Redx RX Series Manuel utilisateur

RX SERIES HYBRID INVERTER
RX-7000HY
RX-5000HY
User Manual


No part of this document can be reproduced in any form or by any means without the prior written
permission of Redx.
and other Redx trademarks used in this manual are owned by Redx.
All other trademarks or registered trademarks mentioned in this document are owned by
their respective owners.
It is prohibited to use data confirmed in firmware or software developed by Redx, in part or in full,
for commercial purposes by any means.
It is prohibited to perform reverse engineering, cracking, or any other operations that compromise
the original program design of the software developed by Redx.
All Rights Reserved
Trademarks
Software Licenses
Contact Us
Redx Technology Australia Pty Ltd
Address: U2 / 21 Millennium Circuit, Helensvale, Australia 4212
Tel: +61 7 5672 9983
Email: [email protected]
Website: www.redx.com.au

This manual mainly describes the product information, installation, operation, and maintenance
guidelines of the Redx Hybrid inverter (RX-7000HY/5000HY). Please read this manual carefully
before using this product and store the manual in a safe place. Redx will not notify the user of
any changes to this manual.
About This Manual
This manual applies to the RX-7000HY/5000HY Hybrid inverter. The inverter must be installed
by a qualified/licensed technician electrical. We strongly recommend that installers read this manual
carefully. The manual includes the guidance on product installation, troubleshooting, communication
and other aspects

Contents
1 Safety……….………………………………...……………..........................................................1
1.1 Important Safety Instructions……….………………………………...….......................... 4
2 Product Introduction……….………………………………...…………….................................4
2.1 System Diagram……….………………………………...……………...............................4
2.2 Product Details……….………………………………...………........................................ 7
2.3
Led Indicator Panel and Switches
……….……………………………..........................10
2.4 Technical Data ……….……………………………........................................................12
2.5 Product Features……….………………………………...………..................................... 14
3 Installation……….………………………………...……………..................................................17
3.1 Installation Preparation……….………………………………...……...............................17
3.2 Installation Tools……….………………………………...……………..............................18
4 Installation Guide……….………………………………...……………......................................19
4.1 Mounting Guide…….……………………………..…...…….............................................19
5 Electrical Connection……….………………………………...……………................................20
5.1 Battery Connection……….………........................……………………...……................22
5.2 Port Instructions ….……………….……………...……...................................................23
5.3 Earth Connection……….………………………………...……........................................ 23
5.4 Battery Power Cable Wiring……….……………………………….................................. 23
5.5 PV Connection……………………..... .....................….................................................. 24
5.6 WiFi/4G Dongle…………..... ..............................…......................................................25
5.7
Communication Connection
…………...........................................................................26
5.8 Grid Connection………….............................................................................................28
5.9
Load Connection
…………............................................................................................28
6 Operation……….………………………………...……………………….....................................29
6.1 Checklist Before Operation……….……………………………….....…...........................29
6.2 Operation Checks……….………………………………...…………….............................31
6.3 Operation Modes……….………………………………...……………..............................31
7 RX-7000HY/5000HY System Turn On and Turn Off……….…………………….....…............33
7.1 Turn on / off RX-7000HY/5000HY……….………………………...….............................33
6.4 Communication ……….….....................……….……………………...............................33
8 Troubleshooting & Maintenance……….………………………………...................................33
8.1 Troubleshooting……….………………………………...…………...................................33
8.2 Maintenance……….………………………………...…………….....................................36
8.3 Routine Maintenance……….………………………………...………..............................37
9 Redx Power App……….………………………………...……………........................................38
10 Quality Assurance……….………………………………...……………...................................38
11 Appendix……….………………………………...……………..................................................38
11.1
Optional Accessories
……….………………………………...………...........................39
12 Contact……….………………………………...…………….....................................................40

Rev 20230601 RX - 7000HY/5000HY Page 1 of 41
1.1 Important Safety Instructions
The RX-7000HY/5000HY Hybrid inverter has been designed and tested strictly according to international
safety regulations. Read all safety instructions carefully prior to any work and always observe them
when working with the Hybrid inverter.
Incorrect Operation or Work May Cause:
Injury or death to the operator or third party.
Damage to the inverter and other property
or third party.
Safety Instructions
(a) Do not open the case as risk of electric shock
(b) Maintenance should be carried out by a professional licensed technician
(c) Read this manual before operating the system. Redx is not responsible for failure or loss arising
out of improper operation.
(d) All wiring, installation, commissioning, and other work should be done by a licensed technician
(e) Ensure that the storage unit is not installed or used in the following locations:
● Poorly ventilated room
● Places with inflammable gases or corrosive materials and large amounts of dust
●High or low Environment temperature (above 50°C or below -20°C), or high humidity (greater than 90%)
● In direct sunlight or near heating equipment
● Outdoor
● Do not use anything to cover the inlet and exhaust of the module
In case of fire, use dry powder fire extinguishers instead of liquid fire extinguishers.
•
•
All electrical connections are subject to the local grid safety regulations and the storage system should be
reconnected to the grid under conditions of approval.
1 Safety

Rev 20230601 RX - 7000HY/5000HY Page 2 of 41
Table 1-1 - Warnings
Removal of any protection, incorrect use, incorrect installation, or incorrect
operation may result in death/serious personal injury or device damage.
Transportation, loading and unloading, installation, start-up and maintenance
must be carried out by qualified or trained engineer/technician.
Before maintenance or touching any parts, or installation, make sure that the
energy storage unit is disconnected and wait 5 minutes to ensure that the
internal capacitor is discharged.
Installation must be in full compliance with national and local laws and regulations.
Ensure that the system is positioned correctly and is not allowed to roll sideways
or upside down.
Do not change the internal circuit of the machine without permission.
Before connecting to the grid, system the must be connected to the Ground.
Follow the instructions. Improper operation may cause serious damage.
There is a 4G/WIFI device connecting to the inverter, do not place the system
in an environment where there is no 4G/WIFI signal.
5min
Danger!
Danger!
Warning!
Warning!
Warning!
Warning!
Notice!

Rev 20230601 RX - 7000HY/5000HY Page 3 of 41
The product is not tested to section 5 of AS/NZS 4777.2:2020 and is not to
be used in multiple inverter combinations without additional considerations
by the system designer
The load capacity of the output of the inverter load is as follows:
Inductive load (such as air conditioning, washing machine, motor, etc.).
Single maximum power 3.5kVA, total inductive load maximum power 4.2kVA
(with power grid);
Capacitive load (e.g. computer, switching power supply, etc.).
The maximum power of the total capacitive load is 3.5kVA (without power grid);
The maximum power of the total capacitive load is 4.2KVA (with power grid).
When installing the PV, install a circuit breaker between the PV and the inverter
and between the inverter and the power grid according to local regulations.
When the photovoltaic array is exposed to light, it supplies a DC voltage to
the PCE. To ensure a safe work environment, keep the whole surface of the
photovoltaic panel covered with opaque material to solar radiation before
connecting panel to equipment.
Warning!
Warning!
Warning!

Rev 20230601 RX - 7000HY/5000HY Page 4 of 41
2.1 System Diagram
The RX-7000HY/5000HY is a Hybrid inverter combined with PV and energy storage systems. it
utilizes solar power and battery power to ensure continuous power supply even during a grid
outage, the unused power can also be fed into the power grid. The inverter also provides additional
LV_BUS expansion ports and HV_BUS expansion ports for compatible connections.
Anti-Islanding Protection
The Islanding effect is a special phenomenon when a grid-connected PV system supplies power
to the grid, when the grid has suffered a power loss. Feeding power into a grid during a power loss
is dangerous for maintenance personnel and the public. The RX-7000HY/5000HY inverters provide
Anti-Islanding Protection to prevent the islanding effect.
2 Product Introduction
Figure 2.1.1 - The internal system diagram
RX-7000HY/5000HY

Rev 20230601 RX - 7000HY/5000HY Page 5 of 41
A
BB
B
B
B
B
I
C
D
E
F
H H
G
56V Auxiliary DC input
A
PV Panel
Regular Loads
Smartmeter/CT
Grid
Battery
B
C
D
E
F
G
H
I
Number Name
Circuit Breaker
Backup Loads
RX-7000HY/5000HY Hybrid Inverter
indicates a power cable,indicates a signal cableRed Blue
The explanation is as follows:
Figure 2.1.3 The 7000HY/5000HY application with PV and 56V Auxiliary DC input
Table 2.1.2 - Diagram elements explained
56V Aux
DC
power
source
Autres manuels pour RX Series
4
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Redx Onduleur