedule) ........................ 5
3.2 QuickStartGuide(UserDenedCustomSchedule) ........................ 6
4. Overview ........................................................................................ 8
5. Wiring ............................................................................................ 9
6. User Interface Operation ............................................................ 12
6.1 LEDandFunctionOverview..................................................... 12
6.2 UserInterfaceKeyPadOverview .............................................. 13
6.3 SettheSchedule ................................................................... 13
6.4 RunningVGreen165fromKeyPad ........................................... 15
6.5 OVERRIDE .......................................................................... 17
6.6 ScheduleAdvance ................................................................. 18
6.7 KeyLockout ......................................................................... 20
6.8 MotorPause......................................................................... 21
6.9 TemporaryStopwithDigital/SerialInput .................................... 21
6.10 ResetFactoryDefaults............................................................ 22
7. Priming......................................................................................... 22
8. Freeze Protection ........................................................................ 22
9. Control with Digital Inputs ......................................................... 23
10. DIP Switches................................................................................ 24
11. Care and Maintenance ................................................................ 25
12. FAULT Status ............................................................................... 25
13. Specications.............................................................................. 27
14. Troubleshooting Guide............................................................... 28
1
10019878-001-001 _V-Green165 UM_7-30-19.indd 3 8/5/2019 4:26:55 PM

2
SAFETY
Safety is emphasized throughout this user manual. These are safety
alert symbols and signal words. They alert the user to potential per-
sonal injury hazards. Obey all safety messages to avoid possible injury
or death or damage to equipment and other property.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
NOTICE
NOTICE identies potential equipment damage or failure conditions
and alerts personnel to potentially dangerous situations.
DANGER
NOTICE
10019878-001-001 _V-Green165 UM_7-30-19.indd 4 8/5/2019 4:26:55 PM

1 Introduction
The VGreen® 165 is a premium e ciency variable speed motor that
provides tremendous program exibility in terms of motor speed
and time settings. The variable speed VGreen 165 is intended to
enable running at the lowest speeds needed to maintain a sanitary
environment, which in turn minimizes energy consumption. Pool size,
the presence of additional water features, chemicals used to maintain
sanitary conditions, and environmental factors will impact optimal
programming necessary to maximize energy conservation.
The integrated electronics interface controls the speed settings as
well as the run durations. The VGreen 165 can run at speeds ranging
between 600 and 3450 RPM and is rated for 208-230 Vrms at an input
frequency of 60 Hz.
2 Navigation Overview
+, - Increases/decreases selected value
Pressing any key following a change accepts the current value
displayed inside the setting
Figure 1: VGreen 165 User Interface Button Descriptions
3
Programming Buttons (4x)
Power LED
Fault LED
Stop Button
Start Button
Active Step LEDs (4x)
Speed LED
Duration LED
Bar Graph
+/- Buttons
The VGreen 165 is for use with 208-230 Vrms nominal, and in pool pump applications
ONLY. Connection to the wrong voltage, or use in other application may cause damage
to equipment or personal injury.
10019878-001-001 _V-Green165 UM_7-30-19.indd 5 8/5/2019 4:26:55 PM

4
Note: The START button must be pressed for the VGreen 165 to
operate. The START LED will illuminate after the button has been
pressed indicating the VGreen 165 is capable of operating. Pressing
the stop button will turn o the START LED and stop the motor if
running.
VGreen 165 Features
• Simple user interface
• Digital inputs for compatibility with pool automation systems
• Motor design reduces noise emissions
• UV and rain-proof enclosure
• Freeze Protection
• Manual OVERRIDE
• Compatibility w/ VGreen 270 user interface
(sold as a separate accessory)
• High eciency electromechanical motor and control design
BenetsofaddinganoptionalVGreen270
user interface with the VGreen 165 motor
• Ability to conduct eld troubleshooting (i.e., view FAULT codes and
real time operating parameters).
• Ability to set a pump running schedule based on a real clock setting
(i.e., must input actual time which then determines pump start and
stop times).
• Ability to remotely mount the VGreen 270 user interface (provides
easy access of user interface depending on pump location).
• Ability to congure prime speed and prime duration.
If power is connected to the VGreen 165 motor, pressing any of the following buttons
referred to in section 2 could result in the motor starting. Failure to recognize this could
result in personal injury or damage to equipment.
10019878-001-001 _V-Green165 UM_7-30-19.indd 6 8/5/2019 4:26:55 PM

5
• Ability to congure freeze protection temperature.
• Ability to view actual speed and power of the VGreen 165 in real time.
• Ability to adjust the VGreen 165 motor speed in 25 RPM
increments (to ne tune ow for certain pool installations).
• Battery backup to store time setting.
3 Quick Start Instruction
3.1 Quick Start Guide (Usingthefactorydefaultschedule)
The following table describes the factory default settings for DURATION
and SPEED order:
Pressing the START key will start the VGreen 165 based on the factory
default schedule.
NOTE: If power is cycled to the VGreen 165 and the user does not
press the STOP key, the VGreen 165 will automatically start and run
the programmed default schedule shown in the chart above. This
feature ensures that the VGreen 165 will re-start in the event of a power
outage.
Button Duration
(In Hours)
Speed
(In RPM)
STEP 1 4 3100
STEP 2 4 2600
STEP 3 8 1600
OVERRIDE 2 3450
If power is connected to the VGreen 165 motor, pressing any of the following buttons
referred to in section 3 could result in the motor starting. Failure to recognize this could
result in personal injury or damage to equipment.
10019878-001-001 _V-Green165 UM_7-30-19.indd 7 8/5/2019 4:26:55 PM

6
3.2 Quick Start Guide (User-denedcustomschedule)
A VGreen 165 user can set the program DURATION and SPEED for
STEP 1, STEP 2, STEP 3 & OVERRIDE keys.
NOTE: VGreen 165 must be Stopped (Press STOP Key) for program-
ming DURATION and SPEED of the STEP 1, STEP 2, and STEP 3
keys. OVERRIDE DURATION and SPEED can be programmed when
the VGreen 165 is either stopped or running.
Press the STEP 1 key. The STEP 1 button and DURATION setting
LEDs will illuminate. The bar graph will show default DURATION for
STEP 1.
1. Press UP (+) or DOWN (-) arrows to change the DURATION
2. Press the STEP 1 key again to change the SPEED setting.
The SPEED setting LED will illuminate. The bar graph will
show default SPEED for STEP 1.
3. Press UP (+) or DOWN (-) arrows to change the SPEED.
4. Press any STEP or OVERRIDE key to save the DURATION
and SPEED settings for STEP 1. If the user decides not to
save the settings, pressing the STOP key will revert back to the
previously stored setting.
10019878-001-001 _V-Green165 UM_7-30-19.indd 8 8/5/2019 4:26:55 PM

5. Press STEP 2, STEP 3, or OVERRIDE key. Repeat steps 1- 4
to program the corresponding DURATION and SPEED for each
button.
6. Press START to run the VGreen 165 based on the pro-
grammed 24 hour schedule.
7. Pressing the STOP button will stop the VGreen 165.
NOTE: The VGreen 165 can only be set to operate on a 24-hour sched-
ule. If a user attempts to program a schedule with a combined dura-
tion for all three steps greater than 24 hours, the VGreen 165 software
will retain the current STEP time duration only, and will zero out the
other two STEP time settings. As an example, if STEP 1 equals eight
(8) hours, STEP 2 equals nine (9) hours, and STEP 3 equals eight
(8) hours – for a combined 25 hours – the VGreen 165 will retain the
setting for the current Step being programed and zero out the remain-
ing two. For details regarding the set-up of the three steps as part of a
24-hour schedule, see section 6.
7
10019878-001-001 _V-Green165 UM_7-30-19.indd 9 8/5/2019 4:26:55 PM

8
4 Overview
Program customization may require some trial-and-error to determine
the most satisfactory settings as dictated by the conditions. In all cases,
setting the VGreen 165 at the lowest speed for the longest duration is
the best strategy to minimize energy consumption. However, conditions
may require running the
VGreen 165
at a higher speed for some dura-
tion of time each day to maintain proper ltration to achieve satisfactory
sanitation.
The User Interface is located on top of the
VGreen 165
. To the right of
the STEP buttons is the OVERRIDE button. This button can be used
to operate the
VGreen 165
at speeds outside of the normal operating
schedule.
Figure 2: VGreen 165 Overview
DIP Switch
Serial Connector
Digital Inputs
Mains Connections
Keypad Buttons
NOTICE
The VGreen 165 can and should be optimized to suit individual pool conditions. Speci c
conditions including pool size, other devices, features, and environmental factors can
all impact the optimal settings.
10019878-001-001 _V-Green165 UM_7-30-19.indd 10 8/5/2019 4:26:57 PM
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels Regal Moteur

Regal
Regal genteq Evergreen OM Manuel utilisateur

Regal
Regal Century VGreen 085 Manuel utilisateur

Regal
Regal genteq ECM Manuel utilisateur

Regal
Regal Genteq Evergreen EM Manuel utilisateur

Regal
Regal Genteq Evergreen OM Manuel utilisateur

Regal
Regal genteq Evergreen OM Manuel utilisateur

Regal
Regal Century Manuel

Regal
Regal genteq Evergreen CM Manuel utilisateur

Regal
Regal Century VGreen 270 Manuel utilisateur

Regal
Regal Century VGreen Evo Mode d’emploi