RCA RSWL1 Manuel utilisateur

Installation Guide
RSWL1 Install 02
English instructions..............1
Instructions en français...... 17
Instrucciones en español .. 33

2
Welcome!
The RCA Smart Laundry Water Shut-Off System puts your mind at ease by protecting your home or business against
water damage. Simply install the control unit, smart module, and shut-off valves included in this package, and you’re set
to stop a disaster before it happens! This installation guide takes you through the steps to get set up.
What’s in the package?
Control unit
with connection wires attached
Mounting template for the control unit
Water sensor for the control unit
Hardware bag
(1) Double-sided tape for control unit
(1) Double-sided tape for smart module
(4) Drywall screws with anchors
(#6 x 1-1/4” Phillips pan-head)
(4) Masonry screws (3/16” at-head)
(4) Wire ties
(3) Wire ties with double-sided tape
(2) Rubber o-rings for valves
(2) Automatic shut-off valves
one red (HOT) and one blue (COLD)
Smart module
with connection wires attached
(optional, see page 8 for information)
Power adapter for the smart module
3-outlet AC wall tap to provide an additional
electrical outlet if needed

3
A. Find your washer’s shut-off valves
Step 1: Mount the control unit and smart module to the wall
Separate hot and cold shut-off valves are usually located behind or next to your
washer, with hoses leading to your washer.
Washer
Shut-off
valve
B. Find the best place to mount the control unit and smart module
The control unit needs to be close enough to the shut-off valves and oor for the
sensor wire (6ft) and control lead wires (5ft) to reach.
The smart module should be between the control unit and the shut-off valves. It
also needs to be close to a power outlet.
Less than 5ft
Less than 6ft
Control
unit
Floor
Shut-off
valves
Power
outlet
Smart module
IMPORTANT: The smart module needs a strong signal from your WiFi router to work properly.
Test the strength of your WiFi network’s signal where you plan to mount the smart module—make
sure your phone is on the WiFi network you want to use, then look at the WiFi signal meter on your
phone’s screen. Make sure you’re getting at least 50% signal strength where you plan to install. If not,
try moving your WiFi router closer (or installing a WiFi signal booster close to the installation).

4
Step 1 (continued)
C. Write down the MAC address from the smart module
Smart
module,
back and side
The back and side of the smart module list its MAC address. You’ll need this to
add the module to the App and your WiFi network later on, so you should nd
it and write it down now, before you mount the smart module to the wall.
Smart Module MAC Address:________________________
D. Mount the control unit and smart module to your wall
The control unit and smart module offer three options for mounting to the wall.
Option 1: Double-sided tape (included, not for masonry applications)
1. Clean the wall where you want to mount the control unit and/or smart module.
2. Apply the double-sided sticky tape to the back of the control unit and/or smart module.
3. Peel off the exposed side of the sticky tape.
4. Press the control unit and/or smart module rmly against the wall where you want to mount it.
Rating LABEL
2018/03/27
MODI-IOT
67630551460G A
0.1
YangZhiQiang
条码读码为: 70F8E7262881
此号码为16进制,每张标签之间需跳一码,
即第一张号码为70F8E7262881,则第二
张号码为70F8E7262883,.....此次流水号为
此次流水号为
GMA252V13F0001~GMA252V13F0100
70F8E7262881~70F8E7262947,共100张.
MAC NUMBER
MAC
SN: GMA252V13F0001
: 70F8E7262881
SMART MODULE
MADE IN CHINA
CAN ICES-3(B)/NMB-3(B)
FCC ID: VIXMOD1
IC: 21578-MOD1
MODEL: MOD1
INPUT: 12V 1A
30.0mm
36.0mm
条码读码为:
GMA252V13F0001
Serial number
F:
GMA25:Model code(MOD1-IOT)Assigned by AEC
V: Manufactured year(V=2018,skip I,O,S,Z)
13: Manufactured week
2
TO: 采购
2018.03.27

5
Option 2: Drywall screws with anchors (included)
1. Place the mounting template(s) on the wall where you want to mount the
control unit and/or smart module. IMPORTANT: Make sure there are no
electrical wires where you plan to drill.
2. Draw x’s on the wall where indicated by the mounting template(s). Drill a
9/32” pilot hole at each x for the anchors.
3. Install the dry-wall anchors at the marked location with a #2 Phillips
screwdriver
4. Mount the drywall screws in the anchors. Leave some space between the
screw heads and the wall so that you can mount the control unit and/or
smart module on the screws.
5. Mount the control unit and/or smart module on the screws.
Option 3: Masonry screws (included)
1. Place the mounting template(s) on the wall where you want to mount the
control unit and/or smart module.
2. Draw x’s on the wall where indicated by the mounting template(s).
3. Use a 5/32” masonry drill bit to drill pilot holes where you marked the x’s.
The holes should be about 1-1/2” deep.
4. Mount the masonry screws where you drilled the pilot holes. Leave some
space between the screw heads and the wall so that you can mount the
control unit and/or smart module on the screws.
5. Mount the control unit and/or smart module on the screws.
45mm(1.77")
72mm(2.83")
MOUNTING TEMPLATE
USE FOR FLAT
WALL MOUNT ONLY
FOR THE CONTROL UNIT
Control Unit
Mounting Template
Drywall
screws
Masonry
screws
MOUNTING TEMPLATE
USE FOR FLAT
WALL MOUNT ONLY
( 2 ")
( 3.45")
( 2.36")
50.8mm
87.5mm
60.0mm
Smart Module
Mounting Template

6
2. Install the auto shut-off valves
A. Turn off your washer’s shut-off valves
B. Place a bucket and towel under the hoses
When the shut-off valves are in the on position, they’re pointing toward the hose.
Turn each valve 90-degrees counter-clockwise to turn it off.
Shut-off valves
On Off
There is probably water inside them that will leak when you take them off.
C. Take the hoses off the washer shut-off valves
IMPORTANT: Keep track of which hose went on the hot vs. cold valve.

7
D. Install the automatic shut-off valves on the washer shut-off valves
2. Match the red automatic shut-off
valve (HOT) to the red valve and
the blue (COLD) to the blue valve.
1. Remove the plastic protectors
from both ends of each
automatic shut-off valve.
Make sure the rubber o-rings
are seated properly (at) inside
each shut-off valve hose tting.
3. Screw each hose tting onto the
automatic shut-off valves.
Hand-tighten the collar of the
tting onto the washer shut-off
valve. Keep the valve at a 4 o’clock
position until you’re ready to give
the nal tightening, then turn the
entire valve assembly to tighten
and straighten.
E. Screw the hoses onto each automatic shut-off valve
Make sure each laundry hose still has its o-ring inside the hose tting. If it
doesn’t, use one of the extra o-rings provided in this package (if it already has
one, don’t add another).
Make sure to match each hose to the shut-off valve it was on before. Then screw
each hose on tight by hand (use a channel lock or pliers for the last quarter-
turn).
Shut-off
valve hose
tting
O-ring
seated at

8
A. Connect the lead from one shut-off valve to a control box lead.
Step 3: Connect the valves, control unit, and smart module
Control
Box
Shut-Off Valves
Smart
Module
B. Connect the second control box lead to the rst lead from the smart module.
Control
Box
Shut-Off Valves
Smart
Module
How to connect leads
1. Line up the round and square plugs
on each control box lead to the
corresponding round and square
holes on the lead from the auto shut-
off boxes.
2. Snap both pairs of leads into place.
NOTE: The Smart Module is Optional
The Smart Module is what allows the laundry shut-
off system to send notications to your phone, but
the system can be used without it as well. Simply
connect the second control box lead directly to the
second shut-off valve, as
shown here. Then skip to
step E on page 10.
Control
Box
Shut-Off Valves

9
C. Connect the middle lead from the smart module to the other shut-off valve.
Control
Box
Shut-Off Valves
Smart
Module
D. Connect the third cord from the smart module to the DC In jack on the control
box.
Control
Box
Shut-Off Valves
Smart
Module
DC In
Use the included wire ties to gather the wires and
stick them to the wall so that they’re out of the way.
Clean the wall rst. Then stick the back of the wire
tie to the wall. Use the other wire tie closer to the
control box to gather the wires there as well.

10
F. Plug in the smart module.
1. Plug the smart module’s power adapter into the jack on the side of the smart module.
IMPORTANT: If you’re using the laundry shut-off system without the smart module, plug the power adapter directly into
the DC In jack on the control unit.
2. Plug the other end of the power adapter into an available power outlet.
If both power outlets are in use (by the washer and dryer, for example), use the included 3-outlet power wall tap to
provide additional outlets.
When the smart module and control unit rst power on, the yellow indicator light on the front panel of the control unit
ashes—the auto shut off valve system is arming and opening valves. When the green indicator light comes on, the
system is ready to use.
E. Place the leak sensor on the oor beneath the washer shutoff valves.
Agua detectada
Make sure the sensor is sitting at on the oor directly beneath the shutoff valves.
(Do not place it inside the washer oor tray if you have one.)
Table des matières
Langues :
Autres manuels RCA Système de sécurité
Manuels Système de sécurité populaires d'autres marques

EDM
EDM Solution 6+6 Wireless-AE Manuel utilisateur

Highway Safety Group
Highway Safety Group EA401 Manuel utilisateur

Siren
Siren LED GSM Manuel utilisateur

Detection Systems
Detection Systems 7090i Instructions de montage

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuel utilisateur

Siemens
Siemens FDM273 Manuel utilisateur