Redx RX Series Manuel utilisateur

RX SERIES ALL IN ONE
2505 PU
User Manual
Rev 20220610
RX2505PU
Page 1 of 32

Rev 20220610
RX2505PU
Page 2 of 32

No part of this document can be reproduced in any form or by any means without the prior written
permission of Redx.
All Rights Reserved
Trademarks
and other Redx trademarks used in this manual are owned by Redx
All other trademarks or registered trademarks mentioned in this document are owned by
their respective owners.
Software Licenses
It is prohibited to use data confirmed in firmware or software developed by Redx, in part or in full,
for commercial purposes by any means.
It is prohibited to perform reverse engineering, cracking, or any other operations that compromise
the original program design of the software developed by Redx.
Contact Us
Redx Technology Australia Pty Ltd
Address: U2 /21 Millennium Circuit, Helensvale, Australia 4212
Tel: +61 7 5672 9983
Email: info@redxenergy.com.au
Website: www.redxenergy.com.au
Rev 20220610
RX2505PU
Page 3 of 32

About This Manual
This manual mainly describes the product information, installation, operation, and maintenance guidelines
of the Redx energy storage system. Please read this manual carefully before using this product and store
the manual in a safe place. Redx will not notify the user of any changes to this manual.
This manual applies to the RX-2505PU all in one energy storage integrated system. The system must be
installed by a qualified/licensed technician. The battery chemistry in the all-in-one energy storage
system is lithium iron phosphate. We strongly recommend that installers read this
manual carefully. The manual includes the guidance on product installation, troubleshooting,
communication and other aspects.
Rev 20220610
RX2505PU
Page 4 of 32

1 Safety……….………………………………...……………........................................................6
1.1 Important Safety instructions……….………………………………...….......................... 6
2 Product Introduction……….………………………………...……………...............................8
2.1 System diagram……….………………………………...……………................................8
2.2 Product Information……….……………………………...……….....................................9
2.3 LED Indicator Panel and Switches……….……………………………...........................11
2.4 Name Plate Labelling……….………………………………...………..............................12
2.5 Product benefits……….………………………………...……………................................12
2.6 Scope of Delivery……….………………………………...…………….............................13
2.7 Storage……….………………………………...………………………..............................13
3 Installation……….………………………………...…………….................................................14
3.1 Installation preparation……….………………………………...……… ............................14
3.2 Installation Tools……….………………………………...……………...............................15
4 Installation guide……….………………………………...……………...................................... 16
4.1 System wiring diagram……….………………………………...……… ...........................16
4.2 Installation procedure……….………………………………...………..............................17
4.3 Earth Connection……….………………………………...……………. ............................17
5 Cable Connection……….………………………………...…………….....................................18
5.1 Connect cables to the AC grid side and off-grid side……….………............................18
5.2 CT/METER Connection……….………………………………...……..............................19
5.3 External RS 485 Connection……….………………………………..... ...........................20
6 Operation……….………………………………...………………………....................................21
6.1 Check list before operation……….……………………………….....…..........................21
6.2 Operation……….………………………………...…………….........................................21
6.3 Operation modes……….………………………………...…………….. ..........................22
6.4 Communication……….………………………………...……………................................23
7 RX-2505PU System turn on and turn off……….…………………….....…..........................23
7.1 Turn on RX-2505PU system……….……………………………...….............................23
7.2 Turn off RX-2505PU system……….………………………………...............................23
8 Troubleshooting & Maintenance……….………………………………...…..........................23
8.1 Troubleshooting……….………………………………...…………..................................23
8.2 Maintenance……….………………………………...…………….................................. 26
8.3 Routine Maintenance……….………………………………...………............................ 26
9 Redx iCloud App……….………………………………...……………......................................26
10 Quality Assurance……….………………………………...……………...... ...........................27
11 Appendix……….………………………………...……………................................................27
11.1 Product Specification……….………………………………...………............................27
11.2 Optional accessories……….………………………………...………............................ 29
12 Contact……….………………………………...……………......................... ..........................30
Contents
Rev 20220530
RX2505PU
Page 5 of 35
Rev 20220610
RX2505PU
Page 5 of 32

1 Safety
1.1 Important Safety instructions
The Energy storage system has been designed and tested strictly according to international safety
regulations. Read all safety instructions carefully prior to any work and always observe them when working
with the energy storage system.
Incorrect Operation or Work may cause:
Injury or death to the operator or third party; or
Damage to the inverter and other property or third party.
Safety Instructions
a) Do not open the case as risk of electric shock is present
b) Maintenance should be carried out by a professional licensed technician
c) Read this manual before operating the system. Redx is not responsible for failure or loss
arising out of improper operation.
d) All wiring, installation, commissioning, and other work should be done by a licensed technician
e) Ensure that the storage unit is not installed or used in the following locations
Poorly ventilated room
Places with inflammable gases or corrosive materials and large amounts of dust
High or low Environment temperature (above 50°C or below 0°C), or high humidity (greater
than 90%)
In direct sunlight or near heating equipment
Outdoors (indoor installation only)
Do not use anything to cover the inlet and exhaust of the module
In case of fire, use dry powder fire extinguishers instead of liquid fire extinguishers
All electrical connections are subject to the local grid safety regulations and the storage system should be
reconnected to the grid under conditions of approval.
•
•
•
•
•
•
•
•
Rev 20220610
RX2505PU
Page 6 of 32

Removal of any protection, incorrect use, incorrect installation, or incorrect
operation may result in death/serious personal injury or device damage.
Transportation, loading and unloading, installation, start-up and maintenance
must be carried out by qualified or trained engineer/technician.
Before maintenance or touching any parts, or installation, make sure that the
energy storage unit is disconnected and wait 60 seconds to ensure that the
internal capacitor is discharged.
Do not connect the N of grid to the N of UPS output, Do not connect the grid
cable to the UPS output, otherwise it may cause serious damage to the system
and load.
Installation must be in full compliance with national and local laws and regulations.
Ensure that the system is positioned correctly and is not allowed to roll sideways
or upside down.
Do not change the internal circuit of the machine without permission.
Before connecting to the grid, system the must be connected to the Ground.
Follow the instructions. Improper operation may cause serious damage.
There is a 4G/WIFI device inside the system, do not place the system in an
environment where there is no 4G/WIFI signal.
60S
Danger!
Danger!
Danger!
Warning!
Warning!
Warning!
Warning!
Notice
Table 1-1 - Warnings
Rev 20220610
RX2505PU
Page 7 of 32

2 Product Introduction
2.1 System diagram
The RX-2505PU system uses the grid and battery to ensure the continuous power supply of important
loads. The system allows users to store the energy from grid into the battery. It can also provide backup
power during the power outage
Figure 2-1 shows the application of the RX-2505PU all-in-one uninterruptible power system. RX-2505PU
contains inverter and battery storage modules. It is important to keep the installation environment well
ventilated and take necessary measures to control the ambient temperature to avoid the risk of explosion
caused by excessive battery temperature
Product should not be installed in multiple phase combinations
The load capacity of the output of the inverter is as follows:
Inductive load (such as air conditioning, washing machine, motor, etc.) :
Single maximum power 1.5kVA, total inductive load maximum power 2.5kVA
(with grid power);
Capacitive load (e.g. computer, switching power supply, etc.) :
The maximum power of the total capacitive load is1.5kVA (without grid power);
The maximum power of the total capacitive load is 2.5KVA(with grid power).
Warning!
Warning!
Solar
Switchboard
Back-up
appliances
Main switch Utility meter Grid
Wind
Cloud monitoring
and control
Table 1-2 - Warnings continued
Figure 2-1 - System block diagram
Rev 20220610
RX2505PU
Page 8 of 32

2.2 Product Information
2.2.1 Appearance and dimensions
NameItems
1Main power switch
Battery air circuit-breaker
DC1 input
DC2 input
AC-ON Indicator light
DC Indicator light
Grid Indicator light
Charge Indicator light
Battery status
Nameplate
Datalogger QR code
USB(RS485)
230AC IN
230AC OUT
230AC OUT
Mounting bracket
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
16
5
91
2
3 4
10
13
12
14 15
11
6
7
8
Figure 2-2 - Battery system components
Table 2-1 - Battery components details
Rev 20220610
RX2505PU
Page 9 of 32

2.2.2 Dimension and weight
A(mm)
145
B(mm)
600
C(mm)
900
Weight
75KG
AB
C
Figure 2-3 - Battery system components
Table 2-2 - Battery system dimensions details
Rev 20220610
RX2505PU
Page 10 of 32
Autres manuels pour RX Series
4
Ce manuel convient aux modèles suivants
1
Table des matières