Raytec VARIO2 series Manuel utilisateur

1www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
POE
Installation Guide
Contents
Page 2 Box Contents / Safety Information / Product Introduction
Page 4 Installation Guide –Short Guide
Page 5 Factory Defaults / Complete Set Up and Installlation
Page 10 LED Status Indicators –Feedback System
Page 10 Programming Mode and Operating Mode
Page 12 VARIO Remote Controller (VRC)
Page 14 PIN Function Guide
Page 16 Manual Control Push Buttons
Page 22 Disabling Manual Buttons
Page 23 Power Up Functionality ; Re-Set Options
Page 24 Re-enabling Manual Buttons and Remote Controller
Page 25 Standard Bracketry
Page 26 Specifications Table
Page 28 Troubleshooting
Page 32 Quick reference tables for Manual Button Control and
Remote Controller guide for PIN Set and Manual Button
Disable/ Enable

2www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Box Contents
VARIO2 POE Illuminator fitted with 35° beam angle ILS
and 60° beam angle ILS (ILS: Interchangeable Lens System)
Accessories (Optional) :VARIO Remote Control for additional Programming;
80˚ beam and 120˚ beam angle ILS;
Additional Raytec Bracketry
Safety Information
Eye Safety: Infra-Red Variants (850nm and 940nm)
Caution –IR emitted from this product EN62471 Risk Group 2
Do not stare at the illuminator. Avoid exposure or use
appropriate shielding / eye protection. Risk Group 2 for
cornea / lens infrared hazard. hazard distance is 1500mm.
Max IR EHV (Exposure Hazard Value) : 69% of Risk Group 2
Limit at 200mm from the illuminator.
Eye Safety: White Light Variants
Caution –EN62471 Risk Group 2 Classification - Possible
hazardous optical radiation emitted from this product. May
be harmful to eyes, do not stare at the lamp. Hazard
distance is 1500mm. Max WL EHV (Exposure Hazard Value) :
68% of Risk Group 2 Limit at 200mm from the lamp.
Product Introduction
VARIO2 PoE is an Illuminator designed to be powered by POE
It is available in Standard and Premium variants
For Standard and Premium Variants :
The illuminator has a photocell for automatic day/night switching and also
benefits from Raytec’s interchangeable lens system so that the correct
angle of illumination can always be achieved easily.

3www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
The illuminator has a CAT5 cable for POE connection and is supplied with a
waterproof Cat 5 connector.
For Premium Variants Only :
Auxiliary cable if low voltage 24V DC operation is preferred.
External Input (to act as a telemetry, trigger input, volt free or TTL) and an
External Output (to act as a Photocell Following Contact - volt free output)
Photocell
Auxiliary Cable (Premium Variants only)
Optional 24V DC power input –red (+ve) &
black (-ve)
External Input, volt free or TTL –orange (TTL
+ve) & purple (TTL GND)
External Output, volt free –yellow & white
CAT 5 Cable
for PoE
Interchangeable
Lensing
PoE Detection
Resistance Selection
Switch
Please note:
base plate has
been removed for
illustrative purposes.
Please note:
Waterproof connector
is supplied loose –
and is shown fitted
for illustrative
purposes

4www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Installation Guide –Short Guide :
STEP 1: Safety Information (Pg. 2)
STEP 2: Physical Installation (Pg. 5)
Adjust interchangeable lens if required.
Fix to wall, pole or camera unit using U bracket provided or other Raytec
bracketry.
IMPORTANT:
Ensure illuminator is rated to provide required viewing distances and select
correct angle
Ensure illuminator is orientated in the correct direction
STEP 3: Wiring (Pg. 6)
For PoE, use standard CAT 5 or better. For all 8 sized products, check the PoE
detection resistance of the illuminator is compatible with your PoE
equipment (24.9KΩ is factory default).
Premium Variants : For low voltage (non-PoE) apply 24V DC to red and
black cores of auxiliary cable. Connect external inputs and external output
wires as required.
IMPORTANT:
Ensure PoE equipment or 24V PSU are suitably rated
For 8 sized products check PoE detection resistance is set correctly
Ensure Cat 5 cable and auxiliary cable are correctly terminated and
waterproofed after installation
If not using auxiliary cable, it must still be suitably terminated and
waterproofed
Step 4 : Interchangeable Lenses: Changing the Angle (Pg. 8)
Step 5 : Configuration - Programming and Settings (Pg. 9)
Step 6 : Security (Optional PIN protection) (Pg. 9)

5www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Factory Default Set-Up
35˚ Beam Angle; Max 100% Power
Photocell sensitivity –MID (Illuminator comes on when dark)
Telemetry Input –closed (Premium Variants Only)
Status LEDs –ON; No PIN Set; Manual Push Button Control Enabled
Programming function will auto-disable after 7 Days - See Mode Power Up
and Time Out Functionality –Pg 23
Vario2 POE : Complete Set Up and Installation
STEP 1: Safety Information (Pg. 2)
Step 2 : Physical Installation
VARIO2 PoE is delivered as standard with bracket at the bottom of the unit.
This can be moved to top of the unit if required.

6www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Attach illuminator to wall, housing or pole using U-bracket provided or
dedicated Raytec bracketry.
Step 3 : Wiring
The illuminator is supplied with a terminated CAT5 cable with a waterproof
Ethernet connector (supplied loose i.e. not fitted). Premium variants also
have an auxiliary multi-core cable fitted.
Power via PoE
Connect an Ethernet cable (category 5 or better) using the T-568B wiring
standard between the Power Sourcing Equipment (PSE) and the illuminator.
Ensure that the PSE is sufficiently rated to power the VARIO2 PoE device as
follows:
Model (Standard and Premium)
PoE Requirement
VAR2-POE-w2-1, i2-1, i2-1-C
IEEE 802.3af (HP PoE) ≤12.95W
VAR2-POE-w4-1, i4-1, i4-1-C, i6-1
IEEE 802.3at (HP PoE) ≤25.5W
VAR2-POE-w8-1, i8-1, i8-1-C
4-pair PoE ≤51W
The maximum Ethernet cable length is 100m (328’) without boosting the
power.
Ensure you make a waterproof connection to the RJ45 as shown below.
Ensure the connector is waterproof and sealed after the connection is
made.
To illuminator RJ45-RJ45 connector To PSE
Please Note :
For Premium Models, illuminator can also be powered by 24V DC

7www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
PoE Detection
Resistance Selection Switch
There is a switch on the VAR2-PoE-w8-1, i8-1 and i8-1-C illuminators which
can be used to change the PoE detection resistance of the illuminator
(24.9KΩ is the factory default setting).
Turn the power to the illuminator OFF, remove the baseplate and access the
switch as shown.
The majority of PSE equipment requires a detection resistance of 24.9KΩ to
establish a PoE link. Some models of PSE equipment require a 12.5KΩ
detection resistance. Check with your supplier of PSE equipment.
For 24.9 KΩ, slide switch to the LEFT (factory default – as shown). For 12.5 KΩ,
slide switch to the RIGHT.
Power from 24V DC (Premium Variants Only)
If using low voltage power, connect 24V DC to the red (+ve) and black (-ve)
cables of the auxiliary cable.
For Premium variants : connect external input trigger and external output as
required –see table and description below:
Colour
Description
Wire Gauge
(AWG)
Orange
External Input -Volt free or TTL +ve
22
Purple
External Input -Volt free or TTL GND
22
Yellow
External Output –Volt free
22
White
External Output - Volt free
22
Detection Resistance Selection
Switch

8www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
WARNING:To maintain the IP rating of the product the multicore auxiliary
cable must be waterproofed and terminated appropriately even if it is not in
use.
Telemetry Input (Orange & Purple)
As default the telemetry input will be wired together so that the
unit turns on/off automatically via the photocell. If required to be
activated by PIR or alarm system, connect to appropriate, volt-
free or TTL input. Volt free input/dry contact: Non polarity
sensitive, short circuit = light on
TTL input: Orange = TTL +ve, Purple = TTL –ve (GND) 0V = Light on,
3V = Light off
Photocell following output (White & Yellow)
Volt free output - normally open (day) to normally closed (night).
Connect direct to camera if required to control switchover of
day/night cameras.
Step 4 : Interchangeable Lenses: Changing the Angle
Step 1
Unscrew
baseplate
Step 2
Remove
baseplate
Step 3
Remove /
Replace diffuser
lens
Step 4
Replace
baseplate
& tighten

9www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
The illuminator is delivered with a 35 Degree beam angle. To alter to 10
Degrees, remove the baseplate from the bottom of the product (Using a
2.5mm allen/hex key ) and remove the existing lens and then re-attach the
baseplate securely ensuring the gasket is correctly located. With no lens
insert the product produces a 10 Degree beam angle.
To alter to any other angle, remove the existing lens and insert the required
lens which will have its angle indicated on it. Ensure the baseplate is securely
re-attached to maintain waterproof integrity of the product.
The angles available as standard are: 10°x10° (No lens / diffuser in place),
35°x10° and 60°x25°. Other angles are available to order: 80°x30° and
120°x50°.
All ILS lenses will be clearly marked with the angle which they will produce
when inserted into VARIO2 POE.
Please handle ILS lenses with care –and do not touch optical film.
Only 1 ILS lens can be inserted into the product at any time. The product
cannot accommodate multiple ILS lenses at the same time.
We would recommend that power is turned off when replacing ILS lenses.
Step 5 : Configuration - Programming and Settings
Programme using optional VARIO Remote Controller (VRC) or the
manual control push buttons. –See Detailed Section
Step 6 : Security (Optional PIN protection)
Set PIN (If Required) (Can only be done with the optional VARIO Remote
Controller (VRC) –See Detailed Section
Important Note : Ensure base plate is securely located, the gasket is
correctly located and the screws correctly fastened to ensure and
maintain IP66 rating of the product

10 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
LED Status Indicators- Feedback system
There are two tri-coloured LEDs visible on the base of the VARIO2
POE illuminator. The two LEDs provide important operating and
status information.
The status information provided by each of these LEDs differs
depending on which of the two operating modes the VARIO2
POE illuminator is in: (A) Programming OR (B) Operating
The LED Indicators also give feedback if you are using the
Remote, PIN Function or Manual Control Modes –Please see
Pages 14 to 22 for detail on the LED status indicator feedback for
these functions
(LHS) (RHS)
Programming Mode and Operating Mode
Factory Default: On initial power-up, the illuminator is in
Programming Mode.
On powering up the illuminator, it automatically enters
programming mode to allow the user to adjust set-up and
operation. The programming mode automatically times out after
7 Days or until the user actively disables the programming mode
and changes to Operating Mode. However, if you use the
manual push buttons at all during this time, the illuminator will
automatically enter operating mode 30 minutes after the last
button press.
Base Plate Pictured ON