Red Sea ReefWave 25 Manuel utilisateur

ENG
User Manual


User Manual
Silent - Smart - Powerful

Red Sea ReefWave®
4
Contents
Introduction...........................................................................5
Safety ...................................................................................6
ReefBeat app........................................................................7
ReefWave control options...................................................8
Installation.........................................................................10
ReefWave Controller..........................................................12
Using ReefWave without ReefBeat..................................13
ReefWave with ReefBeat - Setting up.............................13
Settings...............................................................................16
Operation with ReefBeat..................................................18
Device Manager.................................................................18
Maintenance......................................................................21
Troubleshooting..................................................................22
Spare Parts list....................................................................24
Warranty..............................................................................26

Red Sea ReefWave®
5
Introduction
Congratulations on your purchase of Red Sea’s ReefWave®.
Developed specifically for Red Sea, the ReefWave pumps feature the
unique, patented, Maxspect cross-flow technology and provides a Reef-
Spec water motion that’s perfect for corals wherever they are placed in
your aquarium. The combination of an advanced, smooth running and
energy efficient sine-wave motor drive, vibration damping mounts and
dual bearings on all models make ReefWave an especially quiet pulsing
wave pump.
ReefWave is part of Red Sea’s suite of smart devices that can be
operated via Wi-Fi by Red Sea’s ReefBeat®app which needs to be
installed on a smart mobile device with internet connectivity. In addition,
the ReefWave can also be operated directly from its on-board controller.
ReefBeat provides a wide range of easy-to-use functions including
notifications if there is a loss of communication with your ReefWave –
such as in the case of power failure.
ReefBeat®is under constant development and over time will
include additional connected devices as well as additional aquarium
management tools.
Welcome to Red Sea’s smart reef-keeping.
Sincerely,
The Red Sea Team
Specifications ReefWave®25 ReefWave®45
Max Flow Rate 7,500 LPH (1980 GPH) 15,000 LPH (3960 GPH)
Power
Consumption 4w - 25w 8w - 45w
Dimension 23cm (9") L x 7cm
(2.8") W x 4cm (1.6") H
31.5cm (12.4") L x 8cm
(3.2") W x 5cm (2") H
Recommended
Aquarium size
45cm – 120cm
(1.5-4 ft)
60cm – 200cm
(2-6 ft)
Maximum glass
thickness 15mm (5
/
8") 20mm (3
/
4")
Cable Length 3M (10 ft) 3M (10 ft)

Red Sea ReefWave®
6
Safety
PLEASE READ AND FOLLOW ALL SAFETY INSTRUCTIONS
THIS DEVICE IS INTENDED FOR INDOOR USE ONLY.
DANGER: To avoid possible electric shock, special care should be taken
when handling a wet aquarium. For each of the following
situations, do not attempt repairs yourself; return the appliance
to an authorized service facility for service or discard the
appliance.
WARNING: To guard against injury, basic safety precautions should be
observed, including the following:
Do not operate any appliance if it has a damaged cord or plug, if it is
malfunctioning, or if it is dropped or damaged in any manner.
To avoid the possibility of the appliance, plug or receptacle getting wet,
position the aquarium stand and tank to one side of a wall-mounted
receptacle to prevent water from dripping onto the receptacle or plug.
You should create a "drip loop" (see Figure 1) for each cord connecting an
aquarium appliance to a receptacle. The "drip loop" is that part of the cord
below the level of the receptacle, or the connector. Use an extension cord,
if necessary, to prevent water traveling along the cord and coming into
contact with the receptacle. If
the plug or receptacle does get
wet, DO NOT unplug the cord.
Disconnect the fuse or circuit
breaker that supplies power to
the appliance. Then unplug the
device and examine for presence
of water in the receptacle.
Close supervision is necessary when any appliance is used by or near
children.
To avoid injury, do not contact moving parts.
Always unplug an appliance from an outlet when not in use, before
putting on or taking off parts, and before cleaning. Never pull the cord
itself to remove the plug from the outlet. Grasp the plug and pull to
disconnect.
Do not use an appliance for anything other than its intended use.
The use of attachments not recommended or sold by the appliance
manufacturer may cause unsafe conditions.
Do not install or store the appliance where it will be exposed to the
weather or to temperatures below freezing point.
Make sure an appliance mounted on a tank is securely installed before
operating it.
Read and observe all the important notices on the appliance.
Note: A cord rated for less amperes or watts than the appliance rating
may overheat. Care should be taken to arrange the cord so that
it cannot be tripped over or pulled accidentally.
ReefWave pump mounts use STRONG MAGNETIC FIELDS
Strong magnets can cause personal injury.
Keep out or the reach of children.
Persons with medical implants should maintain a
distance of 30cm/12”

Red Sea ReefWave®
7
Introduction to the ReefBeat app
All of Red Sea’s connected devices can be operated via the ReefBeat
app installed on an Android or iOS smart mobile device (SMD) with an
internet connection. See the full list of supported mobile phones/tablets
on our website.
Through your personal user account on the cloud, ReefBeat enables
you to set up and manage any number of aquariums and add multiple
devices to each of them.
For full functionality, each ReefWave must have a permanent connection
to the internet through your home Wi-Fi network. In this mode of
operation, you will be able to see the current status of your ReefWave
units, change the settings or receive notications on your SMD whenever
you have access to the internet.
The ReefBeat homepage will show you the current status of all of your
connected devices, and links you directly to the Settings Dashboard for
each group or for individual units.
You can install the ReefBeat on multiple SMDs by entering the same user
account details. All SMDs will have the same rights for operating and
changing all of the settings. You should keep this in mind before giving
your user details to any 3rd party.
In the event that you do not have a home network or your home network
does not have an active internet connection, you will only be able to
operate the ReefWave from the controller with limited functionality. More
information about operating the ReefWave in “Controller Mode” is provided
below.
ReefBeat is constantly under development. For the most up to date
operation instructions, view or download the latest user guide from the
Red Sea website at www.redseash.com
If this is your rst Red Sea connected device, it is recommended that
you complete the physical installation of your ReefWave units before
installing the ReefBeat app.

Red Sea ReefWave®
8
Local Controller Functions
Regular Flow
Pump provides a constant flow of water at the intensity you set in
forward or reverse direction.
Uniform Wave
Pump pulses at a uniform rate of 5 seconds between the maximum
intensity in the forward or reverse direction you set and a default
minimum 10% intensity.
Step Wave
Pump pulses at a uniform rate of 5 seconds at a constantly
changing intensity in steps of 10% from the minimum of 20% to
the maximum intensity you set in the forward or reverse direction.
Random Wave
Pump pulses at a randomly varying rate and at a randomly
changing intensity up to the maximum intensity you set in the
forward or reverse direction.
Alternate Wave
Pump will alternate between a uniform wave in the forward
and reverse directions every 5 minutes. User sets the maximum
intensity for both directions.
ReefBeat Mode
In the event that a ReefWave controller has been programmed
by ReefBeat, selecting this mode will implement the last known
24-hour wave schedule even when not connected to the ReefBeat
App.
Feed Mode
Pump will stop for 30 minutes and will automatically resume the
currently selected wave.
Pause/Play
Stop and start the pump on demand as required for pump or tank
maintenance.

Red Sea ReefWave®
9
ReefBeat Connected Functions
ReefBeat Schedule
User defined 24 hour schedule of up to 10 time slots per day. Each
time slot will implement a user defined wave in the forward, reverse
of alternating direction. There is also a “no wave” option for periods
of no flow.
ReefBeat Wave Library
Multiple customized versions of each of the waves types can be
saved in the wave library for implementation in the daily schedule.
Groups
Up to 3 pumps can be grouped together and run a common schedule.
Regular Flow
Pump provides a constant flow of water at the intensity you set in
forward or reverse direction.
Uniform Wave
Pump pulses at a user definable uniform pulse rate between the
maximum intensity in the forward or reverse direction you set and a
default minimum 10% intensity. Grouped pumps can be run in sync or
anti-sync.
Step Wave
Pump pulses at a user definable uniform pulse rate with intensity
increasing in user definable number of equal steps from the minimum
of 20% to the maximum intensity you set in the forward or reverse
direction.
Random Wave
Pump provides a constant flow of water at the maximum intensity you
set in forward or reverse direction.
Surface Wave
Pump pulses at a user definable uniform pulse rate set in 1/10 of
a second to create a standing wave pattern on the water surface.
Grouped pumps can be run in sync or anti-sync.
Preview
Test wave settings before saving and including in the Schedule.
On/Off
Stop and start a specific pump on demand for individual pump
maintenance.
ReefBeat Feed Mode
All selected ReefBeat connected devices will be stopped for a user
defined period and thereafter will automatically resume the schedule.
ReefBeat Maintenance Mode
All selected ReefBeat connected devices will be stopped until the
Maintenance mode is disabled and wave schedule will be resumed.
ReefBeat Emergency Shut-down
All selected ReefBeat connected devices will be stopped until the
Emergency shut-down is disabled and wave schedule will be resumed.
Notifications
A notification will be sent to your SMD whenever internet connection
to the ReefWave is lost. Could be due to a power or internet outage,
router failure or a fault with a specific device.

Red Sea ReefWave®
10
Installation
WARNING: Running the pumps outside of the water will damage
the bearings and impellor shaft causing noisy operation and a
shortened life for these wear parts!
Pump
The ReefWave pumps can be mounted in the horizontal or vertical
orientation.
Each of the 2 impellor cages can be rotated 360 degrees within the
mounting bracket to adjust the direction of the flow appropriately for
your reefscape. Initially set the A and B markings on the cage to be in
line with the ReefWave logo.
In this position the flow will be approximately perpendicular to the
magnet. The impellors and impellor cages on either side of the pump
motor are slightly different and therefore the rubber parts for each side
are color coded Red and Green to ensure that parts are reassembled
correctly after maintenance.
The impellors of the pumps can rotate both in the forward and reverse
direction however the flow in the forward direction is about 3 times
stronger than the flow in the reverse direction.
When mounting the pumps in the horizontal direction make sure that
the cable is on the top side of the pump. Mount the pumps at least
5cm/2” below the water surface to prevent vortex formation (sucking of
air from the water surface.
Mount the pumps in a location where there is easy access for
adjustment of flow direction and removal for periodic maintenance.
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Red Sea Pompe à eau
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur