INSTALLATION AND OPERATING INSTRUCTIONS
MODEL UCS3
(Please save for future reference.)
INTRODUCTION
Your Drinking Water System 3 uses a unique 3 stage filtering process to provide safer,
better tasting water in your home. It can be used on any water supply and is not limited to
municipally treated sources. The water first passes through an Activated Carbon Cartridge
(CF2) which reduces objectionable tastes, odours, colours and chlorine. This cartridge should
be replaced every 4 months*.
Next the water passes through a (LR1) Carbon Cartridge that reduces Lead, Volitile Organic
Compounds (VOC's) >95%, THM's (Trihalomethanes) >95%, chlorine and unpleasant taste/
odour 99%. It also filters sediment as fine as 1.0 micron (nominal). The LR1 is a disposable
cartridge, which should be replaced every 6 months*.
Finally the water passes through a self-disinfecting, silver impregnated Ceramic Cartridge
(1M) which traps and kills harmful bacteria >99.99999%, traps cysts & protozoa >99.9% and
filters particulates as small as 0.3 micron (absolute). This cartridge is cleanable and reusable.
The flow rate will gradually slow during use as contaminants build up on the ceramic surface.
The flow is restored by scrubbing the surface of the cartridge as required using the abrasive
cleaning pad (811-0) enclosed. The 1M cartridge should be replaced after 1 year or if the car-
tridge gauge (703-4) can be passed over the width of the ceramic*.
*Note: Cartridge life is directly dependant on water conditions and volume of water filtered.
Excessive sediment may cause more frequent replacement.
Warning: Individuals requiring water of specific microbiological purity should follow the advice
of their doctor or local health unit.
OPERATING SPECIFICATIONS
Maximum Pressure - 100 psi / 6.9 Bar. If water pressure surges, or will at any time exceed the 100 psi maximum, a pres-
sure regulator and/or water hammer arrestor must be installed before the filter to prevent damage to the unit due to presures
exceeding maximum rating of the unit. Recommended regulator setting is 75 psi or less.
Maximum Temperature - 100°F / 38°C.
Cartridge Life - CF2 and LR1 - 375 gal / 1491 L or 4 months Rated Service Flow - 0.75 gpm / 2.8 Lpm
- 1M - 1000 US gal (3785L) or 1 year
INSTALLATION (Read carefully before proceeding and keep instructions for future use.)
This unit comes with cartridges, faucet assembly and fittings to install the unit below the counter
to copper or CPVC rigid plastic pipe.
Unpacking the Unit
Remove each sump (520) by turning it 1/8 turn to left, then pulling away from head assembly
(2526-0). Remove CF2 and LR1 cartridge by twisting and gently pulling away from head boss.
Place CF2, LR1 and 1M Ceramic cartridge (packed separately) aside in a safe place until final
assembly. CAUTION: YOUR CERAMIC CARTRIDGE IS FRAGILE AND SHOULD BE TREATED
LIKE CHINAWARE.
Mounting the Faucet
Faucet may be installed in hole in sink if available or in counter top. Note: The faucet may also
be installed in the sink sprayer hole if available.
1. Position faucet on counter top beside sink in desired position. Ensure that swivel
spout will extend over sink and that there is room under the counter for faucet shank and to
tighten nuts.
2. Mark the location and drill a ½” hole. Protect your counter top by applying a layer of masking tape and use a sharp drill.
3. (See Fig. 1). Insert faucet shank through escutcheon plate (1040-9) and escutcheon washer (1040-10), and then through
counter top. Install plastic locating washer(1040-12), lock washer (1040-13) and locking nut (1040-14). Tighten locking
nut securely while someone holds the faucet body so it does not turn. Place adaptor washer (1040-16) inside 3/8” adapter
(1040-15) and tighten adaptor securely on to the faucet shank with a wrench. Caution: Do not use any thread sealant or tape
on the faucet shank.
Mounting the Unit
1. Locate best position for mounting unit undersink near faucet. Mark mounting bracket screw locations using mounting bracket
(2568) as a template. NOTE: LEAVE MINIMUM OF 5 INCHES CLEARANCE BELOW SUMPS FOR REMOVAL OF
CARTRIDGES FOR CLEANING AND REPLACEMENT. THE HIGHER AND CLOSER TO THE FRONT YOU MOUNT THE
UNIT THE BETTER FOR REGULAR MAINTENANCE.
Fig. 1
Fig. 2
1.

2. Partially screw the 3 mounting bracket screws into screw locations. Install mounting bracket and head assembly over screw
heads and tighten screws. Note: If wall is too thin to accept screws then use round head nuts and bolts (not supplied) to
mount bracket.
Connecting the Faucet
Measure and cut a length from plastic tubing (1009-0) to connect faucet to the OUTLET fitting
(2554). Make sure to leave enough tube for step 6. Slide compression nut (720-0) and sleeve
(721-1) onto tube and put tube insert (722-0) into tube as shown in Fig. 3. Push tube into end
of faucet adaptor (1040-15) and hold firmly in place. Now tighten nut securely with a wrench.
Connect the other end of tubing to OUTLET fitting (2554) as shown in Fig. 2.
Acculink™ Fittings and Tubes (See Fig. 2)
To ensure an optimal seal tubing should be cut straight. An angled cut or distortion of the
tubing will not provide an efficient seal and may cause leaks. To install the 3/8” tube (1009-0),
mark it 3/4” from the end then push it firmly 3/4” through the collet, past the o-ring until it
seats on the tube stop. To remove the tube, push in the collet with two fingers on each side of
the tube and pull out the tube.
Installing the Self-Piercing Saddle Valve
The self-piercing saddle valve (1008-0) can be installed on copper or rigid plastic pipe of 3/8" to 3/4" diameter. (Not recom-
mended for flexible plastic pipe). Note: If your cold water line is other than described, use fittings that adapt the pipe size to 3/8"
compression (not included).
IMPORTANT: Orient saddle valve with outlet pointing towards INLET fitting (2553) so that remaining length of tube will reach
and will not have any kinks.
1. Back off handle on saddle valve to retract piercing tip. With rubber gasket in a fixed position clamp entire assembly to pipe
using bolts provided. Tighten bolts, keeping brackets parallel until rubber gasket is firmly compressed.CAUTION: DO NOT
OVERTIGHTEN.
2. Measure and cut remaining length of plastic tubing to connect cold water line to INLET fitting (2553). Slide compression nut
(720-0) and sleeve (721-1) onto tube and put brass tube insert (722-0) into tube as shown in Fig. 3. Push tube into end of
saddle clamp fitting (1008-0) and hold firmly in place. Securely tighten the compression nut while holding other end of fitting
with a wrench. Connect other end of tubing to INLET fitting (2553) as shown in Fig.2.
Starting Up
3. Remove wrapping from carbon cartridge (CF2), Lead cartridge (LR1) and ceramic cartridge (1M). Push open end (blue end
cap) of CF2 over boss of white head (inlet side), then push open end (green end cap) of LR1 cartridge over middle head
boss. To replace sump, align the sump grooves with inlet head (2501)and middle head lugs and push straight up onto the
head. Turn the sump 1/8 turn to right to fully to stop (lock position). Insert 1M cartridge with adaptor (2560) into the third
(outlet) head by pushing upwards into head boss and twisting gently at the same time. Push sump straight up gently onto
head and turn 1/8 turn to right fully to stop (lock position). Note: Bottom of sump has 4 guides to contain 1M cartridge. Sump
will not lock unless bottom of cartridge is between guides.
4. Tilt faucet handle up to constant on position.
5. Turn on water flow from cold water pipe to filter.
6. Turn saddle valve clockwise until handle is seated. YOU HAVE NOW PIERCED THE PIPE AND CLOSED THE VALVE.
Now turn valve counter clockwise back to open which starts water flow. For maximum flow, turn handle out all the way.
7. Allow water to run for few minutes to flush carbon fines from the ceramic cartridge. Adjust saddle valve so flow rate is 3/4
gallon/minute with faucet fully on.
8. Close faucet and check all connections for leaks. Carefully retighten any leaking fittings. It is a good idea to check the unit a
few times for slow leaks shortly after installation.
9. Flushing and conditioning: Allow water to flow for 10 minutes to flush unit then close faucet and allow unit to sit
overnight to condition. In the morning flush unit briefly before beginning service.
YOUR UNIT IS NOW IN OPERATION.
Note: In some cases with low water pressure, the OUTLET sump may only partially fill due to an air block. If this
happens, turn off faucet and press top vent button until water level rises past the sealing point on sump.
Note: Some carbon fines may persist for several days. These are harmless and frequent running of the unit will clear
them more quickly. Running the unit for extended periods of time will NOT help.
Cartridge Cleaning/Replacement Schedule
For most satisfactory operation, replace Carbon Cartridge (CF2), Lead Cartridge (LR1) and clean Ceramic Cartridge
(1M) every 6 months. Replace ceramic cartridge every 12 months or when cartridge gauge (703-4) can be passed over the width
of the ceramic. Note: Cartridges may require more frequent replacement if water contains excessive sediment. Clean ceramic
whenever flow rate slows to an unacceptable level.
Cleaning 1M Ceramic Cartridge
1. Close saddle valve all the way and open faucet to relieve pressure in filter. Press vent buttons on top of all heads.
2. Turn sump 1/8th turn to left and lower to remove and at same time remove ceramic cartridge by
twisting and gently pulling downwards. Do not remove cartridge by unscrewing from adaptor
(2560). Transfer cartridge and sump to sink and dump water.
Fig 3.
2.

3. To clean ceramic, (Note: Please wear rubber gloves) hold cartridge in palm of hand with nozzle up and gently scrub entire
surface with abrasive screen cleaner (811-0) provided under running water until light colour of ceramic returns. Do not allow
water to enter nozzle opening.DO NOT USE SOAP OR DETERGENTS. Scrubbing removes trapped particulates along with
part of the ceramic.
4. Insert ceramic cartridge with adaptor (2560) back into head boss. Replace sump and turn 1/8 turn to right fully to stop (lock
position). Note: Bottom of sump has 4 guides to contain 1M cartridge. Sump will not lock unless bottom of cartridge is
between guides.
5. Open water flow then open faucet until all trapped air has escaped. If air remains in ceramic housing, turn off faucet and
press top vent button until water level rises past sealing point on sump.
Replacing CF2, LR1 Cartridge - Every 6 months or 375 US Gallon (1419 Liters)
1. Close saddle valve off and open faucet to relieve pressure in filter. Press vent buttons on top of both heads.
2. Remove right sump and lower and at same time remove carbon cartridge by twisting and gently pulling downwards. Transfer
cartridge and sump to sink and dump water. Do the same for the middle housing and the LR1 cartridge.
3. Insert new CF2 & LR1 cartridges onto head boss's and replace and lock sumps. Start water flow.
4. Turn on faucet until trapped air has escaped. If air remains in housing, turn off faucet and press top vent button until water
level rises past sealing point on sump. Note: Some fines from carbon cartridge may be flushed onto ceramic cartridge. These
are harmless and are removed with next cleaning.
Replacing 1M Ceramic Cartridge - Every 12 months or 1000 US gallon (3785 Liters)
1. Follow steps 1 & 2 above to remove sump and ceramic cartridge only.
2. REMOVE CARTRIDGE ADAPTOR (2560) FROM OLD CARTRIDGE. Thread adaptor onto new cartridge. Take care not to
cross thread. Wipe any accumulated dirt from head boss before inserting new cartridge.
3. Replace cartridge by twisting and pushing adaptor up gently on head boss. Replace and lock sump. Open saddle valve to start
water flow.
4. Turn on faucet until trapped air and carbon fines are flushed. If air remains in ceramic housing, turn off faucet and press top
vent button until water level rises past sealing point on sump.
MAINTENANCE / CAUTIONS
Caution: If your unit is not used in winter, or will be subject to freezing temperatures, drain unit and remove cartridges from
sumps. Place cartridges in sink or on a paper towel to dry, which will occur in several days.
Note: Lubricate Head O-rings (2502) at least once a year and when draining for winter. Use food grade silicone grease (i.e. Dow
111 compound) or any other non petroleum lubricant. Water conditions can be hard on rubber seals. Head O-rings (2502) should
be replaced at least every two years. This is recommended to minimize wear and tear and prevent leakage.
Caution: Due to a limited product service life and to prevent costly repairs or possible water damage, we strongly recommend
that sumps (#520) be replaced every 5 years. If sumps of your filter unit have been used for more than this period, replace
immediately. Date the bottom of any new sump to indicate next replacement date.
Do Not clean housing with organic solvents such as those found in sprays for cleaning products or insecticides as these may
cause cracking or crazing and lead to failure and leakage.
Protect filter from direct sunlight. Not intended for outdoor use.
Note: For cold water use only.
TROUBLESHOOTING GUIDE
Problem Possible Cause/Solution
1. Sump is difficult to remove - Unit may still be under pressure. Close saddle valve and
open faucet to relieve pressure. Then try again.
- Head O-ring may be stuck. To break the seal, push up on
the sump before turning to unlock.
2. Leak at Head O-ring - O-ring may be dry or cracked due to age. Remove sump,
cartridge and O-ring. Lubricate O-ring with food grade
Silicone (i.e. Dow 111 Compound) or non petroleum
lubricant and reinstall. If seal still leaks, replace it.
3. Leak at Vent Button - Vent O-ring is not seating properly or is dry or cracked.
Press vent button several times to re-seat vent o-ring.
If O-ring still leaking, contact Envirogard for vent O-ring
replacement kit.
4. Flow rate is very slow after installation of unit - Call Envirogard to review installation procedure.
3.

Parts Lists
Part Name Part No. Qty
Activated Carbon Cartridge
Lead Carbon Cartridge
Ceramic Cartridge
Cartridge O-ring
Sump
Ceramic Cartridge Gauge
3/8” Compression Nut
3/8” Compression Sleeve
3/8” Brass Tube Insert
Cleaning Pad
3/8” x 48” plastic tube
Bracket Mounting Screws
Faucet Assembly Complete
Ceramic Disk Assembly
Handle
Spout O-ring
Spout
Escutcheon Plate
Escutcheon Washer
Locating Washer
Lock Washer
Lock nut
3/8” Adapter
3/8” Adapter washer
Head O-Ring
Vent Pin Assembly
3/8” MPT Nipple
3/8”x3/8” Acculink™ Fitting 90°
3/8”x3/8” Acculink™ Fitting Straight
Ceramic Cartridge Adaptor
UCS3 Triple Head Assembly Complete
Bracket c/w mounting Screws
CF2
LR1
1M
517
520
703-4
720-0
721-1
722-0
811-0
1009-0
1011-0
1040-0
1040-2
1040-6
1040-7
1040-8
1040-9
1040-10
1040-12
1040-13
1040-14
1040-15
1040-16
2502
2505
2550
2553
2554
2560
2569
2570
1
1
1
1
3
1
2
2
2
1
1
3
1
1
1
2
1
1
1
1
1
1
1
1
3
3
2
1
1
1
1
1
1008-0
720-0
721-1
722-0
703-4
811-0
2553
2554
2570
2550 2550
520
CF2
LR1
1M
Inlet
Outlet
1009-0
1009-0
1011-0
2505 2505 2505
Triple Head Assembly
Complete 2569
2502
720-0
721-1
722-0
1040-15
1040-16
1040-14
1040-13
1040-12
1040-7
1040-8
1040-10
Counter Top
1040-9
1040-2
1040-5
1040-6
Thank you for purchasing one of our water filters. We are committed to ensuring that you are totally satisfied. If you
have any problems, don’t go back to the store, please contact us !
Help Line: 1-800-667-8072 Toronto & Area: (905) 884-9388
Web Site: www.rainfresh.ca
ENVIROGARD PRODUCTS LIMITED
446 MAJOR MACKENZIE DR. E., UNIT 6, RICHMOND HILL, ON L4C 1J2 CANADA
P.O. BOX 64, RICHMOND HILL, ON L4C 4X9 CANADA
© COPYRIGHT • ENVIROGARD PRODUCTS LIMITED 2010 • ALL RIGHTS RESERVED
2578 - UCS3 - Feb/10
Limited 5 Year Warranty
Envirogard system housings are warranted, to the original Consumer purchaser/owner, for a period of five (5) years, from the date of purchase, against defects in materials or workman-
ship. O-rings, faucet and installation fittings are warranted for a period of one (1) year from the original date of consumer purchase. The Companies obligation under this warranty shall
consist of repair, replacement or credit, at its option, of any part found by the Company inspection to be defective, provided that the product has not been misused, abused, altered or
damaged as determined by the Company and provided that only approved Envirogard/Rainfresh replacement cartridges have been used in the housings. This warranty does NOT apply
to the replacement cartridge(s), which by nature will diminish in performance through normal use and require(s) regular replacement. This warranty does NOT cover, and is intended to
exclude, any liability on the part of Envirogard for any incidental damages, consequential damages, labour charges or any other costs incurred in connection with the purchase, installa-
tion, use, maintenance or repair or the water filter whether under this warranty or any other warranty implied by law. Some provinces/states do not allow the exclusion of incidental or
consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary from
province to province/state to state. This warranty applies only to water filters/systems purchased in Canada or the U.S.A.
System tested and certified by CSA International to CSA standardB483.1, to NSF/ANSI Standard 53 for reduction of Lead,
Volatile Organic Compounds (VOC), Cysts (e.g. Cryptosporidium & Giardia), Lindane and to NSF/ANSI Standard 42 for reduction
of chlorine, taste & odour
The standards referenced above evaluate products for use with disinfected waters.
Additional testing and verification for reduction of bacteria, cyst and particulates performed by independant laboratory. See Performance Data Sheet for details.
$RINKING7ATER
Autres manuels pour UCS3
1
Table des matières
Manuels Équipements de cuisine et de salle de bain populaires d'autres marques

Alpha Bidet
Alpha Bidet Alpha One Manuel utilisateur

InSinkErator
InSinkErator H/HC3300 Manuel d'installation

Clou
Clou Xo type 1 Manuel utilisateur

Kohler
Kohler Contra 26448T-4 Manuel utilisateur

Grohe
Grohe Bridgeford 20 158 Manuel utilisateur

Hans Grohe
Hans Grohe Croma Select S 180 Showerpipe EcoSmart... Manuel utilisateur